Source localization for template implants with particular reference to stepping-source afterloaders.

Source localization from radiographs can be very difficult for template-guided implants if the needle images overlap. At UCSF several techniques to make this task easier have been developed. The techniques include selection of an optimum simulator gantry angle, use of different types of dummies, and differential dummy loading. In addition, several modifications have been made in our brachytherapy planning computer program to facilitate source entry. As a result of these improvements, source localization is now accomplished in much less time with improved accuracy.

Brachytherapy↗

Indications for and the significance of seminal vesicle irradiation during 3D conformal radiotherapy for localized prostate cancer.

PURPOSE: To evaluate the use of pretreatment prostate specific antigen, Gleason score, and clinical stage as predictors of the risk of seminal vesicle involvement in patients with clinically localized prostatic cancer, and to determine the impact of excluding the seminal vesicles on the dose received by surrounding normal tissues. METHODS AND MATERIALS: An empirically derived equation combining the preoperative prostate specific antigen and Gleason score was applied to 188 patients treated with radical prostatectomy, for whom pathologic evaluation of the seminal vesicles was available. High and low risk groups for seminal vesicle involvement were defined using this equation. The observed risks of seminal vesicle involvement was compared to the predicted risk using the preoperative prostate specific antigen, Gleason score or clinical stage alone or using the empirical equation. Dose-volume histograms for five patients treated using six-field conformal radiotherapy were compared including and excluding the seminal vesicles. RESULTS: Using the empirically derived equation, a low risk group of 109 patients was identified with a calculated risk of seminal vesicle involvement of < or = 13% and an observed incidence of 7.3%. Among the high risk group of 79 patients, which included all patients with a calculated risk > 13%, 37% had seminal vesicle involvement (p < 0.001 low vs. high risk). Twenty percent of the rectal volume received on average above 86% of the total dose for the five plans which included the seminal vesicles compared to 68% for the five plans excluding the seminal vesicles. The doses to 40% of the rectal volume were 64% and 37% if the seminal vesicles were included and excluded, respectively. The dose to the bladder and femoral heads was also decreased but to a lesser extent. CONCLUSION: The empirical formula predicts risk of seminal vesicle involvement with a higher degree of significance for a larger number of patients than either Gleason score, clinical stage, or prostate specific antigen alone. Based on an analysis of our first 100 patients treated with definitive conformal therapy alone, approximately 47% of those patients could have been treated excluding the seminal vesicles. Excluding the seminal vesicles may allow us to go to a higher total dose with less rectal toxicity.

Humans↗

Defining treatment margins for six field conformal irradiation of localized prostate cancer.

PURPOSE: To define the "ideal margins" to be used for the delivery of six-field conformal radiotherapy for localized prostate cancer. METHODS AND MATERIALS: For a typical patient, 3-D based 6-field conformal treatment plans were generated using uniform margins ranging from 0.5-2.5 cm (in 0.25 cm increments). In a step-wise fashion the minimum margins required to encompass the gross tumor volume within the 90% isodose shell were identified. Additional margins were then added to account for extracapsular penetration, setup and patients movement error as well as for organ movement. Assumptions about the relative tolerance of surrounding normal tissues were also incorporated into the final decisions regarding margins. RESULTS: For the various areas of interface, between the prostate and surrounding normal tissues "ideal margins" varied from 0.75-2.25 cm. CONCLUSION: The use of nonuniform "ideal margins" appears to insure adequate coverage of the tumor, while minimizing the volume of surrounding dose limiting normal tissues irradiated. This approach should in theory improve the tumor control and complication probabilities compared to using conventional treatment techniques and to using a 6-field conformal technique with uniform margins.

Humans↗

Applicability of standard irregular field calculations for high-energy photon beams.

Irregular-field calculations are usually based on a sector-summation technique. This technique typically involves separating the dose into primary and scatter components. While the conceptual basis for this procedure is valid at lower energies, it becomes suspect at higher energies. However, despite this limitation, a straightforward application of the technique yields good accuracy for 18 MV X-rays if certain limitations are observed. This work describes the calculational formalism used and the approximations made. Computed results are compared with measurements. The levels of uncertainty in both are discussed.

Humans↗

Bilateral arcs using "averaged beam's eye views": a simplified technique for delivering 3-D based conformal radiotherapy.

