PubMed Health⌕ Search

Biomedical subjects

B R Hopkinson

Publications and source records attributed to B R Hopkinson.

At least 37 records · Page 2Linked to original sources

Sigmoid ischemia and the inflammatory response following endovascular abdominal aortic aneurysm repair.

PURPOSE: To assess the relationship between sigmoid colonic perfusion, endotoxemia, and cytokine generation in patients undergoing elective open repair (OR) or endovascular repair (EVR) of infrarenal abdominal aortic aneurysms (AAA). METHODS: Ten patients (9 males; average age 67.6 +/- 2.5 years, mean aneurysm diameter 6.9 +/- 0.6 cm) undergoing OR were compared to 10 patients (all males; average age 70.3 +/- 2.6 years, mean aneurysm diameter 6.5 +/- 0.5 cm) whose repair was performed using the EVR technique. The partial pressure of the carbon dioxide gap (PCO2gap = tissue PCO2 - arterial PCO2) of the sigmoid colonic mucosa was measured using a silicone tonometer to evaluate bowel perfusion. Blood samples were collected into pyrogen-free heparinized tubes for quantification of plasma concentrations of endotoxin, tumor necrosis factor alpha (TNF-alpha), and interleukin 6 (IL-6) before, during, and after aortic repair. RESULTS: Patients in the OR group had a significantly greater increase in PCO2gap, suggesting a greater degree of bowel ischemia compared to the EVR group. This was associated with significantly greater postoperative concentrations of endotoxin, TNF-alpha, and IL-6 in the OR group. A significant correlation was found between PCO2gap, IL-6, and postoperative core temperature. CONCLUSIONS: The results suggest that the degree of bowel ischemia, endotoxemia, and cytokine generation following elective infrarenal AAA reconstruction may be reduced if the endovascular technique is used instead of conventional surgery.

Aged↗

Endovascular repair of perisplanchnic abdominal aortic aneurysm with visceral vessel transposition.

PURPOSE: To report a combined endoluminal and open surgical approach for a suprarenal abdominal aortic aneurysm (AAA) with coexistent splanchnic vessel stenoses. METHODS AND RESULTS: A 64-year-old man presented with an aneurysm of the proximal abdominal aorta and severe stenoses of the celiac axis and superior mesenteric artery (SMA). An initial 2-stage plan to stent the visceral vessel stenoses and exclude the aneurysm with a fenestrated stent-graft failed when the celiac lesion could not be crossed. The approach was changed to restore visceral perfusion with a bifurcated left iliosplenic and ilio-SMA bypass graft. Exclusion of the aneurysm was achieved with a custom-made suprarenal aortic tube stent-graft (Ivancev-Malmö) system. The patient is free of symptoms at 22 months, and there was no aneurysm visible on the 14-month CT scan. CONCLUSIONS: Hybrid techniques are an alternative treatment for complex perivisceral aortic aneurysms when total endovascular reconstruction is not possible.

Aortic Aneurysm, Abdominal↗

A prospective study to assess changes in proximal aortic neck dimensions after endovascular repair of abdominal aortic aneurysms.

OBJECTIVE: The purpose of this study was to detect any change in the proximal neck diameter after endovascular repair of abdominal aortic aneurysm. METHODS: The study was performed in a teaching hospital with an endovascular program on 112 patients who had undergone endovascular repair of abdominal aortic aneurysm. The interventions were pre-endovascular and postendovascular repair of abdominal aortic aneurysms with contrast-enhanced, spiral computerized tomography, and the main outcome measures were change in aortic proximal neck diameter, change in maximum aortic diameter, presence of endoleaks, and change in length from lowest renal artery to aortic bifurcation. RESULTS: The median anterior-posterior and transverse diameter decreased from 63.5 mm before surgery to 50.4 and 54.5 mm, respectively, after surgery in a period of 4 years. This trend in reduction in maximum diameter was not seen in the patients with endoleaks. There was no significant change in the proximal neck diameters when measured at 5-mm intervals after endovascular repair. There was also no significant change in the aortic length after endovascular repair. CONCLUSION: We have not demonstrated any evidence for proximal neck dilatation after endovascular repair of abdominal aortic aneurysm.

Aorta↗

Mortality rates following endovascular repair of abdominal aortic aneurysms.

