PubMed HealthSearch

Biomedical subjects

B Oeseburg

Publications and source records attributed to B Oeseburg.

At least 19 recordsLinked to original sources

The effect of blood transfusion and haemodilution on cerebral oxygenation and haemodynamics in newborn infants investigated by near infrared spectrophotometry.

UNLABELLED: The objective of this study was to investigate the influence of blood transfusion and haemodilution on cerebral oxygenation and haemodynamics in relation to changes in cerebral blood flow velocity (CBFV) and other relevant physiological variables in newborn infants. Thirteen preterm infants with anaemia (haematocrit < 0.33) and ten infants with polycythaemia (haematocrit > 0.65) were studied during blood transfusion and haemodilution respectively using adult red blood cells and partial plasma exchange transfusion. Changes in cerebral concentrations of oxyhaemoglobin (cO2Hb), deoxyhaemoglobin (cHHb), total haemoglobin (ctHb), (oxidized-reduced) cytochrome aa3 (cCyt.-aa3) were continuously measured using near infrared spectrophotometry throughout the whole procedure. Simultaneously, changes of mean CBFV in the internal carotid artery were continuously measured using pulsed Doppler ultrasound. Heart rate, transcutaneous partial pressure of oxygen and carbon dioxide, and arterial O2 saturation were continuously and simultaneously measured. Blood transfusion resulted in increase of cO2Hb, cHHb, ctHb and red cell transport (product of CBFV and haematocrit), whereas CBFV decreased. The increase of cO2Hb exceeded that of cHHb, reflecting improvement of cerebral O2 supply. Haemodilution resulted in a decrease of cO2Hb, cHHb and ctHb, whereas CBFV increased. Red cell transport was unchanged. The decrease of cO2Hb exceeded that of cHHb, reflecting decreased cerebral O2 supply. cCyt.aa3 decreased after blood transfusion and remained unchanged after haemodilution, but the reliability of these results is uncertain. With the exception of a small, but significant increase in transcutaneous partial pressure of oxygen after blood transfusion, the other variables showed no changes. Each blood withdrawal during exchange transfusion resulted in only a significant increase in heart rate without changes in the other variables measured, suggesting unchanged cerebral perfusion. CONCLUSION: In newborn infants blood transfusion in anaemia results in improvement of cerebral oxygenation, but haemodilution in polycythaemia does not improve cerebral oxygenation despite possible improvement of cerebral perfusion.

Anemia

Accuracy of fetal pulse oximetry and pitfalls in measurements.

Pulse oximetry is a technique for estimating arterial oxygen saturation continuously and non-invasively. Reflectance pulse oximetry might become useful for monitoring the fetus during labour but it is much more susceptible to all kinds of physiological variations than the well-established transmission pulse oximetry for neonatal or adult monitoring. This review focuses on the accuracy of reflectance pulse oximetry. Results of human, animal, in vitro and theoretical models indicate that factors such as; blood volume fraction differences, haematocrit, and blood flow differences are major sources for inaccurate pulse oximetry readings in the fetal arterial oxygen saturation range of 10-80%. These factors cannot be overcome by systems using two wavelengths sensors with the 660/890 or 940 nm combination. Reported precision values (S.D. of difference between pulse oximeter and blood sample saturation) range between 2.5 and 12.9% for various 660 nm sensors. Most sensors were tested only once with a limited number of animals. A new 735/890 nm sensor (Nellcor Puritan Bennett) demonstrates a promising accuracy (precision around 5%) in two studies. Various other sensors have also been developed, but are not or scarcely evaluated. Without thorough establishment of the reliability of this technique, clinical fetal oxygen saturation data are still of limited value.

Animals

Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.

