Publications and source records attributed to B Naegeli.

11 recordsLinked to original sources

[Acute myocardial infarct in Switzerland: results from the PIMICS Heart Infarct Register. PIMICS Project (Prospective Ischemia Myocardial Infarction Captopril Survey)].

The aim of the PIMICS project was to create, for the first time in Switzerland, a registry of data concerning epidemiology and therapy in patients hospitalised for acute myocardial infarction covering all regions of the country. During 1995/96 73 Swiss hospitals of all categories took part in the PIMICS project. The ratio between males and females in the 3877 registered patients was 2.6:1 (2791 men vs. 1086 women). Female patients were significantly older than males (70.4 +/- 12.0 years vs. 63.4 +/- 12.6 years; p < 0.0001). The prevalence of risk factors differed between men and women: significantly more women had hypertension or diabetes, whereas smoking was more prevalent in males. The median delay between onset of symptoms and arrival at the hospital was 5.5 hours. Thrombolysis and primary angioplasty were more frequently performed in men (40.4% vs. 31.2% in women, p < 0.0001, and 5.7% in men vs. 3.5% in women, p = 0.005 respectively). During the acute phase males were treated more frequently with betablockers. The overall in-hospital mortality was 9.1%. It was significantly higher in female patients (13.5% vs. 7.4% in men; p < 0.0001) and in patients with reinfarction (14.5% vs. 7.1%; p < 0.0001). The mean hospital stay was 12.6 +/- 5.3 days. Only 7.7% of all patients with acute myocardial infarction were discharged within 6 days. At discharge, 51.7% were treated with betablockers and 69.3% with aspirin; 44.8% received ACE-inhibitors and only 13.8% lipid-lowering drugs. Follow-up measures such as coronary angiography and/or angioplasty or bypass surgery were performed significantly more often in males (45.0% vs. 32.9%; p < 0.0001). Likewise, men were more frequently assigned to a rehabilitation program than women (38.2% vs. 32.9%; p = 0.0004). The pre-hospital delay in patients with acute myocardial infarction remains too long. Primary and secondary prevention should be intensified in high risk groups, particularly in females. Thrombolysis and primary angioplasty as mainstays of treatment in acute myocardial infarction are generally used too sparingly, especially in women. With such measures the hospital stay could be shortened further.

Adult

Intermittent pacemaker dysfunction caused by digital mobile telephones.

OBJECTIVES: This study was designed to evaluate possible interactions between digital mobile telephones and implanted pacemakers. BACKGROUND: Electromagnetic fields may interfere with normal pacemaker function. Development of bipolar sensing leads and modern noise filtering techniques have lessened this problem. However, it remains unclear whether these features also protect from high frequency noise arising from digital cellular phones. METHODS: In 39 patients with an implanted pacemaker (14 dual-chamber [DDD], 8 atrial-synchronized ventricular-inhibited [VDD(R)] and 17 ventricular-inhibited [VVI(R)] pacemakers), four mobile phones with different levels of power output (2 and 8 W) were tested in the standby, dialing and operating mode. During continuous electrocardiographic monitoring, 672 tests were performed in each mode with the phones positioned over the pulse generator, the atrial and the ventricular electrode tip. The tests were carried out at different sensitivity settings and, where possible, in the unipolar and bipolar pacing modes as well. RESULTS: In 7 (18%) of 39 patients, a reproducible interference was induced during 26 (3.9%) of 672 tests with the operating phones in close proximity (<10 cm) to the pacemaker. In 22 dual-chamber (14 DDD, 8 VDD) pacemakers, atrial triggering occurred in 7 (2.8%) of 248 and ventricular inhibition in 5 (2.8%) of 176 tests. In 17 VVI(R) systems, pacemaker inhibition was induced in 14 (5.6%) of 248 tests. Interference was more likely to occur at higher power output of the phone and at maximal sensitivity of the pacemakers (maximal vs. nominal sensitivity, 6% vs. 1.8% positive test results, p = 0.009). When the bipolar and unipolar pacing modes were compared in the same patients, ventricular inhibition was induced only in the unipolar mode (12.5% positive test results, p = 0.0003). CONCLUSION: Digital mobile phones in close proximity to implanted pacemakers may cause intermittent pacemaker dysfunction with inappropriate ventricular tracking and potentially dangerous pacemaker inhibition.

Aged

VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.

BACKGROUND: Recent studies have shown that the atrial signal can reliably be sensed for VDD(R) pacing via atrial floating electrodes incorporated in a single-pass lead. However, there remains concern about the long-term stability of atrial sensing and proper VDD function under real-life conditions. This study investigated the long-term reliability of atrial sensing and atrioventricular synchronous pacing using a new single lead VDD(R) pacing system. METHODS AND RESULTS: In 20 consecutive patients (ages 71 +/- 14 years) with normal sinus node function and high-degree heart block, a single lead VDD(R) pacemaker (Unity, Intermedics) was implanted. Atrial sensing was studied at implantation, at discharge, and at 1, 3, 6, 12, and 18 months of follow-up. At implant, the measured P wave amplitude was 2.3 +/- 1.2 mV. By telemetry, the atrial sensing threshold was 0.79 +/- 0.41 mV at discharge, 0.75 +/- 0.43 mV at 1 month, 0.73 +/- 0.43 mV at 3 months, 0.76 +/- 0.41 mV at 6 months, 0.79 +/- 0.41 mV at 12 months, and 0.77 +/- 0.35 mV at 18 months of follow-up (P = NS). Appropriate VDD pacing was assessed by the percentage of correct atrial synchronization (PAS = atrial triggered ventricular paced complexes divided by total number of ventricular paced complexes) during repeated Holters. PAS was 99.99% +/- 0.01% at 1 month, 99.99% +/- 0.02% at 3 months, and 99.98% +/- 0.05% at 12 months of follow-up (P = NS). No atrial oversensing with inappropriate ventricular pacing was observed, neither during isometric arm exercise testing nor spontaneously during Holter monitoring. CONCLUSION: The long-term stability of atrial sensing with almost 100% correct atrial synchronous tracking and the lack of inappropriate pacing due to atrial oversensing make the new Unity VDD(R) system a highly reliable single lead pacing system. In view of the lower costs and the ease of single lead implantation, this system may offer an interesting alternative to DDD pacemakers in patients with normal sinus node function.

Aged

Prolonged decrease in heart rate variability after elective hip arthroplasty.

The pattern of postoperative heart rate variability may provide insight into the response of the autonomic nervous system to anaesthesia and surgery. We have obtained spectral (fast Fourier transform) and non-spectral indices of heart rate variability from electrocardiographic recordings, sampled during continuous perioperative Holter monitoring in 15 otherwise healthy patients with an uncomplicated postoperative course, undergoing elective hip arthroplasty with either spinal or general anaesthesia. In both groups, total spectral energy (0.01-1 Hz), low-frequency spectral energy (0.01-0.15 Hz) and high-frequency spectral energy (0.15-0.40 Hz) decreased after surgery to 32% (95% confidence interval (CI) 10.5; P < 0.01), 29% (95% CI 12.5; P < 0.01) and 33% (95% CI 12.5; P < 0.01) of their preoperative values, respectively, and these indices remained suppressed for up to 5 days. Non-spectral indices decreased to a similar extent. These findings indicate a substantial and prolonged postoperative decrease in both parasympathetic and sympathetic influence on the sinus node.

Aged