PubMed Health⌕ Search

Biomedical subjects

B S Garra

Publications and source records attributed to B S Garra.

At least 19 recordsLinked to original sources

Biomechanical response to acupuncture needling in humans.

During acupuncture treatments, acupuncture needles are manipulated to elicit the characteristic "de qi" reaction widely viewed as essential to acupuncture's therapeutic effect. De qi has a biomechanical component, "needle grasp," which we have quantified by measuring the force necessary to pull an acupuncture needle out of the skin (pullout force) in 60 human subjects. We hypothesized that pullout force is greater with both bidirectional needle rotation (BI) and unidirectional rotation (UNI) than no rotation (NO). Acupuncture needles were inserted, manipulated, and pulled out by using a computer-controlled acupuncture needling instrument at eight acupuncture points and eight control points. We found 167 and 52% increases in mean pullout force with UNI and BI, respectively, compared with NO (repeated-measures ANOVA, P < 0.001). Pullout force was on average 18% greater at acupuncture points than at control points (P < 0.001). Needle grasp is therefore a measurable biomechanical phenomenon associated with acupuncture needle manipulation.

Acupuncture↗

Viewing DICOM-compliant CT images on a desktop personal computer: use of an inexpensive DICOM receive agent and freeware image display applications.

OBJECTIVE: Our objective was to determine the ease of installation and use of relatively inexpensive and free software applications that allow Macintosh users to receive and view CT images from a Digital Imaging and COmmunication in Medicine-compliant imaging network. CONCLUSION: Simple-to-use Macintosh-based options to transfer and view images are readily available and easily installed by users with minimal computer expertise.

Humans↗

Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements.

In a study involving 10 different sites, independent results of measurements of ultrasonic properties on equivalent tissue-mimicking samples are reported and compared. The properties measured were propagation speed, attenuation coefficients, and backscatter coefficients. Reasonably good agreement exists for attenuation coefficients, but less satisfactory results were found for propagation speeds. As anticipated, agreement was not impressive in the case of backscatter coefficients. Results for four sites agreed rather well in both absolute values and frequency dependence, and results from other sites were lower by as much as an order of magnitude. The study is valuable for laboratories doing quantitative studies.

1-Propanol↗

Assessment of bone density using ultrasonic backscatter.

The goal of this project was to investigate the utility of ultrasonic backscatter for the assessment of bone status. Ultrasound offers a low-cost, portable, nonionizing alternative or complement to common X-ray- or radioisotope (gamma ray)-based methods of bone densitometry. Ultrasonic backscatter may provide useful information not revealed by ultrasonic attenuation and sound-speed densitometers. Backscatter is sensitive to microstructural variations in acoustic impedance and should therefore provide information regarding architecture (which is related to fracture risk), as well as density. Ultrasonic backscatter at 2.25 MHz and CT bone densitometric data have been acquired from 10 healthy human volunteers. The degree of correlation between CT and ultrasonic backscatter is high (r = 0.87, p < 0.001). The envelope signal-to-noise ratio was 1.81 +/- 0.08 (mean +/- standard deviation). This suggests that the number of scatterers per resolution cell is large, the radiofrequency signal approximately obeys circular Gaussian statistics, and the envelope obeys Rayleigh statistics. These results indicate promise for ultrasonic backscatter as a substitute for or an adjunct to other ultrasonic measurements (attenuation and sound speed) and X-ray measurements for the assessment of bone status.

Adult↗

Elastic moduli of breast and prostate tissues under compression.

To evaluate the dynamic range of tissue imaged by elastography, the mechanical behavior of breast and prostate tissue samples subject to compression loading has been investigated. A model for the loading was validated and used to guide the experimental design for data collection. The model allowed the use of small samples that could be considered homogeneous; this assumption was confirmed by histological analysis. The samples were tested at three strain rates to evaluate the viscoelastic nature of the material and determine the validity of modeling the tissue as an elastic material for the strain rates of interest. For loading frequencies above 1 Hz, the storage modulus accounted for over 93 percent of the complex modulus. The data show that breast fat tissue has a constant modulus over the strain range tested while the other tissues have a modulus that is dependent on the strain level. The fibrous tissue samples from the breast were found to be 1 to 2 orders of magnitude stiffer than fat tissue. Normal glandular breast tissue was found to have an elastic modulus similar to that of fat at low strain levels, but the modulus of the glandular tissue increased by an order of magnitude above fat at high strain levels. Carcinomas from the breast were stiffer than the other tissues at the higher strain level; intraductal in situ carcinomas were like fat at the low strain level and much stiffer than glandular tissue at the high strain level. Infiltrating ductal carcinomas were much stiffer than any of the other breast tissues. Normal prostate tissue has a modulus that is lower than the modulus of the prostate cancers tested. Tissue from prostate with benign prostatic hyperplasia (BPH) had modulus values significantly lower than normal tissue. There was a constant but not significant difference in the modulus of tissues taken from the anterior and posterior portions of the gland.