PURPOSE: To present the perioperative and late mortality following endovascular repair (EVR) of abdominal aortic aneurysms (AAAs). METHODS: Data were collected prospectively on 221 patients undergoing AAA EVR over a 4-year period (median 5-month follow-up). Patients were classified preoperatively as high risk with at least 1 of these features: serum creatinine > 150 micromol/L, ischemic heart disease or poor left ventricular function, respiratory function < 50% of predicted normal, ruptured or symptomatic AAA, contraindication to or failed open repair, and age > 80 years. RESULTS: One hundred forty (63.3%) patients were classified as high risk, the most common criterion being cardiac disease (n = 96, 68.6%). There were 25 (11.3%) deaths in the 30-day perioperative period, 22 (15.7%) in the high-risk group compared to 3 (3.7%) in the acceptable-risk group (p = 0.02). The most common causes of perioperative death were multisystem organ failure and myocardial infarction. A further 21 (9.5%) late deaths occurred, 16 (11.4%) in the high-risk group and 5 (6.2%) in the acceptable-risk group (p > 0.1). CONCLUSIONS: The mortality of patients at acceptable risk undergoing EVR compares with the best published series for conventional open AAA repair. The perioperative and late mortality in the high-risk patients are substantially higher.

Aged↗

Endovascular AAA repair: prevention of side branch endoleaks with thrombogenic sponge.

PURPOSE: To report a technique that might decrease the incidence of lumbar artery endoleaks following endovascular repair (EVR) of abdominal aortic aneurysms (AAAs). METHODS: Ninety-three patients (86 males, median age 72 years, range 56 to 88) undergoing EVR with the aortomonoiliac technique were entered into a study to detect and then occlude patent side branches before completion of the endografting procedure. Prior to deploying the iliac occluder, an aneurysmogram was performed to detect patent aortic side branches. If these side branches were found, an absorbable gelatin sponge was inserted into the aneurysm sac via the occluder introducer sheath. The patients were followed with contrast-enhanced spiral computed tomography (CT) at 1 week and 3, 6, and 12 months to detect the presence of endoleaks. RESULTS: Forty-eight (52%) patients demonstrated patent side branches that were occluded by the insertion of gelatin sponges into the aneurysm sac. The remaining 45 patients without evidence of side branch flow were untreated. Ten (10.7%) patients died in the perioperative period, and 15 (16.1%) primary endoleaks (13 proximal, 2 distal) were detected. This left 68 (73.1%) patients for follow-up, 33 (48.5%) of whom had patent branch vessels treated with the thrombogenic sponge. The median follow-up was 4 months (range 1 to 17), during which time no side branch endoleak was detected on surveillance CT scans in any of the 68 patients, which included all patients treated with the thrombogenic sponge technique and those in whom no patent side branches had been identified. CONCLUSIONS: We have demonstrated a safe and reliable method of preventing lumbar artery endoleaks following endovascular AAA repair.

Aged↗

A study on the patency of the inferior mesenteric and lumbar arteries in the incidence of endoleak following endovascular repair of infra-renal aortic aneurysms.

OBJECTIVE: An endoleak is defined as the presence of contrast medium within the aneurysm sac on post-operative contrast-enhanced computed tomography scans (CT) in patients following endovascular repair (EVR) of abdominal aortic aneurysms (AAA). The aim of this study was to correlate the incidence of endoleaks with the presence of patent lumbar (LA) and inferior mesenteric arteries (IMA) as seen on pre-operative angiography. DESIGN, MATERIALS AND METHODS: Forty-seven patients were assessed pre-operatively by both CT and angiography by a blinded radiologist prior to EVR of AAA. The number and size of patent vessels was recorded and correlated with the incidence of LA or IMA endoleaks on follow-up CT. Patent lumbar vessels were scored: 1 = small, 2 = medium, 3 = large. RESULTS: Five patients were noted to have patent IMA on pre-operative angiography but none developed an endoleak. In this series, five patients had an endoleak due to a patent LA. The median score for patients with no endoleak was 1 (0-9) and for those with a lumbar endoleak 2 (0-5) (P = 0.26, Mann-Whitney U-test). The number of patent lumbar arteries was not predictive of a subsequent endoleak. Two out of nine (22 %) patients with large patent LA subsequently developed an endoleak. If a policy of pre-operative embolization on the basis of large patent LA had been adopted, seven patients would have had an unnecessary invasive procedure. CONCLUSION: Pre-operative angiography to look for patent LA and IMAs is not required in patients undergoing EVR or AAA.

