Low restenosis rate in lesions of the left anterior descending coronary artery with stenting following directional coronary atherectomy.

The present study evaluated acute and late results with stenting following directional coronary atherectomy (DCA) for the lesions in the left anterior descending coronary artery (LAD). Between April 1995 and January 1997, 200 LAD lesions with > or =3 mm reference vessel diameter were treated with coronary stents. The lesions were divided as to whether or not DCA was performed before stenting; 1) stenting alone (n = 163) and 2) debulking and stenting (n = 37). There were no significant differences in the incidences of complications except for non-Q-wave myocardial infarction that was more frequent in patients with debulking and stenting than in those with stenting alone (13.5% vs. 2.4%, P < 0.05). A greater acute lumen gain (2.85 +/- 0.66 vs. 2.25+/-0.60 mm, P < 0.01) and minimal lumen diameter (3.64+/-0.56 vs. 3.15+/-0.41 mm, P < 0.01) after stenting were observed in patients with debulking and stenting than in those with stenting alone. At follow-up patients with debulking and stenting continued to have a greater minimal lumen diameter (2.88+/-0.72 vs. 2.15+/-0.85 mm, P < 0.01) and had a lower restenosis rate (6.3% vs. 23.1%, P < 0.05) than those with stenting alone. Stenting following DCA appears to be advantageous in the LAD lesions with > or =3 mm reference vessel diameter.

Aged↗

Mechanical recanalization of total coronary occlusions with the use of a new guide wire.

The mechanical approach in the recanalization of total coronary occlusions consisted of the use of a new 0.014-inch standard coronary guide wire with jointless spring coil design that improves steering characteristics and tip stiffness. In addition, a 0.014-inch soft tip wire with hydrophilic coating and low-profile 1.5 mm over-the-wire balloons were used. The first wire was used selectively in 86 patients to treat 95 total occlusions, of which 51 (54%) were older than 3 months. Unfavorable angiographic characteristics were present in 79 (83%) of 95 lesions. Overall crossing success was 71% (67 of 95 lesions). Complications were one coronary perforation with cardiac tamponade necessitating emergency bypass surgery. In conclusion, the mechanical approach with the use of the standard coronary guide wire with jointless spring coil design provides a high success rate in the recanalization of unfavorable total occlusions.

Angioplasty, Balloon, Coronary↗

Coronary artery stenting in the elderly: short-term outcome and long-term angiographic and clinical follow-up.

OBJECTIVES: This study sought to compare the short- and long-term outcomes of elderly patients undergoing coronary artery stenting with those of younger patients and to determine the long-term clinical outcome and survival of elderly patients post stent implantation. BACKGROUND: Elderly patients undergoing coronary revascularization are considered a high-risk group. Few data exist that relate the results of stenting in treating coronary artery disease in the elderly population. METHODS: All elderly patients >75 years of age who underwent coronary artery stenting between March 1993 and July 1997 (n=137) at our center were compared to the patients <75 who underwent coronary artery stenting during the same time period (n=2,551). Long-term clinical follow-up and survival were determined for the elderly group. RESULTS: Elderly patients presented with lower ejection fractions (54% vs. 58%, p=0.0001), more unstable angina (47% vs. 28%, p=0.0001), and more multivessel disease (78% vs. 62%, p= 0.0001) than younger patients. These older patients had higher rates of procedure related complications including procedural myocardial infarction (MI) (2.9% vs. 1.7%, p=0.2), emergency CABG (3.7% vs. 1.4%, p=0.04), and death (2.2% vs. 0.12%, p=0.0001). Angiographic follow-up, obtained in both groups, demonstrated significantly higher restenosis rates in the elderly versus younger patients (47% vs. 28%, p=0.0007). Longer term clinical follow-up, which was obtained only in the elderly group, showed that at a mean follow-up period of 12 months post coronary stenting, elderly survival free from death, MI, revascularization and angina was 54% and that their overall survival was 91%. Subanalysis of the elderly patients who died showed much higher incidence of combined unstable angina (80%), prior MI (60%), lower ejection fraction (46%), multivessel disease (100%) and complex lesions (100%) than the overall group. CONCLUSIONS: Elderly patients who undergo coronary artery stenting have significantly higher rates of procedural complications and worse six month outcomes than younger patients, especially those who present with combined unstable angina, history of MI, EF < 50%, multivessel disease and complex lesions. Overall survival in the elderly population at 12 months postcoronary artery stenting was 91% and event-free survival was 54%.

