Laplace reconstruction of experimental diagnostic x-ray spectra.

This paper displays the results of a blind study used to determine the capability of a Laplace transform pair model to accurately reconstruct diagnostic x-ray spectra from experimental attenuation data. Spectra reconstructed from attenuation measurements are compared to experimental spectra obtained on the same unit using an intrinsic germanium spectrometer system. The results show that when pure attenuation materials are used, good agreement is obtained between the experimental and computed spectra. If an alloy attenuator like 1100 aluminum is used, the proportion of contaminants must be included in the Laplace formulation for accurate reconstruction.

Alloys↗

Determination of diagnostic x-ray spectra with characteristic radiation using attenuation analysis.

An analytical method to compute x-ray spectra from attenuation data utilizing the Laplace transformation has been extended to include characteristic radiation. It is based on an a priori technique of determining the ratio of characteristic radiation exposure to the total radiation exposure in diagnostic spectra. The technique is shown to produce characteristic intensities in good agreement with experimentally determined values.

Humans↗

On the measurement of half-value layer in film-screen mammography.

Sources of variations in the measurement of half-value layer (HVL) in film-screen mammography are evaluated. Two principal sources are the energy responses of ionization chambers and the elemental compositions of the 1100 aluminum-alloy attenuation materials. Methods in measuring the thickness of attenuation materials are also an important potential source of error. These factors as well as the influence of geometry of measurement, position of measurement in the field, and precision of radiation output are examined. Recommendations for consistency in measurement are provided.

Biophysical Phenomena↗

The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology.

Factors affecting patient dose in all x-ray imaging modalities include beam energy, filtration, collimation, patient size, and image processing. In conventional radiography, the most important determinant of acceptable patient dose is use of the highest peak kilovoltage that results in diagnostic images. Digital radiography allows a much wider range of exposures than conventional radiography for producing diagnostic images. However, operators must be aware of the subtle differences in techniques used with digital systems to avoid unnecessary increases in patient dose. Low-dose mammography requires lower ranges of peak kilovoltage; different target materials, filters, and screen-film combinations; special attention to breast thickness, composition, and compression during the study; and different standards for grids, magnification, and optical density. Although peak kilovoltage and tube current are important for controlling patient dose in fluoroscopy, collimation, source-to-skin and patient-to-image intensifier distances, and control of beam-on time have perhaps greater importance. Computed tomography (CT) involves greater patient dose than conventional radiography, and, although the primary radiation dose is delivered to smaller volumes, dose calculations must account for dose received by adjacent tissue sections. Many variables are involved in fetal exposure and fetal dose effects, but a solid understanding of them can help in developing responsible patient management practices.

Abnormalities, Radiation-Induced↗