OBJECTIVE: A new reflectance pulse oximetry sensor, developed for intrapartum estimation of arterial oxygen saturation (SaO2), was calibrated and evaluated. The sensor contains two light emitting diodes of 735 and 890 nm, and a photodetector at a distance of 14 mm from both light emitting diodes. METHODS: In seven Yorkshire/Hampshire piglets, the reflectance sensor (Nellcor Puritan Bennett Inc.) was calibrated using blood sample SaO2 values. The resulting calibration line was evaluated in four Dutch piglets, by comparing pulse oximetry saturation readings (SpO2) with blood sample and intravascular fiberoptic oximetry SaO2 values. Several reflectance sensors were fixed on each animal. Desaturation levels were obtained by changing the gas mixture of oxygen/ nitrous oxide via a tracheal catheter. RESULTS: In the Yorkshire/ Hampshire piglets, the standard deviation of difference (SpO2-SaO2) was 4.7% (n = 364), over an SaO2 range of 17% to 100%. In the Dutch piglets, the mean difference (SpO2-SaO2) was -1.6% and the standard deviation of difference was 5.4%, over the same SaO2 range (n = 254). Comparisons of continuous recordings of reflectance SpO2 and fiberoptic SaO2 revealed variation in individual regression lines. CONCLUSIONS: This new 735/890 nm reflectance sensor demonstrates acceptable accuracy in piglets. A further evaluation during labor should assess its feasibility for fetal surveillance.

Animals

Cerebral and circulatory haemodynamics before vasovagal syncope induced by orthostatic stress.

Vasovagal syncope is usually described as a sudden and transient loss of consciousness that resolves spontaneously. Cardiocirculatory changes are well described during and before syncope. However, changes in the cerebral oxygenation are not well defined. In this study, near-infrared spectroscopy (NIRS) was used to assess the cerebral oxygenation directly during 80 degree head-up (HU) tilt. To simulate central hypovolaemia, 500 ml of blood was drawn from each of 10 healthy subjects. Oxygenation index (OI) was defined as the difference between oxy- and deoxyhaemoglobin concentration. Blood pressure, heart rate and cardiac output were monitored using a finger plethysmographic device. The protocol was divided into two stages, each consisting of a 15-min stabilization period in the supine (SUP) position, 15 min in HU position and another 10 min in SUP position. Between both stages, blood was drawn from the subject. Haemoglobin concentration and haematocrit were measured before and 30 min after withdrawal of blood. No compensatory haemodilution was observed. During HU position in the second stage, six subjects showed signs of presyncope (F) and four did not (NF). A significant difference between F and NF was found in the observation that, before fainting, the OI of F showed a steady and significant (P = 0.02) decrease (-1.4 +/- 0.5 microM min-1) compared with NF (-0.18 +/- 0.16 microM min-1). This indicates that the onset of (pre)syncope is preceded by a mismatch between oxygen demand and oxygen supply in the cerebrum. Using NIRS enabled us to monitor this mismatch and to predict the onset of a syncope before clear signs in cardiocirculatory variables were visible.

Adult

Muscle glycogen recovery after exercise during glucose and fructose intake monitored by 13C-NMR.

The purpose of this study was to examine muscle glycogen recovery with glucose feeding (GF) compared with fructose feeding (FF) during the first 8 h after partial glycogen depletion using 13C-nuclear magnetic resonance (NMR) on a clinical 1.5-TNMR system. After measurement of the glycogen concentration of the vastus lateralis (VL) muscle in seven male subjects, glycogen stores of the VL were depleted by bicycle exercise. During 8 h after completion of exercise, subjects were orally given either GF or FF while the glycogen content of the VL was monitored by 13C-NMR spectroscopy every second hour. The muscular glycogen concentration was expressed as percentage of the glycogen concentration measured before exercise. The glycogen recovery rate during GF (4.2 +/- 0.2%/h) was significantly higher (P < 0.05) compared with values during FF (2.2 +/- 0.3%/h). This study shows that 1) muscle glycogen levels are perceptible by 13 C-NMR spectroscopy at 1.5 T and 2) the glycogen restoration rate is higher after GF compared with after FF.

Adult

The influence of extracorporeal membrane oxygenation on cerebral oxygenation and hemodynamics in normoxemic and hypoxemic piglets.