Aged↗

Procedural and follow up results with a new balloon expandable stent in unselected lesions.

OBJECTIVE: To assess the clinical and angiographic results of the first clinical application of a new balloon expandable stent, the NIR stent, characterised by high longitudinal flexibility and low profile before expansion, and by high radial support and minimal recoil and shortening after expansion. DESIGN: Single centre survey of unselected lesions in consecutive patients. SETTING: Tertiary referral centre. PATIENTS AND LESIONS: 93 stents of various length (9, 16, and 32 mm) were implanted in 64 lesions in 41 patients. Twenty lesions (31%) were longer than 15 mm, and 17 lesions (27%) were located in vessels with a diameter smaller than 2.5 mm. Extreme tortuosity of the proximal vessel was present in 15 lesions (23%). All patients were treated with aspirin and ticlopidine. All lesions were evaluated before and after treatment by quantitative angiography, and in 47 lesions (75%) the stent expansion was also controlled by intracoronary ultrasound. Clinical follow up was available in all patients and angiographic follow up was performed in 53 lesions (84%), at a mean (SD) interval of 5.4 (1.7) months. RESULTS: Deployment of the stent failed in two lesions (3%). Minimum lumen diameter increased from 1.01 (0.54) mm to 2.94 (0.49) mm, and diameter stenosis decreased from 66(15)% to 7(11)%. There was one in-hospital non-Q wave myocardial infarction, one sudden death after 40 days, and 17 target lesion revascularisations (27%). Angiographic restenosis (> or = 50% diameter stenosis) was documented in 19 lesions (36% of all lesions with angiographic follow up), with an average residual diameter stenosis of 43(21)% and minimum lumen diameter of 1.63 (0.74) mm. Restenosis was more common in vessels with a reference diameter < 2.5 mm (45%) and for lesions longer than 15 mm (46%). CONCLUSIONS: The NIR stent could be used successfully in most lesions, achieving optimal angiographic results with very few in-hospital or subacute cardiac events. The angiographic restenosis rate and need for target lesion revascularisation remained high in this unfavourable lesion subset, especially in small vessels and long lesions.

Catheterization↗

Bifurcational stenting.

Treatment of bifurcation lesions is a complex issue, and there is no single panacea to the variety of lesions that form this cohort. The contribution of side-branch compromise to the adverse clinical events occurring after stent implantation need not be stressed and requires an aggressive approach including balloon dilatation before and after stent deployment. Various new techniques of kissing stent placement, such as the 'T', 'V', 'Y', and the culottes technique, have been proposed in recent years to treat different anatomical situations. The angle formed by the side-branches, the severity of involvement of the ostia and the vessel size are the main factors which influence selection of the strategy. Newer generations of stents, such as the bifurcate stents, tailor-made for bifurcation lesions, are evolving, and are expected to make a positive impact on the procedural outcomes and long-term results after bifurcation stenting. The development of new strategies and stent designs has greatly improved safety and immediate outcome of bifurcational stenting, but the procedural success still needs to be matched by an equal improvement in long-term patency.

Angioplasty, Balloon, Coronary↗

Persistent High Restenosis After Local Intrawall Delivery of Long-Acting Steroids Before Coronary Stent Implantation.