Adult↗

Elastography of breast lesions: initial clinical results.

PURPOSE: To determine the appearance of various breast lesions on elastograms and to explore the potential of elastography in the diagnosis of breast lesions. MATERIALS AND METHODS: A total of 46 breast lesions were examined with elastography. Patients underwent biopsy or aspiration of all lesions, revealing 15 fibroadenomas, 12 carcinomas, six fibrocystic nodules, and 13 other lesions. The elastogram was generated from radio-frequency data collected with use of a 5-MHz linear-array transducer. The elastogram and corresponding sonogram were evaluated by a single observer for lesion visualization, relative brightness, and margin definition and regularity. The sizes of the lesions at each imaging examination and at biopsy were recorded and compared. RESULTS: Softer tissues such as fat appear as bright areas on elastograms. Firm tissues, including parenchyma, cancers, and other masses, appear darker. The cancers were statistically significantly darker than fibroadenomas (P < .005) and substantially larger on the elastogram than on the sonogram. Seventy-three percent of fibroadenomas and 56% of solid benign lesions could be distinguished from cancers by using lesion brightness and size difference. Some cancers that appeared as areas of shadowing on sonograms appeared as discrete masses on elastograms. CONCLUSION: Elastography has the potential to be useful in the evaluation of areas of shadowing on the sonogram. It also may be helpful in the distinction of benign from malignant masses.

Breast Neoplasms↗

Helical CT of renal masses: the value of delayed scans.

OBJECTIVE: Routine scanning techniques used for helical CT of the abdomen result in dense cortical opacification of the kidney, whereas the medulla and collecting system are not well opacified, which potentially compromises detection of renal masses. The purpose of this retrospective study was to determine if additional delayed views (taken approximately 2-4 min after the start of injection of contrast material) are necessary for the detection and characterization of renal masses. MATERIALS AND METHODS: Early (60-70 sec after the start of the injection of contrast material) and delayed scans of 40 patients with suspected renal masses were blindly evaluated by two observers. The patients harbored a total of 187 renal masses (including 62 solid masses). Each region of the kidney (upper, middle, and lower pole) was scored for the presence of a mass. Scoring was done as a binary decision and also as a five-point confidence score for receiver operating characteristic analysis. RESULTS: We found 97 regions that contained renal masses and 114 regions that did not. Receiver operating characteristic analysis revealed the observers to have significantly greater confidence in detection of renal masses on the delayed scans. The binary data showed the two observers to have a sensitivity of 97% for delayed scans versus 77% (p = .0002) and 89% (p = .027), respectively, for the early scans. For the first observer, early and delayed scans were of equal specificity, but for the second observer, the delayed scans yielded greater specificity (94% versus 85%, p = .024). On the early scans, both observers were significantly more likely to miss a neoplastic lesion than a nonneoplastic lesion. The less experienced of the two observers also tended to have greater difficulty in characterizing the lesions on the early scans. CONCLUSION: Because of the significant risk of missing a renal mass, especially a neoplasm, on early cortical-phase scans, additional delayed scans appear justified when a renal mass is suspected on the basis of other imaging tests or clinical history.

Adult↗

Measurements of ultrasonic backscatter coefficients in human liver and kidney in vivo.

Ultrasonic backscatter coefficients, in the range of 2.0-4.0 MHz, were measured in normal human livers and kidneys in vivo. In liver, data were acquired and analyzed from 15 normal volunteers and 19 patients with hepatitis. No significant difference between normal and chronic hepatitis was found. The power-law fit to the backscatter coefficient in normal liver as a function of frequency was eta(f) = 4.5 x 10(-5) f1.6 cm-1 Str-1. This is comparable to that measured by other investigators in in vitro preparations of human and animal liver and to that measured by two other teams of investigators in in vivo human liver. In kidney, data were acquired from 11 normal volunteers. The power-law fit to the backscatter coefficient in normal kidney was eta (f) = 2.3 x 10(-5) f2.1 cm-1 Str-1. This is in the range of that measured by other investigators in in vitro preparations of human and animal kidney. In order to assess the system dependence of in vivo abdominal organ backscatter coefficients, measurements were performed using two different ultrasonic data-acquisition systems. The two systems exhibited close agreement.

Chronic Disease↗

Biliary tract: three-dimensional helical CT without cholangiographic contrast material.

