PubMed Health⌕ Search

Biomedical subjects

B P F Lelieveldt

Publications and source records attributed to B P F Lelieveldt.

4 recordsLinked to original sources

Accuracy of short-axis cardiac MRI automatically derived from scout acquisitions in free-breathing and breath-holding modes.

To qualitatively assess the accuracy of automated cardiovascular magnetic resonance planning procedures devised from scout acquisitions in free-breathing and breath-holding modes, to quantitatively evaluate the accuracy of the derived left ventricular volumes, mass and function and compare these parameters with the ones obtained from the manually planned acquisitions. Ten healthy volunteers underwent cardiovascular MR (CMR) acquisitions for ventricular function assessment. Short-axis data sets of the left ventricle (LV) were manually planned and generated twice in an automatic fashion. Automated planning parameters were derived from gated scout acquisitions in free-breathing and breath-holding modes. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were measured. The agreement between the manual and automatic planning methods, as well as the variability of the aforementioned measurements were assessed. The differences between two automated planning methods were also compared. The mean differences between the manual and automated CMR planning derived from gated scouts in free-breathing mode were 8.05 ml (EDV), 1.84 ml (ESV), 0.69% (EF), and 4.72 g (LVM). The comparison between manual and automated CMR planning derived from gated scouts in breath-holding mode yielded the following differences: 4.22 ml (EDV), 0.34 ml (ESV), 0.3% (EF), and -0.72 mg (LVM). The variability coefficients were 3.72 and 3.66 (EDV), 5.6 and 8.19 (ESV), 3.46 and 4.31 (EF), 6.49 and 5.20 (LVM) for the automated CMR planning methods derived from scouts in free-breathing and breath-holding modes, respectively. Automated CMR planning methods can provide accurate measurements of LV dimensions in normal subjects, and therefore may be utilized in the clinical environment to provide a cost-effective solution for functional assessment of the human cardiovascular system.

Adult↗

Parametric optimization of a model-based segmentation algorithm for cardiac MR image analysis: a grid-computing approach.

In this work we present a Grid-based optimization approach performed on a set of parameters that affects both the geometric and grey-level appearance properties of a three-dimensional model-based algorithm for cardiac MRI segmentation. The search for optimal values was assessed by a Monte Carlo procedure using computational Grid technology. A series of segmentation runs were conducted on an evaluation database comprising 30 studies at two phases of the cardiac cycle (60 datasets), using three shape models constructed by different methods. For each of these model-patient combinations, six parameters were optimized in two steps: those which affect the grey-level properties of the algorithm first and those relating to the geometrical properties, secondly. Two post-processing tasks (one for each stage) collected and processed (in total) more than 70000 retrieved result files. Qualitative and quantitative validation of the fitting results indicates that the segmentation performance was greatly improved with the tuning. Based on the experienced benefits with the use of our middleware, and foreseeing the advent of large-scale tests and applications in cardiovascular imaging, we strongly believe that the use of Grid computing technology in medical image analysis constitutes a real necessity.

Algorithms↗

Automatic segmentation and plaque characterization in atherosclerotic carotid artery MR images.

In vivo MRI provides a means to non-invasively image and assess the morphological features of atherosclerotic carotid arteries. To assess quantitatively the degree of vulnerability and the type of plaque, the contours of the lumen, outer boundary of the vessel wall and plaque components, need to be traced. Currently this is done manually, which is time-consuming and sensitive to inter- and intra-observer variability. The goal of this work was to develop an automated contour detection technique for tracing the lumen, outer boundary and plaque contours in carotid MR short-axis black-blood images. Seventeen patients with carotid atherosclerosis were imaged using high-resolution in vivo MRI, generating a total of 50 PD- and T1-weighted MR images. These images were automatically segmented using the algorithm presented in this work, which combines model-based segmentation and fuzzy clustering to detect the vessel wall, lumen and lipid core boundaries. The results demonstrate excellent correspondence between automatic and manual area measurements for lumen (r = 0.92) and outer (r = 0.91), and acceptable correspondence for fibrous cap thickness (r = 0.71). Though further optimization is required, our algorithm is a powerful tool for automatic detection of lumen and outer boundaries, and characterization of plaque in atherosclerotic vessels.

Aged↗

Multi-View Active Appearance Models: application to X-ray LV angiography and cardiac MRI.

This paper describes a Multi-View Active Appearance Model (AAM) for coherent segmentation of multiple cardiac views. Cootes' AAM framework was adapted by considering shapes and intensities from multiple views, while eliminating trivial difference in object pose in different views. This way, the coherence in organ shape and intensities between different views is modeled, and utilized during image search. The method is validated in two substantially different and novel applications: segmentation of combined end-diastolic and end-systolic left ventricular X-ray angiograms, and simultaneous segmentation of a combination of four chamber, two chamber and short-axis cardiac MR views.

Algorithms↗