Aortic Aneurysm, Abdominal↗

Early complications of femorofemoral crossover bypass grafts after aorta uni-iliac endovascular repair of abdominal aortic aneurysms.

OBJECTIVE: The following procedures are the 3 main methods of endovascular repair (EVR) of abdominal aortic aneurysms (AAA): aorto-aortic bypass grafting, bifurcated bypass grafting, and aorta uni-iliac grafts. The latter method has the potential disadvantage of requiring an extra anatomic graft (ie, a femorofemoral crossover bypass graft) to maintain contralateral pelvic and limb perfusion. The aim of this study was to assess the complications associated with the femorofemoral crossover bypass graft after aorta uni-iliac EVR of AAA. METHOD: A prospective review was conducted of the complications attributable to the femorofemoral crossover bypass graft in 136 patients who underwent EVR of AAA with an aorta uni-iliac device. RESULTS: During a median follow-up of 7 months (range, 0 to 36 months), 4 patients had superficial wound infections that required antibiotic treatment and 2 patients had bypass graft infections. Nine hematomas developed: 7 (5%) groin hematomas (6 in patients with Dacron bypass grafts), 1 scrotal hematoma, and 1 perigraft hematoma. One bypass graft thrombus developed. CONCLUSION: The femorofemoral crossover bypass graft is a safe and a durable component of EVR of AAA with an aorta uni-iliac device. The results are similar to those with bifurcated devices.

Aorta, Abdominal↗

Blood product requirements in patients undergoing elective endovascular abdominal aortic aneurysm repair.

OBJECTIVE: Endovascular repair (EVR) of abdominal aortic aneurysm (AAA) has many potential advantages, one of which may be reduced blood product requirements. The aim of this study was to compare the current blood product usage in our unit for three types of elective operation: EVR of AAA, open AAA repair and femorofemoral crossover grafts. DESIGN: Prospective data analysis with historical controls. MATERIALS: One-hundred and thirty-two patients undergoing elective EVR of AAA, 35 patients undergoing elective open repair of AAA and 37 patients having femorofemoral crossover grafts. METHODS: Data was collected on the blood product requirements of patients having EVR of AAA, with open AAA repair and femorofemoral crossover graft providing historical controls. RESULTS: There was no difference in the haematological parameters preoperatively between the three groups but postoperatively patients having EVR had a slightly lower haemoglobin than the open group (10.6 g/dl vs. 10.85 g/dl, p = 0.015). The number of patients who received blood transfusion in the EVR group was 82/132 (62%) and the open group 27/35 (77%), p = 0.4. CONCLUSION: Patients undergoing EVR of AAA require blood transfusion in the same numbers when compared to those undergoing open repair.

Aortic Aneurysm, Abdominal↗

A 10-year follow-up of patients presenting with ischaemic rest pain of the lower limbs.

OBJECTIVES: To determine the 10-year outcome of patients presenting with rest pain. METHODS: One hundred and three consecutive patients presenting with ischaemic rest pain in 1987 were followed up after 10 years. Hospital notes, death certificates and telephone interviews with patients were used to determine outcome. RESULTS: Follow-up data is available for 97 (94%) patients. Thirteen patients are alive (13.7%) after 10 years, 12 presented with rest pain alone and one had ulceration. Three of these had amputation. The commonest cause of death was myocardial infarction (n = 21, 25%). In those who had died, the median age of onset of symptoms was 72 years (49-93) for rest pain, 74 years (56-87) for ulceration and 71.5 years (45-85) for gangrene. Their survival after admission was a mean of 39 months with rest pain, 33 months with ulceration and 42 months with gangrene. The overall 5-year survival was 31% and the 10-year survival 13%. CONCLUSION: Patients presenting with ischaemic rest pain have a poor prognosis. The presence or absence of ulceration or gangrene does not influence the outcome. Most patients die from smoking-related diseases.

Adult↗

Common iliac artery aneurysms in patients with abdominal aortic aneurysms.

