PubMed Health⌕ Search

Biomedical subjects

B Sage

Publications and source records attributed to B Sage.

11 recordsLinked to original sources

Regional variations in skin barrier function and cutaneous irritation due to iontophoresis in human subjects.

The effect of saline iontophoresis on skin barrier function and irritation was investigated on three body sites (abdomen, chest and upper arm) in order to select an appropriate site for iontophoretic delivery of drugs. Thirty healthy human volunteers were recruited according to specific entry criteria. Ten subjects, five males and five females, were assigned to each body site group. Skin barrier function and irritation was examined after 4 h of saline iontophoresis at a current density of 0.2 mA/cm(2) on a 6.5 cm(2) area in terms of the measured responses: transepidermal water loss (TEWL), skin capacitance, skin temperature and visual scores. Alterations in TEWL due to iontophoresis were not observed in the upper arm and chest; however, changes in TEWL at the abdomen were observed and returned to baseline 2 h after patch removal. Similarly, changes in capacitance due to iontophoresis returned to baseline (P>0.05) at the three body sites 2 h after patch removal except under the anode at the abdomen (P<0.05). There was a significant increase in skin temperature due to iontophoresis at the anode and the cathode (P<0.05) at the upper arm. Edema was not observed. At patch removal, the erythema score was significantly (P<0.001) elevated in comparison to baseline at the three body sites. Erythema resolved within 24 h except at the chest under the anode, where the erythema score was still higher (P<0.01) than the baseline. Papules appeared in five subjects at the active anode site on the chest. In three of the subjects, these papules did not resolve until 24 h post patch removal. Thus, there was regional variation in the function of the skin and irritation due to iontophoresis. Irritation was greater at the chest than at the abdomen or upper arm.

Abdomen↗

Effect of saline iontophoresis on skin barrier function and cutaneous irritation in four ethnic groups.

The effect of saline iontophoresis on skin barrier function and irritation was investigated in four ethnic groups (Caucasians, Hispanics, Blacks and Asians). Forty healthy human volunteers were recruited according to specific entry criteria. Ten subjects, five males and five females, were assigned to each ethnic group. Skin barrier function was examined after 4 hours of saline iontophoresis at a current density of 0.2 mA/cm(2) on a 6.5 cm(2) area in terms of the measured responses: transepidermal water loss (TEWL), skin capacitance, skin temperature and visual scores. There were significant differences in TEWL among the ethnic groups prior to patch application. TEWL at baseline in ethnic groups was in the rank order: Caucasian>Asian>Hispanic>Black. Iontophoresis was generally well tolerated, and skin barrier function was not irreversibly affected by iontophoresis in any group. There was no significant skin temperature change, compared to baseline, in any ethnic groups at any observation point. Edema was not observed. At patch removal, the erythema score was elevated in comparison to baseline in all ethnic groups; erythema resolved within 24 hours. Thus, saline iontophoresis produced reversible changes in skin barrier function and irritation in healthy human subjects.

Adolescent↗

Microelectromechanical systems technology to deliver insulin.

A new microfabrication technology, microelectromechanical systems (MEMS), is envisioned for improved insulin delivery in the context of a device currently being developed for the Defense Advanced Research Projects Agency (DARPA). The drug delivery system utilizes MEMS technology to move and control fluids at the microscale, making possible the reconstitution and delivery of extremely small amounts of drug with extreme precision. In this article, the required microscale components that are currently being developed for the system are described. MEMS are made using fabrication methods similar to that utilized in microelectronics. Consequently, MEMS technology can be used to fabricate devices that are extremely small. The fundamental difference is that MEMS devices can either move themselves or control the movement of other materials, such as fluids. Furthermore, this manufacturing method is intrinsically low-cost and therefore is ideal for drug delivery systems. The current development of a new drug delivery system for controlled drug reconstitution and delivery system for DARPA is described as are the MEMS-based components for the required fluidic control. The adaptation of the system for insulin delivery is addressed and is envisioned to be a fully self-contained parenteral drug delivery system about the size of a 4-mm thick credit card.

Diabetes Mellitus, Type 1↗

The effect of saline iontophoresis on skin integrity in human volunteers. I. Methodology and reproducibility.

