PubMed Health⌕ Search

Biomedical subjects

B Phelps

Publications and source records attributed to B Phelps.

9 recordsLinked to original sources

Analytical and clinical sensitivity of West Nile virus RNA screening and supplemental assays available in 2003.

BACKGROUND: Transfusion-transmitted West Nile virus (WNV) infections were first reported in 2002, which led to rapid development of investigational nucleic acid amplification tests (NAT). A study was conducted to evaluate sensitivities of WNV screening and supplemental NAT assays first employed in 2003. STUDY DESIGN AND METHODS: Twenty-five member-coded panels were distributed to NAT assay manufacturers. Panels included five pedigreed WNV standards (1, 3, 10, 30, and 100 copies/mL), 15 or 16 donor units with very-low-level viremia identified through 2003 screening, and four or five negative control samples. Samples were tested neat in 10 replicates by all assays; for NAT screening assays, 10 replicates were also performed on dilutions consistent with minipool (MP)-NAT. The viral load distribution for 142 MP-NAT yield donations was characterized, relative to the analytical sensitivity of MP-NAT systems. RESULTS: Analytical sensitivities (50% limits of detection [LoD] based on Poisson model of detection of WNV standards) for screening NAT assays ranged from 3.4 to 29 copies per mL; when diluted consistent with MP pool sizes, the 50 percent LoD of screening NAT assays was reduced to 43 to 309 copies per mL. Analytical sensitivity of supplemental assays ranged from 1.5 to 7.7 copies per mL (50% LoD). Detection of RNA in donor units varied consistent with analytical LoD of assays. Detection of low-level viremia after MP dilutions was particularly compromised for seropositive units, probably reflecting lower viral loads in the postseroconversion phase. Based on the viral load distribution of MP-NAT yield donations (median, 3519 copies/mL; range, < 50-690,000), 13 to 24 percent of units had viral loads below the 50 percent LoD of screening NAT assays run in MP-NAT format. CONCLUSION: WNV screening and supplemental assays had generally excellent analytical sensitivity, comparable to human immunodeficiency virus-1 and hepatitis C virus NAT assays. The presence of low-level viremic units during epidemic periods and the impact of MP dilutions on sensitivity, however, suggest the need for further improvements in sensitivity as well as a role for targeted individual-donation NAT in epidemic regions.

Blood Banks↗

Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even the smallest changes in lead position revealed significantly different functional results. Optimizing the pacing site with this technique allowed functional improvement up to 40% versus random pace site selection.

Cardiac Pacing, Artificial↗

Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

OBJECTIVES: Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. METHODS: Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. RESULTS: Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. CONCLUSIONS: To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

Adult↗

Failure of routine HIV-1 tests in a case involving transmission with preseroconversion blood components during the infectious window period.

CONTEXT: Current screening practices for blood donations have been successful in reducing human immunodeficiency virus (HIV) transmission through receipt of contaminated blood products. However, HIV-infected blood donations made prior to seroconversion and before high levels of viral replication occur could test negative using both serologic antigen and antibody tests. Testing based on nucleic acid amplification (NAT) is being implemented to screen for HIV-infected blood donated during this period, yet the issue of single vs minipool donation screening remains unresolved. OBJECTIVES: To determine HIV-1 genetic linkage between virus in 2 HIV-1-infected recipients of blood components and virus in the donor, who was HIV antigen and antibody negative at the time of donation; to screen the blood donor's plasma with HIV NAT assays, including those currently proposed for use in US blood donation screening. DESIGN AND SETTING: Case study conducted in October 1997 involving the Communicable Disease Centre, Singapore General Hospital, and the Singapore Blood Transfusion Service, Singapore. SUBJECTS: The blood donor and the 2 recipients of donor platelets and red blood cells. MAIN OUTCOME MEASURES: Genetic analysis of the HIV-1 p17 coding region of gag and the C2V5 region of env to determine the genetic relatedness of virus from the donor and recipients; reactivity in quantitative and qualitative assays, and reactivity in donor screening HIV NAT assays in single donation and minipool screening contexts. RESULTS: Direct DNA sequencing demonstrated identical HIV-1 subtype E viral sequences in the donor and recipients. Based on comparisons of a qualitative and quantitative assay for HIV-1 RNA levels, a low level of viremia (range, 5-39 copies/mL in plasma) was estimated to be in the donor's undiluted blood at the time of donation. Additional testing using donor-screening NAT assays showed consistent detection of HIV RNA in the undiluted donor plasma whereas detection was inconsistent at the 1:16 and 1:24 dilution levels currently used in minipool screening of blood donations in the United States. CONCLUSIONS: Transmission of HIV from a blood donor to a platelet recipient and a red blood cell recipient occurred in the preseroconversion infectious window period. The viral load in the implicated donation was estimated to be less than 40 copies/mL of plasma. Current US minipool HIV NAT screening protocols may not be sufficiently sensitive to detect all infectious window-period donations. JAMA. 2000;284:210-214

AIDS Serodiagnosis↗