PubMed Health⌕ Search

Biomedical subjects

B Saam

Publications and source records attributed to B Saam.

15 recordsLinked to original sources

Wall relaxation of 3He in spin-exchange cells.

The 3He longitudinal spin-relaxation rate T1-1 is crucial for production of highly polarized 3He by spin-exchange optical pumping. We show that T1-1 is increased by a factor of 2-20 solely by exposure of spin-exchange cells to a few-kG magnetic field. The original T1-1 can be restored by degaussing the cell. The effect is attributed to magnetic surface sites and has been observed in both Pyrex and aluminosilicate-glass cells. Our results both advance the understanding of wall relaxation and demonstrate the use of 3He as an extremely sensitive probe of surface magnetism.

Journal Article↗

Dynamic echo planar MR imaging of lung ventilation with hyperpolarized (3)He in normal subjects and patients with severe emphysema.

We applied the rapid imaging capability of echo planar MR pulse sequences and hyperpolarized (3)He ventilation imaging to observe the dynamic distribution of gas in the lungs during breathing. Findings in five normal volunteers (age 19-53 years) and four patients with severe smoking-related emphysema (age 56-71 years) were compared. All studies were performed on a 1.5 T whole body scanner using a 30 cm Helmholtz surface coil and 0.5 l of 20-40% polarized (3)He mixed with 1-2 l nitrogen. Our echo planar imaging pulse sequence allowed acquisition of each image in 0.04 s, with a pixel size of 7 mm(2) (TR = 40.5 ms, TE = 12.1 ms, flip angle = 22 degrees, echo train length = 32, matrix = 32 x 64, field of view = 225 x 450 mm, slice thickness = 10 mm). Imaging was performed in the transaxial plane repeatedly at 3, 10 or 20 evenly spaced levels, immediately before and during breathing of the gas mixture. In normal subjects during the first breath, (3)He appeared throughout each slice first in the mid lungs, then in the lower lungs, then in the upper lungs, with slightly greater signal in the dependent posterior regions. In patients with emphysema, sequential filling of different lung regions was seen during the first breath, with delayed filling of other regions observed during rebreathing and room air washout. We conclude that subsecond dynamic (3)He MR ventilation imaging can reveal normal and abnormal ventilation phenomena not seen with conventional scintigraphic methods, and offers another approach to the study of ventilation physiology and pathophysiology.

Adult↗

Rapid imaging of hyperpolarized gas using EPI.

Rapid repetitive MRI of hyperpolarized (HP) gases using echo-planar imaging (EPI) has been theoretically investigated and experimentally demonstrated for (3)He in human lung. A quantitative treatment of signal attenuation and magnetization consumption for the unique circumstance of a rapidly diffusing nonrenewable magnetization source has been performed. Rapid (compared to the human respiratory cycle) and repetitive imaging of the lung gas space with EPI and a single delivered bolus of HP-(3)He is feasible using low flip angles, provided the voxels are not too small. A coarse-grid (32 x 64) EPI pulse sequence has been developed and implemented to image the lungs of healthy volunteers during rebreathing of a HP-(3)He/N(2) gas mixture. A set of three 10-mm axial slices was imaged every 0.12 sec for the 36 sec duration of rebreathing, yielding a real-time visualization of ventilation. Despite some mild artifacts, the images are of good quality and show changes in gas density related to respiratory physiology. Magn Reson Med 42:507-514, 1999.

Echo-Planar Imaging↗

Dynamics of magnetization in hyperpolarized gas MRI of the lung.

The magnetization in hyperpolarized gas (HP) MRI is generated by laser polarization that is independent of the magnet and imaging process. As a consequence, there is no equilibrium magnetization during the image acquisition. The competing processes of gas inflow and depolarization of the spins lead to large changes in signal as one samples k-space. A model is developed of dynamic changes in polarization of hyperpolarized 3He during infusion and in vivo imaging of the lung and verified experimentally in a live guinea pig. Projection encoding is used to measure the view-to-view variation with temporal resolution < 4 ms. Large excitation angles effectively sample the magnetization in the early stages of inflow, highlighting larger airways, while smaller excitation angles produce images of the more distal spaces. The work provides a basis for pulse sequences designed to effectively exploit HP MRI in the lung.

