PubMed Health⌕ Search

Biomedical subjects

B R B Walters

Publications and source records attributed to B R B Walters.

4 recordsLinked to original sources

Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc.

This study examines the efficiencies of doses calculated using DOSXYZnrc for 18 MV (10 X 10 cm2 field size) and 6 MV (10 X 10 cm2 and 20 X 20 cm2 field sizes) photon beams simulated using BEAMnrc. Both phase-space sources and full BEAMnrc simulation sources are used in the DOSXYZnrc calculations. BEAMnrc simulation sources consist of a BEAMnrc accelerator simulation compiled as a shared library and run by the user code (DOSXYZnrc in this case) to generate source particles. Their main advantage is in eliminating the need to store intermediate phase-space files. In addition, the efficiency improvements due to photon splitting and particle recycling in the DOSXYZnrc simulation are examined. It is found that photon splitting increases dose calculation efficiency by a factor of up to 6.5, depending on beam energy, field size, voxel size, and the type of secondary collimation used in the BEAMnrc simulation (multileaf collimator vs photon jaws). The optimum efficiency with photon splitting is approximately 55% higher than that with particle recycling, indicating that, while most of the gain is due to time saved by reusing source particle data, there is significant gain due to the uniform distribution of interaction sites and faster DOSXYZnrc simulation time when photon splitting is employed. Use of optimized directional bremsstrahlung splitting in the BEAMnrc simulation sources increases the efficiency of photon beam simulations sufficiently that the peak efficiencies (i.e., with optimum setting of the photon splitting number) of DOSXYZnrc simulations using these sources are only 3-13% lower than those with phase-space file sources. This points towards eliminating the need for storing intermediate phase-space files.

Body Burden↗

Influence of ion chamber response on in-air profile measurements in megavoltage photon beams.

This article presents an investigation of the influence of the ion chamber response, including buildup caps, on the measurement of in-air off-axis ratio (OAR) profiles in megavoltage photon beams using Monte Carlo simulations with the EGSnrc system. Two new techniques for the calculation of OAR profiles are presented. Results of the Monte Carlo simulations are compared to measurements performed in 6, 10 and 25 MV photon beams produced by an Elekta Precise linac and shown to agree within the experimental and simulation uncertainties. Comparisons with calculated in-air kerma profiles demonstrate that using a plastic mini phantom gives more accurate air-kerma measurements than using high-Z material buildup caps and that the variation of chamber response with distance from the central axis must be taken into account.

Algorithms↗

Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting.

The introduction into the BEAMnrc code of a new variance reduction technique, called directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of interaction splitting for bremsstrahlung, annihilation, Compton scattering, pair production and photoabsorption, and Russian Roulette to achieve a much better efficiency of photon beam treatment head simulations compared to the splitting techniques already available in BEAMnrc (selective bremsstrahlung splitting, SBS, and uniform bremsstrahlung splitting, UBS). In a simulated 6 MV photon beam (10 x 10 cm2 field) photon fluence efficiency in the beam using DBS is over 8 times higher than with optimized SBS and over 20 times higher than with UBS, with a similar improvement in electron fluence efficiency in the beam. Total dose efficiency in a central-axis depth-dose curve improves by a factor of 6.4 over SBS at all depths in the phantom. The performance of DBS depends on the details of the accelerator being simulated. At higher energies, the relative improvement in efficiency due to DBS decreases somewhat, but is still a factor of 3.5 improvement over SBS for total dose efficiency using DBS in a simulated 18 MV photon beam. Increasing the field size of the simulated 6 MV beam to 40 x 40 cm2 (broad beam) causes the relative efficiency improvement of DBS to decrease by a factor of approximately 1.7 but is still up to 7 times more efficient than with SBS.

Algorithms↗

History by history statistical estimators in the BEAM code system.

A history by history method for estimating uncertainties has been implemented in the BEAMnrc and DOSXYznrc codes replacing the method of statistical batches. This method groups scored quantities (e.g., dose) by primary history. When phase-space sources are used, this method groups incident particles according to the primary histories that generated them. This necessitated adding markers (negative energy) to phase-space files to indicate the first particle generated by a new primary history. The new method greatly reduces the uncertainty in the uncertainty estimate. The new method eliminates one dimension (which kept the results for each batch) from all scoring arrays, resulting in memory requirement being decreased by a factor of 2. Correlations between particles in phase-space sources are taken into account. The only correlations with any significant impact on uncertainty are those introduced by particle recycling. Failure to account for these correlations can result in a significant underestimate of the uncertainty. The previous method of accounting for correlations due to recycling by placing all recycled particles in the same batch did work. Neither the new method nor the batch method take into account correlations between incident particles when a phase-space source is restarted so one must avoid restarts.

Biophysical Phenomena↗