OBJECTIVES: To determine the incidence of common iliac artery (CIA) aneurysms in patients with abdominal aortic aneurysms (AAA) and to evaluate the relationship between AAA and CIA diameter. METHODS: Spiral CT angiography was used to measure the maximum diameters of the abdominal aorta and the common iliac arteries of 215 patients with AAA. RESULTS: The median CIA diameter was 1.7 cm--significantly greater than the published mean of 1.25 (2 S.D. = 0.85-1.65) cm of an age-matched, non-vascular population. Thirty-four patients (16%) had unilateral and 26 patients (12%) bilateral CIA aneurysms > or = 2.4 cm diameter. Eight-six vessels (20%) were affected. Right CIA diameters were wider than left CIA diameters (p < 0.0001, Wilcoxon matched-pairs signed rank test). The correlation between AAA size and CIA diameter was weak. CONCLUSIONS: The AAA population has abnormally dilated common iliac arteries. In this population, common iliac artery aneurysms should be defined as those greater than 2.4 cm diameter. 20% of CIAs in patients with AAA are aneurysmal according to this definition.

Aged↗

Thrombus distribution and changes in aneurysm size following endovascular aortic aneurysm repair.

OBJECTIVES: To determine (a) changes in aneurysm size following endovascular repair, (b) the significance of collateral lumbar artery blood flow and (c) the relationship between thrombus distribution within the aneurysm sac and the development of a "lumbar endoleak". MATERIALS AND METHODS: 72 patients treated with endovascular stent-grafts were followed up with spiral computed tomography for a median of 11 (range 3-27) months. The cross-sectional area of the aneurysm was measured at the point of maximum diameter pre- and post-operatively. The distribution and quantity of thrombus was recorded pre-operatively and this was related to changes in aneurysm size and the development of lumbar endoleaks post-operatively. RESULTS: An increase in aneurysm size occurred in 22 patients, of whom 10 had endoleaks. Fifteen aneurysms did not change in size, including four with endoleak, and 35 aneurysms decreased in size with no endoleaks. There was a significant difference between the endoleak and no endoleak groups (Chi-squared test = 17.1 with 2 degrees of freedom (d.f.), p < 0.001). Nine endoleaks were from patent lumbar arteries. No patients with thick circumferential or posteriorly placed thrombus developed an endoleak arising from lumbar vessels (0/23 cases) compared to those with minimal or anteriorly placed thrombus (9/49 cases) (Chi-squared test with Yate's correction = 3.17 with 1 d.f., p < 0.1). CONCLUSIONS: Aneurysms do not decrease in size in the presence of a lumbar endoleak, and some expand significantly. A number of aneurysms increase in size despite no evidence of an endoleak on computed tomography (CT). Patterns of thrombus distribution may be able to predict patients at risk from persistent endoleak via lumbar vessels.

Aortic Aneurysm, Abdominal↗

Spiral CT angiography versus aortography in the assessment of aortoiliac length in patients undergoing endovascular abdominal aortic aneurysm repair.

PURPOSE: To compare measurements of aortoiliac length obtained with spiral computed tomographic angiography (CTA) and aortography in patients undergoing endovascular aneurysm repair. METHODS: The distances from the lower-most renal artery to the aortic bifurcation and from the aortic bifurcation to the common iliac artery (CIA) bifurcation were measured using both CTA and aortography in 108 patients with abdominal aortic aneurysms. RESULTS: The level of agreement between CTA and aortography was high, with 69% of aortic and 76% of iliac measurements within 1 cm and > 90% within 2 cm of each other. Mean differences were -0.35 +/- 1.20 cm and 0.25 +/- 1.10 cm, respectively, for aortic and iliac lengths. Aortography overestimated renal artery to aortic bifurcation length in comparison to CTA (p = 0.003), particularly in patients with large aneurysms (> 6.5 cm) and lumen diameters > 4.5 cm (p < 0.0001). Measurements of CIA length were shorter by aortography than CTA (p = 0.02). CONCLUSIONS: There is a high level of agreement between CTA and aortography in the measurement of aortoiliac length, but aortography overestimates renal artery to aortic bifurcation length in patients with large-diameter aneurysms and wide aneurysm lumens. CTA is sufficiently accurate in the majority of cases to be used as the sole basis for the construction of endovascular grafts.

Aged↗

Renal complications following endovascular repair of abdominal aortic aneurysms.