OBJECTIVE: This pilot study was performed to evaluate the feasibility and safety of intrawall delivery of long acting steroids before stent implantation, testing the efficacy of this treatment in reducing intimal hyperplasia in lesions at high risk for restenosis. METHODS: In 24 patients (40 lesions) local intrawall drug delivery of methylprednisolone acetate, using a new catheter device, was attempted before elective stent implantation. Treated lesions were compared to a matched control group. RESULTS: Lesions were classified AHA/ACC type C in 47% of cases, had a mean lesion length of 13.6 +/- 9.1 mm, and a mean vessel diameter of 2.85 +/- 0.44 mm. In 9 cases (25%) chronic total occlusions were treated. Methylprednisolone acetate (mean 60 +/- 23 mg) was delivered in 36 lesions (21 patients; delivery success 90%) in the remaining 4 lesions (10%) the delivery device did not cross the lesion. After drug delivery 46 stents were implanted (1.2 stent/lesion; stented segment length 30.1 +/- 18.8 mm) using high pressure for stent expansion (mean 16.4 +/- 3.1 atm). Intracoronary ultrasound guidance was used in 64% of cases. Procedural and in-hospital complications were: Two non Q wave myocardial infarctions (8%) and one (3%) subacute stent thrombosis. Angiographic follow-up was obtained in all 36 treated lesions (100%) and the angiographic restenosis rate (³ 50% diameter stenosis) was 39%. A reduction of the incidence of restenosis compared to the matched control group was not observed. CONCLUSIONS: Long acting steroids could be delivered locally with high success and low complication rates. The restenosis rate remained high in a subset of unfavorable lesions with high risk for restenosis.

Journal Article↗

Alcoholization of the interventricular septum (Sigwart procedure) for treatment of hypertrophic cardiomyopathy.

A patient with NYHA Class III dyspnea under medical treatment for hypertrophic cardiomyopathy underwent alcoholization of the first septal perforator. The procedure induced complete disappearance of the intraventricular gradient, with development of a Q-wave anterior myocardial infarction (peak CK rise = 1645 IU) and a complete right bundle branch block. After 5 months the patient maintains a marked improvement in functional capacity (NYHA Class I).

Cardiac Catheterization↗

Long-term angiographic and clinical outcome of patients undergoing multivessel coronary stenting.

BACKGROUND: Randomized clinical trials have shown that multivessel coronary angioplasty is feasible and provides similar long-term survival as bypass surgery in selected patients. However, the higher need for repeat intervention, in particular, coronary artery bypass graft surgery, remains a problem. The objective of this study was to test the hypothesis that multivessel stenting is safe and effective in reducing the need for repeat interventions, in particular, the need for bypass surgery. METHODS AND RESULTS: Between March 1993 and June 1995, 100 consecutive patients (243 lesions) had multivessel coronary stenting. High-pressure stent optimization was used in all patients. Procedural success was achieved in 97% of lesions; 2 patients (2%) required emergency bypass surgery. Angiographic follow-up was obtained in 89% of patients at 5.2+/-2.5 months. Angiographic restenosis occurred in 22% of the lesions, but 37% of patients had > or = 1 lesion with restenosis. Clinical follow-up was obtained in all patients at 21 +/- 10 months: target lesion revascularization was needed in 30 patients (30%), repeat angioplasty in 28 patients (28%) and coronary bypass surgery in 2 patients (2%); the overall survival rate was 96% (2% noncardiac death). CONCLUSIONS: Multivessel coronary stenting can be performed with high success rate and low need for emergency bypass surgery. Compared with historical results with multivessel percutaneous transluminal coronary angioplasty, patients who undergo multivessel stenting need less repeat interventions, in particular, less coronary bypass surgery and have similar long-term survival.

Aged↗

Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions.

BACKGROUND: Intravascular ultrasound (IVUS) provides more precise information than angiography about vascular dimensions. This information is used by some centers to optimize intracoronary stent implantation. There are no direct comparisons of the effects on restenosis of optimal IVUS-guided versus angiography-directed high-pressure stenting. METHODS AND RESULTS: Lesions of patients who had a 6-month angiographic follow-up study were eligible for matching. From 445 consecutive lesions treated by Palmaz-Schatz (P-S) stenting guided by IVUS (IVUS group) in Milan, 173 lesions were individually matched with 173 of 476 consecutive lesions treated by P-S stenting directed by angiography (Angio group) in Hamburg. Lesions were selected by a computerized program according to baseline clinical, angiographic, and procedural variables. Immediate and 6-month angiographic results were retrospectively compared, distinguishing an "early phase" from a "late phase." This distinction was based on the more aggressive dilation strategy with larger balloons and more demanding IVUS criteria for optimal stent expansion used in Milan in the early phase. In both phases, a larger minimum lumen diameter (MLD) immediately after stenting and after 6 months was achieved in the IVUS group than in the Angio group. In the early phase, the dichotomous restenosis rate was lower in the IVUS group than in the Angio group (9.2% versus 22.3%; P=.04). In the late phase, there was no difference in restenosis between the groups (22.7% versus 23.7%; P=1.0). CONCLUSIONS: In matched lesions treated with high-pressure stenting, IVUS guidance achieved a larger MLD than angiographic guidance. However, in the IVUS group, the restenosis rate was lower only in the early phase, when balloons larger than currently used were selected to maximize the stent lumen area.