Bile duct anatomy depicted with a three-dimensional (3D) model developed with helical computed tomography (CT) data was compared with cholangiographic depiction. The ductal system was completely displayed from all angles in four of six patients, as well as the stricture and length of bile duct between strictures and the bifurcation in five of six cases. 3D rendering can depict preoperative ductal anatomy.

Adult↗

Quantitative ultrasonic detection of parenchymal structural change in diffuse renal disease.

OBJECTIVE: The authors determined whether quantitative ultrasound could be useful in the evaluation of diffuse renal disease. METHODS: Digitized radiofrequency ultrasound data were acquired from the kidneys of patients with biopsy-proven diffuse renal disease and transplant rejection (37 patients plus 18 normal volunteers). The results of the quantitative analysis were compared with histology results to determine if microscopic renal structure could be correlated with quantitative features such as scatterer size and scatterer spacing. The results also were analyzed using receiver operating characteristic analysis to determine if diffuse disease could be detected reliably using quantitative methods. RESULTS: The three most useful features in the native kidneys were mean scatterer spacing (MSS), sigma's, and average scatterer size (D). Using these features, it was possible to detect diffuse renal disease causing a decrease in renal function with an area under the ROC curve (Az) of 0.93. The feature D corresponded closely to histologically measured average glomerular diameters. For normals, D = 216 microns and glomerular diameter = 211 microns. No histologic correlate was found for scatterer spacing. In transplants, MSS and integrated backscatter were most useful for detecting rejection (Az = 0.87), and D in rejection was similar to the values for normal kidney and normally functioning transplants. CONCLUSIONS: The D value corresponds to glomerular diameter, and glomerular enlargement can be detected readily using quantitative ultrasound. Combinations of two to four quantitative features can detect diffuse renal disease and transplant rejection reliably.

Humans↗

Understanding the process of quantitative ultrasonic tissue characterization.

Because the human vision system cannot distinguish the broad range of gray values that a computer visual system can, computerized image analysis may be used to obtain quantitative information from ultrasonographic (US) real-time B-mode scans. Most quantitative US involves programming an off-line computer to accept, analyze, and display US image data in a way that enhances the detection of changes in small-scale structures and blood flow that occur with disease. Common image textural features used in quantitative US tissue characterization consist of first-order gray-level statistics (eg, occurrence frequency of gray levels independent of location or spatial relationship) and second-order gray-level statistics dependent on location and spatial relationship, including statistical analysis of gradient distribution, co-occurrence matrix, covariance matrix, run-length histogram, and fractal features. A customized tissue signature software has been developed to analyze image data obtained from clinical US scanners. Means comparison testing and multivariate analysis techniques are used to compare the numbers generated for a particular region of interest. By integrating these techniques into the radiologist's interpretation of the sonogram, the quantitative information gained may lead to earlier detection of lesions difficult to see with the human eye.

Humans↗

US tissue characterization workstation: applications and design.

This article discusses the purpose, design, and uses of an ultrasonographic tissue characterization workstation. The distinguishing characteristic of a tissue characterization workstation is its ability to analyze and classify image textures. Texture is defined as regularly or randomly repeating patterns. Small texture differences in an image are difficult to observe in the presence of noise. Therefore, it is necessary to analyze the image quantitatively. Quantitative measurements include run-length statistics, fractal dimension, and correlation statistics. The workstation is designed so that a radiologist can analyze the patient's images through an easy-to-use graphical user interface. The workstation software is based on standards, so that it can be run on a variety of different hardware platforms. The workstation can be used in a research environment to distinguish between images of malignant and benign breast lesions, which are difficult to diagnose visually. Further work is being done to make the workstation software into a useful clinical tool.

Image Processing, Computer-Assisted↗

Laparoscopic cholecystectomy. Postoperative sonographic findings.

Seventeen consecutive patients undergoing elective laparoscopic cholecystectomy (LC) were serially evaluated with transabdominal ultrasound before, one day after, and six days after LC to document what, if any, changes occur in the surgical bed and surrounding parenchyma. The most common postoperative finding was focal sonolucency in the hepatic parenchyma adjacent to the gallbladder fossa in six (35%) of 17 patients. Five patients (29%) had postoperative fluid collections in the gallbladder fossa; in four of these five, it was technically difficult to dissect the gallbladder from the liver at the time of original surgery. In one patient the fluid resolved by the sixth postoperative day. It persisted in the remaining four. Two patients had transient ductal dilation and one had pneumobilia. Shadowing and ring-down artifact was identified in 12 patients due to surgical clips in the triangle of Calot. Because gallbladder fossa fluid may persist up to six days after uncomplicated laparoscopic cholecystectomy, caution should be used before attaching significance to isolated imaging findings. Clinical judgement remains the best means of selecting which patients need additional evaluation.