The purpose of this study is to describe a conformal radiotherapy technique for treating only the prostate with bilateral 120 degrees arcs using "averaged beams-eye-views" (A-BEV). For this study a CT scan from a patient with a large prostate but with a low risk for seminal vesicle involvement was chosen for comparing several different treatment techniques. Dose volume histograms (DVHs) of the prostate, femoral heads, bladder, and rectum were compared for plans using "standard" bilateral 120 degree unblocked arcs (8 x 8 and 9 x 9 cm), similar sized arcs with "generic" (small corner) blocks applied, arcs using hand drawn "semi-conformal" blocks added, and arcs using the A-BEV. The A-BEV was generated by averaging the shapes of fixed lateral and oblique BEVs from a six-field plan. These arc techniques were compared to four-field conformal (4-FC) and six-field conformal (6-FC) techniques. The addition of generic corner blocks to a 9 x 9 field resulted in a more favorable dose distribution than using open unblocked 9 x 9 arcs. The technique employing the A-BEV resulted in an improvement in the DVHs compared to other arc techniques and to 4-FC techniques. The dose volume histograms associated with using this technique approached those associated with using a 6-FC technique. Treating only the prostate with blocked arcs generated using an A-BEV results in an improved dose distribution compared to unblocked arcs and 4-FC techniques. This blocked arc technique also results in a DVH that is comparable to using a more complex 6-FC technique. Blocks that are drawn on manually reduce the dose to the surrounding normal tissues but are associated with a greater risk of underdosing the target volume. This problem is diminished when computer generated conformal blocks are used.

Humans↗

Optimization of the oblique angles in the treatment of prostate cancer during six-field conformal radiotherapy.

Historically, four perpendicular treatment fields or bilateral arcs have been used in the treatment of prostate cancer. As new techniques challenge the four-field box technique for their superiority of tumor coverage and adjacent critical structure sparing, oblique beam angles (in addition to right and left laterals) have been introduced as an alternative to anterior (AP) and posterior (PA) beams. Among the most popular of these alternative approaches is a six-field technique. Traditionally 45 degrees angles have been used with this technique. In this study, opposed coplanar oblique beams angled 20, 25, 30, 35, 40, and 45 degrees off the lateral beam position, were compared for their ability to minimize adjacent critical structure doses, while maintaining maximum clinical target volume (CTV) coverage. This analysis compared rectum, bladder, and femoral head dose volume histograms (DVH) for each of these varying oblique gantry angles. As the angle of the posterior oblique beams became more horizontal, it is more difficult to encompass the apex of the prostate in the 95% isodose value. On inferior CT slices near the apex of the prostate, the density of the pelvic bones in the path of the posterior oblique fields causes the beam to be slightly attenuated, thereby underdosing the CTV. The oblique angles most affected by this bone heterogeneity are beams angled from 20 to 30 degrees off the lateral beam position. As the angles approach the vertical direction, rectal and bladder doses increase, while femoral head doses decrease. Oblique gantry angles approaching the horizontal direction result in a decrease in rectal and bladder doses, while femoral head doses increase. Of the oblique angles studied, 35 degrees off the lateral position provides lower rectum and bladder doses than 30, 40, and 45 degrees; lower femoral head doses than 20, 25, and 30 degrees, and the maximum CTV coverage on all CT slices studied.

Adenocarcinoma↗

Immobilization improves the reproducibility of patient positioning during six-field conformal radiation therapy for prostate carcinoma.

PURPOSE: To determine the magnitude of patient positioning errors associated with six field conformal therapy for carcinoma of the prostate, and to assess the impact of alpha-cradle immobilization on these errors. METHODS AND MATERIALS: The records of 22 patients, treated at two of the treatment facilities within our department, using computed tomography-planned conformal six field therapy for carcinoma of the prostate, were reviewed. At one facility (UCD), patients were routinely treated with immobilization, while at the other (UCSF) no rigid immobilization was used. Portal films of patients treated at both facilities were subsequently reviewed, and the deviation of each portal from the simulation film was determined (simulation-to-treatment variability). In addition, for each patient, the average deviation of each portal film from the average portal film (treatment-to-treatment variability) was determined. RESULTS: The mean and median simulation-to-treatment variability was 0.4 cm for those patients treated with immobilization, versus 0.6 cm for those treated without immobilization. The 90th percentile of simulation-to-treatment variability was 0.7 cm for those patients treated with immobilization, versus 1.1 cm for those not immobilized. There was a significant reduction in the number of portals observed with errors of > or = 0.50 cm (132/201 vs. 37/87, 66% vs. 43%; p < 0.001), 0.75 cm (184/201 vs. 59/87, 92% vs. 68%; p < 0.001), and 1.0 cm (196/201 vs. 74/87, 98% vs. 85%; p < 0.001) for patients treated with immobilization. There was also a significant reduction in the number of patients with treatment-to-treatment variability > or = 0.5 cm (1/10 vs. 8/12; p = 0.01) for patients treated with immobilization. CONCLUSION: The use of immobilization devices significantly reduces errors in patient positioning, potentially permitting the use of smaller treatment volumes. Immobilization should be a component of conformal radiation therapy programs for prostate carcinoma.