Adult↗

Coronary stenting after rotational atherectomy in calcified and complex lesions. Angiographic and clinical follow-up results.

BACKGROUND: Treatment of calcified (in contrast to simple) lesions with PTCA has been associated with a lower success rate and more procedural complications. Rotablation can improve acute results, but the high restenosis rate remains a problem. The purpose of this study was to evaluate the clinical and angiographic outcome of patients with complex and calcified lesions treated with a combination of rotablation and stenting. METHODS AND RESULTS: Seventy-five consecutive patients with 106 lesions had rotablation prior to coronary stenting. Intravascular ultrasound-guided stenting was used without subsequent anticoagulation in 93% of patients. Procedural success was achieved in 93.4% of lesions. Acute stent thrombosis occurred in two lesions (1.9%), and subacute stent thrombosis in one lesion (0.9%). Angiographic follow-up was performed in 82.5% of lesions at 4.6 +/- 1.9 months with an angiographic restenosis rate of 22.5%. Clinical follow-up was performed in all patients at 6.4 +/- 3 months; target lesion revascularization was needed in 18% of lesions; Q-wave myocardial infarction occurred in 1.3%, coronary bypass surgery in 4.0%, and death in 1.3%. CONCLUSIONS: Optimal coronary stenting after rotablation in calcified and complex lesions can be performed with a high success rate, an acceptable rate of procedural complications, and a low rate of stent thrombosis. This approach was associated with a low incidence of angiographic restenosis compared with results usually obtained with other interventional strategies in calcified and complex lesion subsets.

Aged↗

Troponin T, creatine kinase MB mass, and creatine kinase MB isoform ratio in the detection of myocardial damage during non-surgical coronary revascularization.

The presence of myocardial injury during non-surgical coronary revascularization has been evaluated by means of highly specific and sensitive biochemical markers. Troponin T, creatine kinase-MB isoenzyme mass concentration, and creatine kinase MB2/MB1 isoform ratio have been determined in 80 patients who underwent coronary revascularization with percutaneous transluminal coronary angioplasty (PTCA). Forty-five patients underwent balloon angioplasty, 15 rotational atherectomy, 10 directional atherectomy, and 10 elective coronary stenting. Serum concentration of the evaluated markers did not increase significantly after 57 uncomplicated revascularization procedures, including 15 rotablation procedures, nor after 8 PTCAs complicated by localized coronary type B and C dissections. Significant elevation of all markers above the upper limits of the reference interval (P < 0.05) was detected after occlusion of small side branches (< 0.5 mm diameter) in 5 patients. Creatine kinase MB2/MB1 isoform ratio was the earliest marker to increase. After recanalization of occluded vessels in 8/10 patients with 6-60 days old myocardial infarction only troponin T concentrations increased from a baseline of 0.28 microgram/l to a median peak of 0.80 microgram/l. This increase was statistically not significant (P = 0.12). In conclusion, myocardial damage was not detected following uncomplicated non-surgical revascularization obtained with different techniques. Markers of myocardial injury provide high sensitivity after small side branch occlusion.

Aged↗

New approach to quantitative angiographic assessment after stent implantation.

