PubMed Health⌕ Search

Biomedical subjects

B O'Quinn

Publications and source records attributed to B O'Quinn.

3 recordsLinked to original sources

Thin-film thermoelectric devices with high room-temperature figures of merit.

Thermoelectric materials are of interest for applications as heat pumps and power generators. The performance of thermoelectric devices is quantified by a figure of merit, ZT, where Z is a measure of a material's thermoelectric properties and T is the absolute temperature. A material with a figure of merit of around unity was first reported over four decades ago, but since then-despite investigation of various approaches-there has been only modest progress in finding materials with enhanced ZT values at room temperature. Here we report thin-film thermoelectric materials that demonstrate a significant enhancement in ZT at 300 K, compared to state-of-the-art bulk Bi2Te3 alloys. This amounts to a maximum observed factor of approximately 2.4 for our p-type Bi2Te3/Sb2Te3 superlattice devices. The enhancement is achieved by controlling the transport of phonons and electrons in the superlattices. Preliminary devices exhibit significant cooling (32 K at around room temperature) and the potential to pump a heat flux of up to 700 W cm-2; the localized cooling and heating occurs some 23,000 times faster than in bulk devices. We anticipate that the combination of performance, power density and speed achieved in these materials will lead to diverse technological applications: for example, in thermochemistry-on-a-chip, DNA microarrays, fibre-optic switches and microelectrothermal systems.

Journal Article↗

Large DNA fragment sizing by flow cytometry: application to the characterization of P1 artificial chromosome (PAC) clones.

A flow cytometry-based, ultrasensitive fluorescence detection technique is used to size individual DNA fragments up to 167 kb in length. Application of this technology to the sizing of P1 artificial chromosomes (PACs) in both linear and supercoiled forms is described. It is demonstrated that this method is well suited to characterizing PAC/BAC clones and will be very useful for the analysis of large insert libraries. Fluorescence bursts are recorded as individual, dye stained DNA fragments pass through a low power, focused, continuous laser beam. The magnitudes of the fluorescence bursts are linearly proportional to the lengths of the DNA fragments. The histograms of the burst sizes are generated in <3 min with <1 pg of DNA. Results on linear fragments are consistent with those obtained by pulsed-field gel electrophoresis. In comparison with pulsed-field gel electrophoresis, sizing of large DNA fragments by this approach is more accurate, much faster, requires much less DNA, and is independent of the DNA conformation.

Chromosomes↗

Classification of nasal defects: a practical guide for reconstruction.

Nasal defects are among the most complicated problems frequently facing the otolaryngologists--head and neck surgeon. The complex role of the nasal structure and its anatomy makes a practical guide for reconstruction particularly attractive. The nose, as a unique facial component, must ideally perform important airway functions, while also having an acceptable appearance. A range of reconstructive problems from simple defects to total nasal loss is addressed.

Female↗