PubMed Health⌕ Search

Biomedical subjects

B Schmauss

Publications and source records attributed to B Schmauss.

3 recordsLinked to original sources

Principle, validity, and reliability of scanning laser Doppler flowmetry.

PURPOSE: The objective of this study is to present the reliability and validity of scanning laser Doppler flowmetry (SLDF) performing a high-definition topography of perfused vessels of the retina and the optic nerve head with simultaneous evaluation of blood flow. METHODS: The examination of blood flow by SLDF is based on the optical Doppler effect. The data acquisition and evaluation system is a modified laser scanning device; the wavelength of the laser source is 670 mm, with a power of 100 microW (Heidelberg Engineering, HRF). The reliability of SLDF was estimated by performing five separate measurements in 10 eyes on 5 days. The validity of the method was tested by two experiments. First, in an experimental set-up, the capability of SLDF to measure the velocity of a moving plane in absolute units was estimated. Second, comparative measurements were performed of retinal blood flow in normal eyes and in 33 glaucomatous eyes with SLDF and a commercially available single-point laser Doppler flowmeter (Oculix). RESULTS: We found SLDF to produce a high reliability. The reliability coefficients r1 of flow, volume, and velocity were 0.82, 0.81, and 0.83, respectively. Comparative measurements of the retinal blood flow by SLDF and a single-point laser Doppler flowmeter of corresponding retinal points showed a linear and significant relationship between flow (r = 0.83, p < 0.0001), volume (r = 0.51, p < 0.0001), and velocity (r = 0.59, p < 0.0001). In the experimental set-up, SLDF was able to quantitatively measure velocity in absolute units. CONCLUSIONS: SLDF enables the visualization of perfused vessels of the juxtapapillary retina and the optic nerve head in high resolution by two-dimensional mapping of the optical Doppler shift and a reproducible evaluation of capillary blood flow.

Evaluation Studies as Topic↗

[2-dimensional mapping and retinal and papillary microcirculation using scanning laser Doppler flowmetry].

PURPOSE: To present clinical applications of a new non-invasive method imaging in a high-definition the topography of perfused retinal vessels. METHOD: By a combination of a laser Doppler flowmeter with a scanning laser system the perfusion of the retina and the optic nerve head is visualized and quantified. The principles of measuring blood flow by Laser Doppler Flowmetry are based on the optical Doppler effect: laser light scattered by a moving particle is shifted in frequency by an amount delta f. Our data acquisition and evaluation system is a modified laser scanning tomograph. The technical data are: retinal area of measurement 2.7 mm x 0.7 mm, 10 degree-field with 256 points x 64 lines, measurement accuracy 10 microns, wavelength 670 nm and 790 nm, light power 100 microW, data acquisition time 2,048 s. Every line is scanned 128 times by a line-sampling rate of 4,000 Hz. By performing a discrete Fast Fourier Transformation over 128 intensities of each retinal point the laser Doppler-shift is calculated for each retinal point. With these data a 2-D map with 256 x 64 points of the retinal perfusion is created. The brightness of the picture-point is coded by the value of the Doppler shift. We estimated the reliability and the validity of the method. Perfusion-pictures of the superficial retinal layer and in the optic nerve head were presented. RESULTS: The reliability-coefficients r1 of "Flow", "Volume" and "Velocity" were 0.85, 0.83, and 0.85 respectively. The blood flow measurements by the presented method ("Scanning Laser Doppler Flowmetry") in an artificial capillary gave a linear relationship (r-value 0.973, p < 0.00001) between defined blood velocities and the measured blood flow. By the confocal technique, dependent on the focus, capillaries of the retinal superficial vasculature of the optic nerve head became visible with a high resolution. Off line the blood flow of areas of 110 microns x 110 microns were calculated in terms of laser Doppler flowmetry. CONCLUSION: "Scanning Laser Doppler Flowmetry" facilitates the visualisation of perfused retinal capillaries and vessels in high resolution. The representation of the function of the retinal circulation by SLDF leads to an image similar to the anatomical situation. The 2-dimensional mapping of local blood flow leads to a physiological picture of the retinal perfusion with visible vessels and capillaries.

Adult↗

Two dimensional mapping of the perfusion of the retina and optic nerve head.

AIM: To present a new non-invasive method of performing a high definition topography of perfused vessels of the retina and the optic nerve head with simultaneous evaluation of blood flow. METHOD: By a combination of a laser Doppler flowmeter with a scanning laser system the perfusion of the retina and the optic nerve head is visualised. The principles of measuring blood flow by laser Doppler flowmetry are based on the optical Doppler effect: laser light scattered by a moving particle is shifted in frequency by an amount delta f. Our data acquisition and evaluation system is a modified laser scanning tomograph. The technical data are retinal area of measurement 2.7 mm x 0.7 mm, 10 degrees field with 256 points x 64 lines, measurement accuracy 10 microns, wavelength 670 nm and 790 nm, light power 100 microW and 200 microW, data acquisition time 2.048 s. Every line is scanned 128 times by a line sampling rate of 4000 Hz. By performing a discrete fast Fourier transformation over 128 intensities of each retinal point the laser Doppler shift is calculated for each retinal point. With these data a two dimensional map with 256 x 64 points of the retinal perfusion is created. The brightness of the pixel is coded by the value of the Doppler shift. Offline capillary blood flow is estimated in arbitrary units according to the theory of laser Doppler flowmetry in every region of interest of the perfusion picture. We estimated the reliability and the validity of the method. Retinal blood flow was measured by scanning laser Doppler flowmetry (SLDF) while varying intraocular pressure by a suction cup of three healthy volunteers. Measurements of retinal blood flow performed in 47 eyes by the presented method (SLDF) were correlated with data gained by a commercially available laser Doppler flowmeter. Perfusion pictures of the superficial retinal layer and of deep prelaminar layers in the optic nerve head are presented. RESULTS: The reliability coefficients r1 of 'flow', 'volume', and 'velocity' were 0.84, 0.85, and 0.84 respectively. We found a significant linear relation between SLDF flow and the ocular perfusion pressure (r = 0.84, p < 0.001). Comparative measurements of the retinal blood flow by SLDF and a commercially available laser Doppler flowmeter showed a linear and significant relation (flow r = 0.6, p < 0.0001, volume r = 0.4, p < 0.01). Capillaries of the retinal superficial vasculature or deep ciliary sourced capillaries of the optic nerve head became visible with a high resolution by the confocal technique dependent on the focus. Offline, the blood flow variables of areas of 100 microns x 100 microns were calculated. CONCLUSION: SLDF enables the visualisation of perfused capillaries and vessels of the retina and the optic nerve head in high resolution by two dimensional mapping of perfusion variables which are encoded by the Doppler signal. This method achieves simultaneously qualitative and quantitative evaluation of capillary blood flow of distinct areas of the capillary meshwork.

Humans↗