The objective of this study was to compare the effect of extracorporeal membrane oxygenation (ECMO) on cerebral oxygenation and hemodynamics in normoxemic and hypoxemic piglets. Six hypoxemic and six normoxemic piglets were put on venoarterial ECMO after cannulation of the right common carotid artery and external jugular vein with careful priming to avoid hemodilution. Changes in cerebral concentrations of oxyhemoglobin (cO2Hb), deoxyhemoglobin (cHHb), (oxidized-reduced) cytochrome aa3 (cCyt.aa3), and blood volume (CBV) were continuously measured by near infrared spectrophotometry. Heart rate, arterial O2 saturation (SaO2), arterial blood pressure, pulsatility ratio of systemic circulation (calculated as systolic-diastolic/mean arterial blood pressure), central venous pressure, intracranial pressure, and left common carotid artery blood flow (LCaBF) were simultaneously measured. We found that the cannulation procedure resulted in increased CBV, cHHb, and LCaBF in both groups. At 60 and 120 min after starting ECMO, the values of cO2Hb, CBV, and LCaBF in both groups were significantly higher than precannulation values, while the pulsatility ratio decreased. In the hypoxemic groups cHHb decreased and SaO2 increased as well. No significant changes of other variables were found. Between hypoxemic and normoxemic groups no significant differences in the response of CBV and LCaBF at 60 and 120 min were found. We conclude that in piglets cannulation for ECMO resulted in cerebral venous congestion and compensated increase in LCaBF. After starting ECMO, the cerebral O2 supply increased due to increased arterial O2 content. It was accompanied by similar increase of CBV in both groups, probably as a result of hyperperfusion, which seems to be related to the ECMO procedure itself.

Animals

Transmission pulse oximetry in the fetal lamb: is there a universal calibration?

Transmission pulse oximetry is widely used for oxygen monitoring. The use of pulse oximeters is steadily expanding toward situations with low arterial oxygen saturation (Sao2) values. Therefore, we evaluated transmission pulse oximetry in the unanesthetized fetal lamb at low Sao2 levels. In seven fetal lambs, fetal hypoxemia was induced by occlusion of the maternal common iliac artery, four days after the instrumentation of the animal. Two Nellcor prototype transmission Y-sensors (light emitting diodes: 660 and 890 nm) were applied, one around a forelimb muscle and one around a skinfold in the neck, and were connected to Nellcor pulse oximeters. The pulse oximeter was calibrated for the skin measurements. Pulse oximeter saturation readings (Spo2) were compared with sample Sao2 values, over an Sao2 range of 13 to 63%. For the neck sensor the SD of the difference was 5.0% (n = 101). For the muscle sensor the mean difference was 19.5% and the SD of the difference was 5.9% (n = 206). Regression analysis showed a different calibration line for the muscle sensor with the equation: Spo2 = 0.92 x Sao2 + 21.90. Continuous recordings were obtained both from the forelimb muscle and from the neck, but the recordings from the neck showed a substantial loss of signal during the hypoxemia period. We conclude that transmission pulse oximetry is less accurate below an Sao2 of 70% in fetal lambs than above 70% Sao2. At these low levels of Sao2, pulse oximeters may need to be constructed with different calibration lines for various application positions of the body.

Animals

Maximal oxygen uptake in 153 elderly Dutch people (69-87 years) who participated in the 1993 Nijmegen 4-day march.

