[Current trends and problems in the measurement of limb loading parameters during transosseous osteosynthesis using external fixation devices].

The problem in question is whether it is reasonable to equip a conventional limb external fixation apparatus with means for the diagnosis of loading parameters: the forces and displacement of the opposite supporting elements of the apparatus. It is assumed that during distraction osteogenesis it is expedient to apply load to the limb by the load rate only at the initial stage of callus regeneration (the plastic or slightly elastic mechanical state) while the most effective way to do so is to act force at later stages. A number of functions derived from the modified parameters which might aid a physician to choose the optimum limb loading parameters at different stages of treatment were considered by using as example a hypothetical ring-type apparatus equipped with means for continuous measurement of current forces applied to the apparatus and current displacements of opposite ring blocks. Specifications for the measuring system of loading parameters were defined by using an Ilizarov apparatus as an example and why possible rough measurement errors may occur is revealed. The paper shows it necessary to develop methods for calculation of parasitic deformations, i.e. those of the loaded elements of the apparatus for the evaluation of the reciprocal displacement of bone fragments.

Biomechanical Phenomena↗

[Organizing diagnosis of parameters of limb loading during transosseous osteosynthesis by external fixation devices].

The presented system for compression-traction osteosynthesis (CTS) involves a modified Ilizarov apparatus, a set of force and length detectors, PC controlled measuring system, a set of cables and original software. The system apparatus allows for angular displacement of bone fragments in the range of +/- 30 degrees or 0-60 degrees and lateral displacement of bone fragment edges in the joint along any azimuth in the ring plane. It was mathematically proved that the axial and angular displacement of the two apparatus ring blocks relative to each other can be described with three parameters: axial displacement of the ring center, the ring deflection (turn) angle and the ring axis turn azimuth (angle). Formulas for calculation of the displacement of three pairs of displacement control nuts so the plane of the fracture displacement angle (correction) cross the axis of the required ring plane turn azimuth (angle) were deduced for the reciprocal angular displacement of the bone fractures. No additional removable joints or the apparatus reconstruction for angular fracture displacement are needed. The CTS features the display of the current reciprocal position of bone fragment axes during the course of apparatus loading on the PC monitor.

Biomechanical Phenomena↗

[Determination of limb loading parameters on standard external fixators].

For the compression-traction osteosynthesis system CTS, the grounds for evaluating the existing parasitic deformity of loaded apparatus elements, such as pins and rings are shown. The measuring procedure for testing the axial and angular rigidity of a regenerate zone is presented. The angular rigidity is estimated by the ellipse of rigidities, i.e. by three parameters: a vector of the maximum rigidity (CU), a vector of the minimum rigidity (CV) and an azimuth of CU position in the ring plane. Some more useful functions of CTS, including the posthospital treatment of patients are described.

Biomechanical Phenomena↗