This study, conducted in 36 human volunteers, was an evaluation of the effects of saline iontophoresis on skin temperature, irritation, and barrier function. The major objectives were to assess the effects of low-level ionic currents, to validate the proposed methodology of assessment, and to establish reproducibility in repeated saline iontophoresis applications. This was the first of a multistage study designed to assess the safety of 24-hr saline iontophoresis episodes at selected currents and current densities. Since an iontophoresis patch challenges the skin barrier both by occluding the skin surface and by passing ionic current through the skin, the experimental protocol was designed to permit measurement of the contribution of each of these processes to the overall response. In this first stage we investigated the effect of 10 min of current delivery, at 0.1 mA/cm2 on a 1-cm2 area patch and 0.2 mA/cm2 on a 6.5-cm2 area patch compared to unpowered control patches. Twelve subjects were tested under each condition on two separate occasions to examine reproducibility of the response variable measurements. A further 12 subjects were tested once under the 0.2 mA/cm2, 6.5-cm2 condition. Skin irritation was evaluated via repeated measurements of transepidermal water loss, capacitance, skin temperature, skin color, and a visual scoring system, before the iontophoresis episode and after patch removal. No damage to skin barrier function in terms of skin-water loss or skin-water content was detected. Slight, subclinical, short-lasting erythema was observed for both conditions. Assessment of correlation coefficients showed highly statistically significant indications of reproducibility for all five response variables measured. The experimental design, in combination with a repeated measures analysis, provided clear separation of the occlusion and ionic current components of the iontophoretic patch challenge. Further, the repeated measures analysis gave a highly sensitive assessment of skin irritation and resolution after patch removal. We conclude that the experimental methodology is appropriate for assessing possible changes in skin integrity resulting from saline iontophoresis under similar operating conditions for longer durations and for other skin challenges from which a subclinical response is expected.

Body Temperature↗

Effects of vasoactive drugs on transdermal lidocaine iontophoresis.

The effect of co-administration of vasoactive drugs on the transdermal iontophoretic delivery of lidocaine.HCI was studied in in vitro cells, in the isolated perfused porcine skin flap (IPPSF), and in vivo in pigs. Iontophoresis of lidocaine in vitro across human and porcine skin were similar, supporting the use of porcine skin as an appropriate animal model. Co-iontophoresis of the vasodilator tolazoline marginally decreased lidocaine flux in vitro, but significantly increased it in the IPPSF and in vivo. In contrast, norepinephrine decreased lidocaine flux in the IPPSF. Vasomodulation also changed the shape of the venous efflux profile in the IPPSF as evidenced by changes in fractional absorption index, as well as the AUC. These studies demonstrate that co-iontophoresis of vasoactive compounds may significantly alter the transdermal delivery of lidocaine and that use of vitro animal model systems which possess a functional microcirculation are essential to study this process if reliable extrapolation to the in vivo setting is desired.

Administration, Cutaneous↗

Use of durapatite for the rehabilitation of resorbed alveolar ridges.

These investigations were undertaken to evaluate durapatite, a particulate, ceramic, nonresorbable bone-grafting material for augmentation of deficient alveolar ridges. A total of 207 augmentations were reported among 198 patients over 24 months. Subjective and objective data showed that durapatite alone was successful for all classes of ridges augmented; height, bulk, contour, and ridge form generally improved and soft tissue overlying the augmented ridges was firm and immobile. Impressions for dentures usually began 4 to 6 weeks after surgery and these dentures remained stable, retentive, and esthetically pleasing throughout the study. Other than transiently altered sensations resulting from mental nerve manipulation during surgery, no other important procedural complications were noted. No infection or bone resorption beneath the implant was observed throughout these studies. Durapatite used in an outpatient setting provides a less costly and more permanent method for alveolar ridge augmentation than do augmentation procedures using autogenous or banked bone.

Adult↗

The ovary as a source of alpha-ecdysone in an adult mosquito.

The ovaries of the mosquito Aedes aegypti cultured in vitro secrete material that behaves like ecdysone in a radioimmunoassay. The material was identified as alpha-ecdysone by high-resolution liquid and gas-liquid chromatography. Secretion reached a maximum 16 hr after a blood meal as shown by bioassay and direct determination. Ovariectomy reduced the concentration of ecdysone in the adult after a blood meal. Qualitative analysis of whole-body extracts indicated beta-ecdysone to be the principal species present. Thus the ovaries appear to secrete a prohormone, alpha-ecdysone, which is converted to beta-ecdysone. Beta-ecdysone plays a significant role in stimulating egg development in the adult mosquito and may have reproductive roles in other insects.

Adipose Tissue↗