There are no studies on oxygen uptake of groups of physically active subjects aged over 70. This study describes the maximal oxygen uptake (VO2max) of 153 elderly people who completed the Nijmegen annual 4-day march (at least 30 km.day-1) in 1993. A total of 97 men with a mean age of 76.7 (SD 4.6) and 56 women with a mean age of 72.8 (SD 3.6) years participated in the study. The VO2max was determined using incremental cycle ergometry; 91 men and 49 women completed a maximal exercise test. Criteria for maximal performance were respiratory exchange ratio equal to or greater than 1.00, vertilatory equivalent for oxygen equal to or greater than 30.00 and maximal heart rate equal to or greater than (beats.min-1) 210 minus age (years). Mean maximal power output was 148.2 (SD 27.2) W and 120.4 (SD 20.5) W, mean VO2max.body mass-1 was 26.8 (SD 4.9) ml.kg-1.min-1 and 24.6 (SD 4.7) ml.kg-1.min-1, mean maximal heart rate was 152 (SD 18), and 157 (SD 14) beats.min-1 in men and women respectively. The mean VO2max.body mass-1 was about 20% higher than reported in other studies on subjects over 70 years of age. Mean maximal heart rate was about 10 beats.min-1 higher than predicted from the equation 220-age. The negative effect of chronic disease on VO2max.body mass-1 was smaller than in a sedentary reference population. The mean decline in VO2max.body mass-1 with age was 0.46 and 0.38 ml.kg-1.min-1 per year in the men and women respectively, which is the same rate as found in younger subjects. It was concluded that regular exercise might substantially increase aerobic power in the physically active elderly, even when they have chronic disease, and that it is unlikely that there is an accelerated loss of aerobic power in physically active elderly people aged over 70 year.

Aged

The effect of pulsating arteries on reflectance pulse oximetry: measurements in adults and neonates.

OBJECTIVE: The objective of our study was to describe the results from human experiments during normoxia that demonstrate the effect of pulsating arteries on the measured arterial oxygen saturation (SpO2) using a reflectance pulse oximeter sensor. METHODS: In 6 healthy adults and 7 healthy neonates, a Nellcor reflection sensor (FS-10 oxisensor, Nellcor, Inc., Pleasanton, CA) was placed in three different positions: (1) on the forehead, (2) on the temporal area, with the photodiode placed over the superficial temporal artery, and (3) on the temporal area, with the light-emitting diodes (LEDs) placed over the superficial temporal artery. RESULTS: Placement of the sensor in position 2 resulted in a significantly lower SpO2 reading, compared to sensor position 1: 5.8% (p < 0.01) lower for adults and 7.5% (p < 0.01) lower for neonates. Placement of the sensor in position 3 resulted in significantly larger plethysmographic signals, compared to sensor position 1; but, the Spo2 readings were alike. CONCLUSIONS: Pulsating arteries can affect the reliability of reflection pulse oximetry. Depending on the position of the sensor, a falsely low Spo2 value can be observed.

Adult

Arterial oxygen saturation in relation to metabolic acidosis in fetal lambs.

OBJECTIVE: We studied the relationship between preductal arterial oxygen saturation and metabolic acidosis in 18 chronically instrumented fetal lambs (gestational age 119 to 133 days) in two experimental designs. In the first group the onset of metabolic acidosis was determined. In the second group the progression of metabolic acidosis was studied as was the cardiovascular and hormonal changes resulting from hypoxemia. STUDY DESIGN: In nine fetal lambs maternal fraction of inspired oxygen was lowered stepwise by increasing flows of nitrogen delivered into the trachea through a small indwelling catheter (group 1), and in nine fetal lambs maternal blood flow was reduced stepwise by means of a vascular occluder (group 2). RESULTS: Baseline arterial oxygen saturation values ranged from 26% to 67% with normal pH and extracellular fluid base excess values in both groups 1 and 2. In both groups pH and extracellular fluid base excess started to decrease below 30% arterial oxygen saturation, with a progressive decrease below 20% arterial oxygen saturation to an end value for pH of 7.14. In some fetal lambs pH and extracellular fluid base excess decreased initially at 20% to 30% arterial oxygen saturation and then stabilized at the lower level. Fetal heart rate in group 1 increased during hypoxemia from 155 to 179 beats/min. In group 2 baseline fetal heart rate was 153 beats/min and fell with every step change in arterial oxygen saturation but subsequently increased to 172 beats/min by the end of the period of hypoxemia. Baseline values for epinephrine, norepinephrine, dopamine, cortisol, and mean arterial pressure were not related to baseline arterial oxygen saturation levels, and each of these variables was increased at the end of hypoxemia in group 2. CONCLUSION: Preductal arterial oxygen saturation can reach values between 20% and 30% before anaerobic metabolism starts. During the progressive acidosis blood pressure was increased, which can be attributed to a strong rise in catecholamines.

