PubMed Health⌕ Search

Biomedical subjects

B R Pullan

Publications and source records attributed to B R Pullan.

At least 19 recordsLinked to original sources

Low-level direct electrical current therapy for hepatic metastases. I. Preclinical studies on normal liver.

Low-level direct electrical current has shown promise as a potential therapeutic modality (direct current therapy; DCT) in the treatment of malignant disease, including metastases, but to date much experimental work has been empirical and has added little to our knowledge of the mechanisms involved. As a prerequisite to a clinical trial for metastases in the liver, we have employed an in vivo liver model to examine the quantitative and qualitative relationships between electrode polarity, charge and tissue necrosis. Two distinct regions of necrosis were induced, distinguishable histologically and by magnetic resonance imaging: (i) a cylindrical region of primary necrosis centred on the electrode, its volume directly proportional to the charge passed, but greater at the anode than cathode; and (ii) a wedge-shaped infarct, apex at the electrode and base extending to the liver edge. The extent of this infarct was again greater at the anode than the cathode, but showed a sigmoidal relationship with charge. Results indicate pH changes at the electrodes as likely mediators of tissue injury, but show also that significant distant ischaemic injury can occur as a consequence of primary damage. These findings should be considered when selecting tumours for possible direct current therapy and when determining the sites of electrode placement.

Animals↗

The effects of low-level direct current therapy on a preclinical mammary carcinoma: tumour regression and systemic biochemical sequelae.

Low-level direct electric current has been shown to be capable of destroying tumour tissue. Using an early-passage subcutaneous murine mammary carcinoma, the relationships between the volume of tumour destruction, charge and polarity have been examined. The results revealed a direct correlation between charge passed and absolute volume regression when the intratumoral electrode was made either an anode or a cathode. Tumour destruction for a given charge was significantly greater following anodic than cathodic treatment. A direct correlation was also observed between the percentage volume of prompt treatment-induced regression and the in situ end point of tumour growth delay. During the course of these experiments, a highly reproducible toxic effect was discovered, which has not been previously reported for this modality. An anodic charge greater than 10.6 coulombs or a cathodic charge greater than 21.6 coulombs resulted in 100% mortality at 24-72 h, while lower charges had no influence on mortality. Quantitative assays of a number of blood parameters showed that mortality was associated with serum electrolyte imbalances and appeared to be the result of the metabolic load of tumour breakdown products. These effects are similar to the tumour lysis or surgical crush syndromes and should not constitute a significant problem in clinical practice, where the tumour mass to total body mass ratio will normally be much smaller.

Animals↗

Ablation of neoplasia by direct current.

The application of low-voltage direct electrical current (DEC) has been studied in animals and humans for the ablation of anal condylomata, oesophageal cancer and Kaposi's sarcoma. Twenty milliamps of DEC passed through multiple 6 cm x 1 cm, flat-plate longitudinal electrodes into the squamous mucosa of the oesophagus of healthy dogs for periods ranging from 10 min to 2 h resulted in denudation and necrosis of the oesophageal mucosa at the site of application of the current. In humans, the application of DEC to two patients with benign anal condyloma acuminata, three patients with inoperable obstructing oesophageal cancer and one patient with disseminated Kaposi sarcoma resulted in striking necrosis of tumour tissue that was confirmed by macroscopic and microscopic studies. These initial findings imply promising therapeutic potential for the use of DEC as a simple, effective, safe, low-cost alternative for ablation of neoplasia.

Acquired Immunodeficiency Syndrome↗

Vertical gastric plication: an operation for gastro-oesophageal reflux.

An operation has been devised to prevent gastro-oesophageal reflux in which a vertical partition is made parallel to the proximal gastric lesser curvature. The technique, which can be simply, safely and rapidly performed, prevents reflux in the following ways: 1. Increasing the effective length of the 'intra-abdominal oesophagus'; 2. Increasing the crural sling and mucosal flap valve effect; 3. Sharpening the angle of entry into the gastric reservoir; 4. Creating a flutter valve and markedly reducing the gastric cross-sectional area along which reflux can occur. The stomach is neither opened nor divided. The efficacy of the operation was investigated in six dogs which had their lower oesophageal sphincter excised by circular myomectomy before vertical gastric plication. Pre- and postoperative manometric and oesophageal pH studies were performed. Vertical gastric plication prevented the oesophagitis produced by circular myomectomy alone. The operation has been performed in 26 patients over a 2-year period. Assessment has been by clinical methods, ambulatory 24 h pH studies and endoscopy. Twenty-one patients were classified in Visick grades I and II and ambulatory pH recordings showed a marked reduction in reflux in 13 of 14 patients. The operation is technically simple, quick and safe to perform, being accurately and scientifically reproducible.

Animals↗

Microvascular studies in non-specific inflammatory bowel disease.

The microvasculature was investigated in the normal bowel and in ulcerative colitis and Crohn's disease. Tissue samples from postoperative colectomy specimens in which the microvasculature had been perfused with barium sulphate suspension were examined. Microradiography was used to study intramural vascular pattern which was abnormal in both disease states. A recently described radiograph fluorescence system was used to estimate barium concentration and hence microvascular volume in tissue samples. Highly significant negative correlations were demonstrated between barium concentration and age in normal bowel (n = 44; r = -0.669; p less than 0.001) and in segmental Crohn's disease (n = 11; r = -0.698; p = 0.017). Barium concentration was significantly reduced (p less than 0.05) in segmental Crohn's disease (n = 11) but remained normal in diffuse Crohn's disease of the colon (n = 6) and ulcerative colitis (n = 7). It is postulated that ischaemia may be a factor in the pathogenesis of segmental Crohn's disease in older patients.