The new generation quantitative angiographic systems apply the interpolated technique to calculate the reference diameter at the site of the stenosis by integrating measurements of the segments proximal and distal to the stenosis. After stent implantation these measurements can be misleading as the treated segment, which is frequently larger than the adjacent not stented segments, is included in the measurements. The consequence is an overestimation of the reference diameter and the residual diameter stenosis. The present study was performed to compare this conventional technique of measurement with a new method which excludes the stented segment for the calculation of the reference diameter. Fifty-two lesions treated with poorly radiopaque stents (56% Palmaz-Schatz, 28% NIR, 10% Gianturco-Roubin, 6% Wallstent) expanded at high pressure (> = or 16 atm) were analyzed according to the conventional and stent excluded method. After stent implantation the reference diameter was 3.39 +/- 0.48 mm with conventional measurements and 3.02 +/- 0.45 mm with the stent excluded method (P < 0.05). The corresponding % diameter stenosis was 13 +/- 9 for the conventional technique and 1 +/- 13 for the stent excluded analysis (P < 0.05). The new approach to quantitative coronary analysis after stenting provides higher accuracy in reference diameter calculations and allows a more appropriate matching of stented segments with adjacent normal segments.

Angioplasty, Balloon, Coronary↗

New stent delivery balloon: a technical note.

This study reports the first clinical application of a new noncompliant balloon composed of a middle polyurethane layer sandwiched between an inner layer of polyethylene terephtalate and an outer membrane that provides for consistent even expansion. With this balloon design, the very low compliance and high pressure resistance of polyethylene terephthalate are associated with the high elasticity of polyurethane, preventing balloon damage from stent crimping and expansion and allowing a firm embedding of the stent struts. Palmaz-Schatz stent implantation was successful in 33/35 stents (94%), and the two stents that could not be advanced up to the lesion were successfully withdrawn. High pressure expansion of the stent was obtained during deployment with no balloon ruptures at inflation pressures equal or lower than 16 atmospheres (atm). Accurate positioning of the stent was facilitated by the two markers at the balloon ends and by the optimal visualization after contrast injection, even with 6 Fr guiding catheters. This new delivery system maintains the advantages of hand-crimped stents on noncompliant balloons, reducing the risk of stent loss.

Angioplasty, Balloon↗

Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: frequency, predictors and clinical outcome.

OBJECTIVES: This study was performed to determine predictors of subacute stent thrombosis (SST) in the era of intravascular ultrasound (IVUS)-guided coronary stenting without anticoagulation. BACKGROUND: The incidence of stent thrombosis has declined with the application of high pressure stent deployment with only antiplatelet therapy. However, no data are available on predictors of stent thrombosis in this era. METHODS: Between March 30, 1993 and July 31, 1995, 1,042 consecutive patients underwent coronary stenting without anticoagulation. For this analysis, we excluded patients who underwent coronary artery bypass surgery, died or had acute stent thrombosis within the 1st 24 h after stenting (41 patients). A total of 1,001 patients (1,334 lesions) were included; 982 patients (1,315 lesions) without SST and 19 patients (19 lesions) with SST. RESULTS: The rate of SST was 1.9% (per patient). There was no difference between the SST and No SST groups in rescue stenting (12% vs. 13.5%, p = 1.0) or mean +/- SD reference diameter (3.11 +/- 0.58 vs. 3.19 +/- 0.53 mm, p = 0.54). A preexisting thrombus was present in 12% of the SST group and in 4.5% of the No SST group (p = 0.19). Predictors of SST by univariate analysis were low ejection fraction (p = 0.004), more stents per lesion (p = 0.049), use of combination of different stents (p = 0.012), smaller balloon size (p = 0.012) and suboptimal result in terms of smaller lumen dimensions by angiography (p = 0.016) and IVUS (p = 0.004), residual dissections (p = 0.027) and slow flow (p = 0.0001). In stepwise logistic regression analysis, ejection fraction (p = 0.019), use of a combination of different stents (p = 0.013) and postprocedure dissections (p = 0.014) and slow flow (p = 0.0001) were predictive of SST. CONCLUSIONS: In the present era of stent implantation, factors that may predispose to SST are low ejection fraction, intraprocedural complications leading to utilization of more stents, particularly with different stent designs, and suboptimal final result in terms of smaller lumen dimensions and persistent slow flow and dissections.

Anticoagulants↗

Long-term clinical follow-up after successful repeat percutaneous intervention for stent restenosis.