Animals↗

Longitudinal relaxation and diffusion measurements using magnetic resonance signals from laser-hyperpolarized 129Xe nuclei.

Methods for T1 relaxation and diffusion measurements based on magnetic resonance signals from laser-hyperpolarized 129Xe nuclei are introduced. The methods involve optimum use of the perishable hyperpolarized magnetization of 129Xe. The necessary theoretical framework for the methods is developed, and then the methods are applied to measure the longitudinal relaxation constant, T1, and the self-diffusion constant, D, of hyperpolarized 129Xe. In a cell containing natural abundance 129Xe at 790 Torr, the T1 value was determined to be 155 +/- 5 min at 20 degrees C and at 2.0 T field. For a second cell at 896 Torr, at the same field and temperature, the T1 value was determined to be 66 +/- 2 min. At a higher field of 7.05 T, the T1 values for the two cells were found to be 185 +/- 10 and 88 +/- 5 min, respectively. The 129Xe self-diffusion constant for the first cell was measured to be 0.057 cm2/ s and for the second cell it was 0.044 cm2/s. The methods were applied to 129Xe in the gas phase, in vitro; however, they are, in principle, applicable for in vivo or ex vivo studies. The potential role of these methods in the development of newly emerging hyper-polarized 129Xe MRI applications is discussed.

Animals↗

Human lung air spaces: potential for MR imaging with hyperpolarized He-3.

Two healthy volunteers who had inhaled approximately 0.75 L of laser-polarized helium-3 gas underwent magnetic resonance imaging at 1.5 T with fast gradient-echo pulse sequences and small flip angles ( < 10 degrees). Thick-section (20 mm) coronal images, time-course data (30 images collected every 1.8 seconds), and thin-section (6 mm) images were acquired. Subjects were able to breathe the gas (12% polarization) without difficulty. Thick-section images were of good quality and had a signal-to-noise ratio (S/N) of 32:1 near the surface coil and 16:1 farther away. The time images showed regional differences, which indicated potential value for quantitation. High-resolution images showed greater detail and a S/N of approximately 6:1.

Adult↗

MR imaging with hyperpolarized 3He gas.

Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system offers great promise for eventual in vivo imaging experiments. Fast 2D and 3D GRASS sequences with very small flip angles were employed to conserve the norenewable longitudinal magnetization. We discuss various unique features associated with performing MRI with hyperpolarized gases, such as the selection of the noble gas species, polarization technique, and constraints on the MR pulse sequence.

Animals↗

Biological magnetic resonance imaging using laser-polarized 129Xe.

As currently implemented, magnetic resonance imaging (MRI) relies on the protons of water molecules in tissue to provide the NMR signal. Protons are, however, notoriously difficult to image in some biological environments of interest, notably the lungs and lipid bilayer membranes such as those in the brain. Here we show that 129Xe gas can be used for high-resolution MRI when the nuclear-spin polarization of the atoms is increased by laser optical pumping and spin exchange. This process produces hyperpolarized 129Xe, in which the magnetization is enhanced by a factor of about 10(5). By introducing hyperpolarized 129Xe into mouse lungs we have obtained images of the lung gas space with a speed and a resolution better than those available from proton MRI or emission tomography. As xenon (a safe general anaesthetic) is rapidly and safely transferred from the lungs to blood and thence to other tissues, where it is concentrated in lipid and protein components, images of the circulatory system, the brain and other vital organs can also be obtained. Because the magnetic behaviour of 129Xe is very sensitive to its environment, and is different from that of 1H2O, MRI using hyperpolarized 129Xe should involve distinct and sensitive mechanisms for tissue contrast.

Animals↗