Adolescent↗

A method for the determination of microvascular volume in tissue samples.

An estimate of the volume of the microvascular bed in injected tissue specimens of human bowel has been made by measuring the concentration of injected contrast material using X-ray fluorescent analysis. The contrast medium used was barium sulphate and this completely fills the microvasculature in excised specimens. The concentration of barium in excised tissue samples has been determined by measuring the ratio of gamma-ray induced X-ray fluorescence in the barium to the 90 degree Compton scattered 140 keV gamma rays from a collimated 99Tcm source. Barium concentration was estimated in tissue samples from 45 specimens of normal bowel and 11 specimens of radiation damaged bowel. The radiation group showed a highly significant reduction (p less than 0.001) in barium concentration and therefore vascular volume. The mean percentage error for barium concentration measured on two separate occasions in 45 randomly selected tissue samples was 5%.

Barium Sulfate↗

Urethral lumen cross-sectional shape: its radiological determination and relationship to function.

This report shows that the urethral lumen cross-sectional shape is complex but slit-like and it is suggested that this shape is related to function. A radiological method for determining urethral shape during micturition has been developed and compared with histological studies. The lumen is markedly non-circular even during micturition. Simple theoretical analysis of preliminary shapes shows that current concepts of urethral flow are incomplete and urethral pressure profile measurements require re-evaluation. The function of accepted sphincter mechanisms requires a slit-like lumen. Lumen shape is a fundamental property of the urethra, the clinical importance of which has yet to be explored.

Adult↗

Effect of smoothing brain scans: a study using receiver operating characteristic curves.

A sample of computed tomography (CT) brain scans containing marginal lesions with different degrees of spatial smoothing was shown to two groups of observers. One group consisted of radiologists who had considerable experience in the interpretation of CT brain scans, whereas those in the other group had only limited experience. Neither group showed any significant change in ability to detect the marginal lesions when the pictures were smoothed. The groups were able to make diagnostic decisions even on pictures with high degrees of smoothing.

Brain↗

An analysis of the spatial distribution of attenuation values in computed tomographic scans of liver and spleen.

An autocorrelation analysis of the attenuation values in computed tomographic scans has been performed for a total of 35 normal and eighteen cirrhotic patients. The results confirm preliminary observations on a smaller sample which suggested that this technique may be used to separate normal and cirrhotic livers. The noise structure in a region within the spleen was also examined and found to change in the presence of cirrhosis.

Humans↗

Receiver operating characteristic curves in the evaluation of hard copies of computed tomography scans.

Receiver operating characteristic curves have been used to compare a variety of pictures derived from a number of hard copy devices used with EMI computed tomography scanners. The pictures examined were obtained from (a) a Shackman camera with bromide paper, (b) a Polaroid camera and Polaroid film, (c) a Shackman backed camera with radiographic film, and (d) an EMI multiformat imager. The results show no significant difference in detectability of an experimental object close to noise values using the various hard copies. It is concluded that the choice of a hard copy device might be based on considerations other than its physical performance.

Data Display↗

A technique for simultaneous dual energy scanning.

A method of deriving simultaneous dual energy scans on a conventional EMI CT5005 scanner is described. The only change that has to be made to the scanner involves the detector collimator where alternate slits are covered by a thin metal foil. The detector readings from the covered and uncovered slits are separated by software before picture processing to give two pictures from one scan--one at the usual X-ray energy and the other at a higher X-ray energy due to the beam hardening produced by the foil. A procedure is then outlined for converting these into pictures showing the effective electron density and the effective atomic number for the whole scan field.

Adolescent↗

Radiation dose in neuroradiological procedures.

Radiation dose is cumulative in the radiosensitive organs. In neuroradiology the organ of particular interest is the eye. There is an immutable physical relationship between spatial resolution, signal-to-noise ratio (i.e., density discrimination), and dose: Dose alpha (formula: see text). Optimal imaging conditions require a compromise between these three factors. The factors concerned in the effective utilisation of dose are discussed and the various compromises considered. Radiation dose measurements are given for a wide variety of neuroradiological procedures, including CT employing the EMI CT1010 and CT5005.

Cerebral Angiography↗

Tissue characterization by an analysis of the distribution of attenuation values in computed tomography scans: a preliminary report.

Attenuation values as measured by a computed tomography scanner are distributed in both magnitude and space. The distribution in magnitude can be described by the mean, standard deviation, and skewness of histograms of attenuation values. The distribution in space can be characterized by auto-correlation functions or histograms of gradients. Using these measures of scan structure, it has been shown that the spatial distribution of attenuation values can be influenced by tissue. Also, there are some indications that changes in tissue structure corresponding to disease can be detected.

Atrophy↗

Effect of secretogogues on mucosal blood flow in the antrum and corpus of the stomach.

Gastric mucosal blood flow in the rat was determined by the indicator fractionation technique of Sapirstein using Rb86Cl. Antral and corpus flow rates were determined in response to increasing doses of pentagastrin and histamine and the effect of vagotomy was determined. With progressive stimulation the antral:corpus flow ratio increased with both stimulants; however, vagotomy and noradrenaline reduced blood flow in both areas of mucosa. It is concluded that the antrum, as well as the corpus, actively responds to secretory stimulants by an increase in mucosal blood flow and support is provided for the theory that the antrum plays an active role in the control of parietal cell blood flow and secretion.

Animals↗