OBJECTIVES: This study evaluated the long-term clinical outcome of successful repeat percutaneous intervention after in-stent restenosis. BACKGROUND: Recurrence of symptoms and angiographic restenosis after stent implantation are observed in 15% to 35% of cases. Repeat percutaneous treatment for in-stent restenosis has been shown to be safe, with high immediate success, but little is known about the long-term clinical outcome. METHODS: Clinical follow-up (minimum 9 months) was obtained in a consecutive series of 124 patients (127 vessels) presenting with stent restenosis who were successfully treated with repeat percutaneous intervention. RESULTS: Clinical follow-up was obtained in all 124 patients at a mean [+/-SD] of 27.4 +/- 14.7 months (range 9 to 66); a stress test was available in 88 patients (71%). Recurrence of clinical events occurred in 25 patients (20%) and included death from any cause in 2 patients (2%), target vessel revascularization in 14 (11%), myocardial infarction in 1 (1%) and positive stress test results or recurrence of symptoms (Canadian Cardiovascular Society class I to IV) treated medically in 8 (6%). Cumulative event-free survival at 12 and 24 months was 86.2% and 80.7%, respectively. Significant predictive factors of recurrence of clinical events were repeat intervention in saphenous vein grafts, multivessel disease, low ejection fraction and a < or = 3-month interval between stent implantation and repeat intervention. CONCLUSIONS: In-stent balloon angioplasty for stent restenosis in native vessels seems to be an effective method in terms of a low long-term clinical event rate.

Aged↗

Coronary stenting in 1000 consecutive patients. Long-term clinical and angiographic results.

Coronary stent implantation has become an accepted treatment for selected patients but the long-term outcome after stent implantation has not been investigated in a large unselected population. This study reports clinical and angiographic results after coronary stent implantation in a consecutive group of 1000 patients treated between November 1989 and June 1994. A total of 2012 stents were implanted in 1216 lesions. The anticoagulation regimen after successful stenting was abolished in the last 499 patients, treated with aspirin and ticlopidina. Complex lesions (type B2, type C lesions and chronic total occlusions) were less frequent in the group with anticoagulation (67%, 355/529 lesions) than in the group without anticoagulation (76%, 485/641; p < 0.01). Vessel size was also significantly smaller in the group with no anticoagulation (3.21 +/- 0.50 mm vs 2.89 +/- 0.70 mm; p < 0.001). Procedural success was achieved in 96% of cases. Major complications occurred in 49 pts, including death (1%), emergency bypass surgery (2.7%), and myocardial infarction (2.1%). Subacute stent thrombosis, observed in 2.6% of the patients treated with anticoagulation, decreased to 1% in the last 499 patients receiving only antiplatelet drugs after high pressure stent expansion controlled with intravascular ultrasound (p < 0.05). Angiographic follow-up was obtained at a mean interval of 6.6 +/- 3.0 months in 718 patients (75% of the eligible candidates). The global restenosis rate (greater than 50% diameter stenosis) was 22%, with no statistically significant difference in patients with and without anticoagulation after stenting. Clinical follow-up was available in 890 patients at a mean interval of 14 +/- 17 months. Late cardiac events occurred in 251 patients and included: 159 repeat coronary angioplasties for restenosis (20%), 114 coronary angioplasties for de novo lesions (10%), 33 elective by-pass surgery operations (3.7%) and 42 late deaths (4.7%). At the most recent follow-up there were 719 pts (81%) free of anginal symptoms, including patients having repeat angioplasty for restenosis or disease progression. Coronary stenting has a low incidence of procedural complications and high-pressure ultrasound guided implantation has drastically reduced the risk of subacute thrombosis. Repeat procedures due to restenosis remain the most important limitation of the technique and do not seem to be affected by evolving technique and operator experience.

Angioplasty, Balloon, Coronary↗

Subintimal stent implantation for the treatment of a chronic coronary occlusion.

Subintimal passages of the guide wire during mechanical recanalization of chronic coronary occlusions are frequent and may result in the inability to reestablish anterograde flow in the distal coronary lumen. By using coronary stents, a conduct through the subintimal pathway can be obtained, allowing long-term restoration of the anterograde blood flow. We report on a case of a long, subintimal vessel reconstruction of a five-year-old coronary occlusion. Under intravascular ultrasound guidance, multiple coronary stents were implanted and good procedural and long-term clinical and angiographic results were achieved.

Aged↗