Computer Simulation↗

The role of the urethrogram during simulation for localized prostate cancer.

Urethrograms on 89 consecutive patients with localized prostate cancer were evaluated retrospectively, and the inferior border of the treatment field based on this study was compared with the inferior border that would have been defined by using the lower border of the ischial tuberosities. An analysis of the relationship between the margin used and the dose at the inferior border of the prostate supported our policy of requiring a 2 cm margin for optimal coverage of the prostate. Inclusion of at least 1 cm of proximal penile urethra was essential to ensure this 2 cm margin. Based on this assumption, twenty-five percent of patients would have had an inadequate margin if the lower border of the ischial tuberosities had been used instead of the urethrogram to define the inferior border of the treatment field. Assuming that a margin of more than 3 cm inferiorly is excessive, 11% of patients would have had excessive urethral irradiation if the bottom of the ischial tuberosities had been used to define the inferior border. Combining these two extremes, more than one in three patients would have had an inappropriate inferior margin if the bottom of the ischial tuberosities had been used to define the inferior border of the treatment field. There was no apparent increase in morbidity as a result of the urethrograms or an increase in treatment related toxicity in association with using the treatment fields defined by urethrography. Computed tomography was complimentary in defining the apex of the prostate. These data support the routine use of the urethrograms during simulation for localized prostate cancer. The use of the lower border of the ischial tuberosities to define the inferior border of the treatment field is associated with an unacceptable risk of either underdosing the apical portion of the prostate or overdosing the urethra.

Aged↗

Normalization: what does it really mean?

Attempts have been made to standardize normalization techniques, but it remains a confusing issue. As of late there are five different possible normalization tools consisting of normalizing: 1. to the isocenter, 2. to a specific point other than the isocenter, 3. to a minimum target absorbed dose whose are of maximum target absorbed dose is a 2 cm2 area, 4. to an isodose value, 5. to the dmax of the beams. The International Commission on Radiation Units and Measurements has updated its report number 29 to further recommend normalization standards to include planning to a specification point that: 1. is easy to define in an unambiguous way, 2. is chosen in a region where the dose is rather homogeneous and representative of the dose distribution throughout the target volume, 3. defined where the dose can be accurately determined, 4. normalizes to the isocenter of the plan where the maximum absorbed dose is a 1.5 cm2 area, 5. limits the dose variation to 10%. With increasing complexity involving three-dimensional planning, mixed-beam therapy, and heterogeneity compensation, a full understanding of dose determination is necessary to accurately implement treatment plans.

Humans↗

An approach to abutting adjacent fields.

Problems arise in designing treatment techniques involving two pair of adjacent opposing fields where machine limitations require the patient to flip from supine to prone positions. Mantle and para-aortic treatments, in particular, can create challenging problems because of changes in patient position, different SSD's between adjacent fields, internal anatomical changes from supine to prone position, as well as field size and other treatment machine limitations. A simulator technique has been developed which takes cognizance of these limitations in specifying the gap between adjacent fields. It employs collinearity of the 50% decrement lines of adjacent-opposed field edges and the intersection of all four edges at an internal mid-plane match point. The technique maintains dose homogeneity and eliminates hot and cold triangles in the area of abutment. Simulation radiographs facilitate identification of collinearity with respect to a specific vertebra in the plane of abutment. In summary, this approach: Verifies abutment of coplanar fields by use of match film, improves isodose uniformity at mid-plane, evaluates dose distributions when abutment occurs at a point anterior or posterior to midline, prevents the possibility of spinal cord complications that might occur due to three field overlap.

Humans↗