Acidosis

Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.

Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As pulse oximeters are constructed for the determination of arterial oxygen saturation, they should be validated with sample oxygen saturation values and not with the oxyhaemoglobin fraction. The influence of carboxyhaemoglobin is insubstantial over an oxygen saturation range of 0% to 100%. Through the presence of methaemoglobin, pulse oximetry will give an underestimation above 70% and an overestimation below 70% oxygen saturation. The influence of fetal haemoglobin is insignificant in the neonatal use of pulse oximetry, in the range of 75% to 100% arterial oxygen saturation. However, a pulse oximeter underestimates the arterial oxygen saturation at the 25% level with 5%, if the pulse oximeter has been calibrated in human adults. Such a low level of arterial oxygen saturation can be present in the fetus during labor.

Adult

The accuracy of a fiberoptic oximeter over a wide range of arterial oxygen saturation values in piglets.

A piglet model was used to evaluate the accuracy of a fiberoptic oximeter over a wide range of arterial oxygen saturation (SaO2) values. In eight anaesthetized piglets, the inspired oxygen concentration was varied from 30% to 6% resulting in a SaO2 range from 100% to 15%. Paired data of the Opticath fiberoptic catheter, which was placed in the descending aorta, and blood sample SaO2 values assessed by a multiwavelength oximeter, were analysed. After in vitro calibration according to the manufacturer's instruction, the fiberoptic catheter started to underestimate the SaO2 below 78%, worsening towards lower SaO2 values. The overall bias was -3.4% and the precision 3.8%. An off-line fit with a non-linear model resulted in a standard deviation of residuals of 2.6%. After several in vivo calibration adjustments when the fiberoptic oximeter deviated more than 4% from the blood sample value, the bias was eliminated over the total SaO2 range and the precision was 3.7%. The Opticath fiberoptic oximeter could have an accuracy for the whole SaO2 range between 15-100% close to the accuracy of the multiwavelength oximeter, when the fiberoptic oximeter is adapted for the underestimation below 78% SaO2.

Anesthesia, General

A comparative study of two near infrared spectrophotometers for the assessment of cerebral haemodynamics.

Conventional near infrared spectroscopy (NIRS), introduced by Jöbsis in 1977, can be considered as a reliable trend monitor for cerebral oxygenation. Quantisation, however, is complex and cumbersome. Recently a relatively simple system for cerebral oximetry (INVOS 3100, Somanetics Corporation, USA) was developed, measuring the regional oxygen saturation (rSO2) in the capillary bed of the cerebrum, presented as a numerical figure for easy interpretation. In this study a comparison was made between a conventional NIRS instrument and the new INVOS instrument, in order to obtain information about sensitivity and usefulness of the INVOS system. Changes in cerebral haemodynamics were induced by a moderate decrease of the arterial oxygen saturation (SaO2) and by varying the arterial carbon dioxide level (PaCO2). This will result in a higher (hypercapnia) or lower (hypocapnia) cerebral blood flow and subsequent change of both NIRS signals and INVOS signal. Healthy volunteers were used for this study. It was found that the steady state value for rSO2 was 70 +/- 6% (mean +/- SD). During the lowering of arterial saturation a poor correlation was found between rSO2 and SaO2 (r = 0.47). Increased cerebral blood flow induced by hypercapnia was detected by both conventional NIRS and the INVOS. Decreased cerebral blood flow induced by hypocapnia could only be detected by conventional NIRS. It was concluded that due to the variation in displayed rSO2 and the high amount of averaging in the algorithm the INVOS instrument does not yet provide more information than conventional NIRS.

Adult