PubMed Health⌕ Search

Biomedical subjects

B Packer

Publications and source records attributed to B Packer.

6 recordsLinked to original sources

Dissolution of composition B detonation residuals.

Composition B (Comp B) detonation residuals pose environmental concern to the U.S. Army because hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), a constituent, has contaminated groundwater near training ranges. To mimic their dissolution on surface soils, we dripped water at 0.51 ml/h onto individual Comp B particles (0.1-2.0 mg) collected from the detonation of 81-mm mortars. Analyses of the effluent indicate thatthe RDX and 2,4,6-trinitrotoluene (TNT) in Comp B do not dissolve independently. Rather, the relatively slow dissolution of RDX controls dissolution of the particle as a whole by limiting the exposed area of TNT. Two dissolution models, a published steady-flow model and a drop-impingement model developed here, provide good agreementwith the data using RDX parameters for time scaling. They predict dissolution times of 6-600 rainfall days for 0.01-100 mg Comp B particles exposed to 0.55 cm/h rainfall rate. These models should bracket the flow regimes for dissolution of detonation residuals on soils, but they require additional data to validate them across the range of particle sizes and rainfall rates of interest.

Environmental Exposure↗

Evaluation of a rapid latex agglutination test for detection of group B streptococci in vaginal specimens.

A rapid latex agglutination test (Bactigen Group B Streptococcus Cervical Screen) for detection of group B streptococci in cervical-vaginal specimens was evaluated using two different slide systems, the traditional serologic slide and capillary action track (Trak) slide. Culture was used as reference method. A total of 344 cervical-vaginal specimens were tested. The group B streptococci carrier rate was found by culture to be 10.8%, 56.8% of these specimens being heavily colonized. The sensitivity and specificity of the latex agglutination test in heavily colonized specimens was 95.2% and 99.3% for the serologic and track slides respectively. The overall sensitivity, including lightly colonized specimens, was 62.2%. The positive predictive value was 92% for both slide systems, and the negative predictive value 95.4% and 95.6% for the serologic and track slides respectively. The latex agglutination test, used with either slide, provides a rapid and effective method for identification of specimens heavily colonized with group B streptococci. The track slide may provide a convenient alternative to serologic slides since it does not require rotation.

Cervix Uteri↗