Abdomen↗

The effects of a soft tissue mimicking medium and increased power settings on the location and magnitude of lithotripter peak positive pressure.

In vitro experiments showed that a tissue mimicking medium alters the peak positive pressure (p+), focal zone properties and frequency content of shockwaves compared with their behavior in water. The reduction in (p+) ranged from 5% at 10 kV. to 19% at 18.1 kV., when measured at the geometric focus with the tissue mimicking medium present. As power settings were increased, the relative gain in pressure was damped by attenuation. A 2 mm. shift in the acoustic focus was seen both axially and laterally with the tissue mimicking medium. While the former is probably not significant, the latter may be clinically significant given the narrow lateral beam width at the acoustic focus. These attenuation experiments suggest that clinical targeting through tissue may not be as precise or result in as high peak pressures as the clinician expects. Especially at high power settings, the depth of tissue traversed should be minimized to limit attenuation effects.

Biophysical Phenomena↗

Routine helical CT of the abdomen: image quality considerations.

PURPOSE: Both helical and nonhelical abdominal computed tomographic (CT) scans were obtained to compare image quality, study the effect of patient size and collimation, and compare the frequency of visualization of normal abdominal structures. MATERIALS AND METHODS: The study group consisted of 60 consecutive patients with clinically suspected metastatic malignancy. RESULTS: Both helical and nonhelical image quality was excellent, with equal mean image quality scores of 4.1 on a 5-point scale. In patients weighing more than 175 lb (79 kg), both helical and nonhelical image quality degraded equally when 5-mm collimation was used; 10-mm collimation resulted in excellent image quality, regardless of patient size. Small in-plane structures (eg, renal arteries, renal veins, pancreatic duct) were seen best on helical scans. With the addition of retrospectively reconstructed overlapping images, improvement in visualization of these structures was statistically significant. CONCLUSION: Helical CT scanning should be the preferred means of acquiring routine abdominal CT images.

Abdominal Neoplasms↗

Improving the distinction between benign and malignant breast lesions: the value of sonographic texture analysis.

To improve the ability of ultrasound to distinguish benign from malignant breast lesions, we used quantitative analysis of ultrasound image texture. Eight cancers, 22 cysts, 28 fibroadenomata, and 22 fibrocystic nodules were studied. The true nature of each lesion was determined by aspiration (for some cysts) or by open biopsy. Analysis of image texture was performed on digitized video output from the ultrasound scanner using fractal analysis and statistical texture analysis methods. The most useful features were those derived from co-occurrence matrices of the images. Using two features together (contrast of a co-occurrence matrix taken in an oblique direction, and correlation of a co-occurrence matrix taken in the horizontal direction), it was possible to exclude 78% of fibroadenomata, 73% of cysts, and 91% of fibrocystic nodules while maintaining 100% sensitivity for cancer. These findings suggest that ultrasonic image texture analysis is a simple way to markedly reduce the number of benign lesion biopsies without missing additional cancers.

Adolescent↗

Hepatic cavitation. A marker of transient hepatocellular injury during biliary lithotripsy.

Sonographically visible microbubbles attributable to cavitation effects have been observed in bile (within the gallbladder), in hepatic vessels, and within the liver of patients undergoing biliary lithotripsy. Cavitation effects are believed to contribute to stone fragmentation and possibly tissue injury during lithotripsy. To study the latter, the relationship between intraparenchymal hepatic cavitation and serum transaminase activity and clinical follow-up was analyzed in 81 patients undergoing 164 lithotripsy treatments. Seventy-one treatments (43%) resulted in sonographically evident microbubbles in the liver parenchyma during lithotripsy. A temporary, yet statistically significant (P < 0.01) rise in SGOT and SGPT was observed within 2 hr of completion of lithotripsy compared to those patients without hepatic microbubbles. All but one patient had a return to pretreatment baseline levels of SGOT and SGPT by two weeks after lithotripsy. In this patient, persistent elevation of transaminases was attributed to the delayed passage of fragments and not to any sequelae from hepatic cavitation effects. Ultrasound immediately after, two weeks after, and 3-12 months after lithotripsy showed no hepatic structural abnormalities. Ursodiol administration at the time of treatment did not predispose to hepatic cavitation or elevation of transaminase. Detection of hepatic microbubbles during lithotripsy is a marker of hepatocellular injury. Their correlation with transaminase elevation refutes the contention that transaminasemia results solely from fragment passage after lithotripsy. Although not associated with recognizable structural damage or long-term sequelae, cavitation effects and transaminasemia reiterate that shockwaves are not entirely benign as they traverse parenchymal organs.

Alanine Transaminase↗