PURPOSE: To investigate the renal complications associated with endovascular repair of abdominal aortic aneurysms (AAAs). METHODS: Data were prospectively collected on 164 AAA patients (154 males; median age 72 years; interquartile range 51 to 88) undergoing endovascular grafting. Any history of renal failure and diabetes mellitus was recorded. Serum urea and creatinine levels were measured preoperatively and at regular intervals postoperatively. Renal impairment was defined as serum creatinine > 130 micromol/L. RESULTS: There were no significant differences in pre- and 1-day postoperative serum urea and creatinine levels. Among 15 (9.1%) patients with preoperative renal failure, 7 (47%) died, 4 (27%) in the perioperative period. Of the 149 patients with normal renal function preoperatively, 4 (2.7%) developed renal failure as part of multisystem organ failure. Another 9 (6.2%) developed significant postoperative elevations (> 20%) in their creatinine levels compared to baseline; 4 of these patients died, 2 in the perioperative period. There was no significant difference in the median dose of intravascular contrast used for those patients that did and did not have a deterioration in their renal function (250 mL versus 300 mL). CONCLUSIONS: In this study, approximately 6% of patients with normal preoperative renal function who undergo endovascular AAA repair develop renal dysfunction. For patients with preoperative renal impairment, the perioperative mortality rate is high, 27%, following endovascular aortic aneurysm repair.

Acute Kidney Injury↗

Early results of endovascular aortic aneurysm surgery with aortouniiliac graft, contralateral iliac occlusion, and femorofemoral bypass.

PURPOSE: The aim of this study was to evaluate the feasibility of endovascular aortic aneurysm repair with use of an aortouniiliac graft secured with self-expanding (Gianturco) stents. METHODS: Thirty patients with a median age of 72 years (age range, 52 to 86 years) and aneurysm diameter of 6.0 cm (range, 4.0 to 9.0 cm) were treated with an aortouniiliac endovascular graft. Of these 30 procedures, 28 were carried out electively and two as emergencies for leaking aneurysm. Of the 30 patients, 21 (70%) were considered to be at high risk for open surgery. A modified Gianturco stent, Dacron graft, and Wallstent were used for these procedures. RESULTS: Endovascular repair was successfully carried out in 25 of 30 (83.3%) patients. All these patients were mobile and had resumed a normal diet within 48 hours of the procedure. The overall 30-day mortality rate was two in 30 (6.6%), but it was one in 28 (3.5%) for the elective cases; all deaths occurred in the group at high risk for surgery. Other complications encountered within 30 days of procedure included myocardial infarction in one patient, pneumonia in two patients, homonymous quadrantanopia in one patient, and colonic ischemia in one patient, giving an overall morbidity rate of four in 30 (13.3%). At a median follow-up of 4 months (range, 1 to 13 months), 27 of 30 (90%) patients remain alive and well. CONCLUSION: Endovascular aortouniiliac repair of abdominal aortic aneurysm with Gianturco stent is feasible in both elective and emergency situations. It appears to be minimally traumatic, and the majority of patients deemed to be at high risk for open surgery can safely undergo endovascular repair. However, data on more patients with longer follow-up is required to determine its role in the management of abdominal aortic aneurysm.

Aged↗

Bifurcated stent-graft for abdominal aortic aneurysm.

The purpose of this study was to examine bifurcated stent-graft implantation for abdominal aortic aneurysm. Fifty-seven patients were treated and followed with serial computed tomography scans for up to 3 years. Patients were allocated to three groups (first 20, second 20, last 17) according to when the repair was performed. Successful treatment is defined as exclusion of the aneurysm from the circulation, based on contrast computed tomography. Success rates in the three groups were 55%, 70% and 100%. Perigraft leak (endoleak) was present on initial assessment in 4/20, 2/20 and 1/17. Two of these aneurysms ruptured early in the postoperative period. Thereafter, leaks were sought and treated aggressively. Kinking and thrombosis occurred in six of the first 20 patients, but did not occur in any of the last 37 patients, in whom the graft limbs were routinely stent-supported throughout. Infrarenal implantation in very a short neck (< 10 mm), or a thrombus-lined neck was associated with proximal stent migration. In conclusion, changes in patient selection and technique have led to a steady rise in the short-term success rate of the stent-grafted implantation.

Aneurysm, Ruptured↗