PubMed Health⌕ Search

Biomedical subjects

B R Curtis

Publications and source records attributed to B R Curtis.

23 records · Page 2Linked to original sources

Invalidation of antiglobulin tests by a high thermal amplitude cryoglobulin.

A multiply transfused patient was referred for evaluation of a transfusion reaction. The direct and indirect antiglobulin tests (DAT, IAT) for alloantibody were negative. However, IgG-coated control cells failed to agglutinate in the negative reactions, casting doubt on their validity. At 4 degrees C, the patient's serum exhibited a large cryoprecipitate (2.9 mg/mL), made up predominantly of an IgG kappa paraprotein and having trace amounts of IgM and C3. Clear serum separated at 37 degrees C became cloudy within 10 minutes at room temperature (RT); within 4 hours, approximately 60 percent of the total precipitable cryoprotein had precipitated. Red cells (RBCs) incubated in fresh serum that had cooled to RT or RBCs obtained from RT or refrigerated samples contained cryoprecipitate that sedimented with the RBCs during washing with RT saline. On resuspension, enough IgG cryoglobulin redissolved to neutralize completely the commercial anti-IgG reagents. If the patient's samples were maintained at 37 degrees C, cryoprecipitate did not form, and RBCs washed four times at 37 degrees C gave valid DAT and IAT reactions. The removal of all cryoprecipitate from the patient's serum by centrifugation after overnight incubation at 4 degrees C also made possible valid antibody screening and compatibility tests.

Blood Grouping and Crossmatching↗

Inhibition of an anti-Pr1d cold agglutinin by citrate present in commercial red cell preservative solutions.

A patient with known cold autoimmune hemolyticanemia was admitted for surgery. Routine cold agglutinin evaluations, using commercial red cells (RBCs) in modified Alsever's preservative solution, revealed a cold agglutinin titer of 4 to 16. However, using RBCs washed four times with saline, a high-titer (greater than 2000 at 4 degrees C) cold autoagglutinin was demonstrated. The cold agglutinin was shown to be an IgM kappa paraprotein with anti-Pr1d specificity. The addition of Alsever's solution to washed RBCs inhibited the cold agglutinin. Each major component of Alsever's solution (neomycin, chloramphenicol, inosine, dextrose, and citrate) was tested individually; only citrate inhibited the patient's cold agglutinin. Various compounds structurally related to citrate were tested and found to cause various degrees of inhibition. The strongest inhibition correlated with the presence of either three carboxyl groups on molecules devoid of double-bonded carbon atoms or two carboxyl groups in cis configuration. A panel of 54 cold agglutinins, including 7 with anti-Pr specificity, was analyzed. None was significantly inhibited by Alsever's solution, although one with anti-Pr2 specificity was weakly inhibited. In summary, these studies describe an anti-Pr1d cold autoagglutinin that was inhibited by citrate in RBC preservative solutions. The failure to detect such a cold agglutinin can result from not washing RBCs free of citrate before testing.

Aged↗

Life-threatening, antiglobulin test-negative, acute autoimmune hemolytic anemia due to a non-complement-activating IgG1 kappa cold antibody with Pra specificity.

A 21-year-old man with fulminant cold autoantibody hemolytic anemia (CAHA) was hospitalized with hemoglobinemia, hemoglobinuria, hemoglobin concentration of 3.3 gm per dL, a negative direct antiglobulin test (DAT) with polyspecific and anti-C3d reagents, a negative Donath-Landsteiner test, and a cold agglutinin titer of 80. He failed to respond to corticosteroids, multiple plasma exchanges, and cyclophosphamide; he required 54 transfusions in 10 days to maintain a hemoglobin concentration of 6.0 to 10.0 g per dL. He improved dramatically after a splenectomy was performed. The wide-thermal-amplitude cold agglutinin proved to be an IgG1 kappa antibody with Pra specificity. The patient's serum exhibited normal complement activation. When the DAT was carried out at 0 to 4 degrees C, the result was strongly positive for IgG; the indirect antiglobulin test at 0 to 4 degrees C was positive with the patient's serum diluted 1 in 640. Within 6 months, he was in complete remission and receiving no therapy. As compared with eight patients with CAHA that was exclusively IgG-mediated, this patient is remarkable for his requirement for many transfusions and for DATs that were consistently negative for C3d.

Adult↗

A latex particle assay for platelet-associated IgG.

A modified, sensitive, solid-phase assay for platelet-associated IgG is reported. Direct comparisons were made between a 125I monoclonal radioimmunoassay (RIA) and the polyclonal antibody latex particle assay. In 209 simultaneous comparisons with the RIA, the sensitivity of the latex test was 91 percent, specificity was 100 percent, and overall efficiency was 97 percent. Commencing with platelet-rich plasma, the direct latex particle test for platelet-bound IgG requires 45 minutes; 90 minutes are required to crossmatch one patient with 12 donors. The advantages of the latex assay are absence of radioactivity, stability of reagents, economy, speed, specificity, and sensitivity.

Antibodies, Monoclonal↗

Clinical significance of increased density in the proximal femoral marrow detected by visual inspection on abdominopelvic postcontrast CT examination.

PURPOSE: The purpose of this study was to ascertain the clinical significance of increased density of the proximal femoral diaphyseal marrow when incidentally detected on postcontrast abdominopelvic CT examinations. METHOD: The proximal femoral marrow of 63 patients was classified as normal or abnormal based on visual inspection by three attending radiologists. Abnormal density was defined as attenuation greater than that of adjacent musculature. The attenuation of the marrow was also measured. All patient medical records were reviewed for pertinent laboratory and clinical data. RESULTS: Increased marrow density had a low sensitivity for anemia (28%) but a high specificity and positive predictive value (100%) for anemia. Three of these patients had unilaterally increased attenuation associated with local pathology. Visual inspection was adequate for identifying abnormalities in instances of underlying malignancy. CONCLUSION: Increased density of the proximal femoral diaphysis is a highly specific finding for a marrow replacement process. Anemia was the most common clinical diagnosis in our series of patients with abnormal marrow density. Although the sensitivity for increased bone marrow attenuation is low, the extremely high specificity and positive predictive value of this finding for marrow reconversion and/or replacement suggest that even if detected incidentally, it should not be disregarded and, in the absence of a preexisting causative diagnosis, warrants further evaluation. The specific pattern of marrow abnormality may be helpful in differentiating localized processes from other processes that may affect hematopoietic function in a more widespread or global distribution. In particular, visual inspection of marrow density was more specific for identifying asymmetric marrow density in localized processes than was a quantitative measure of difference between the two femurs (>20 HU).

Adult↗