Clonal spread of meropenem-resistant Acinetobacter baumannii strains in hospitals in the Mediterranean region and transmission to South-west Germany.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to B Schulte.
Explore the source record for details and available documents.
The incidence of vancomycin-resistant Enterococcus faecium isolation was low (<or=5%) in German hospitals before 2003. Within the second half of 2003 and the first half of 2004, however, increasing frequencies of up to 14% were noticed in several hospitals in southwestern Germany. This increase was attributed mainly to the occurrence and spread of epidemic-virulent ampicillin/vancomycin-resistant, vanA- and vanB-positive E. faecium clones, most of which exhibited the virulence factors enterococcal surface protein (esp) and bacteriocin activity and some which exhibited hyaluronidase (hyl). E. faecium possessing hyaluronidase was initially found in U.S. hospitals and recently detected in several European hospitals and, subsequently, in German hospitals as well. Ampicillin/vancomycin-resistant E. faecium clones originating mainly from southwestern German hospitals were characterized by multilocus sequence typing since different sequence types (STs) belonging to the clonal complex-17 are currently disseminated worldwide. Multilocus sequence typing revealed that, in 1998 and 1999, ampicillin/vancomycin-resistant E. faecium clone ST-117 was prevalent in various German hospitals, while in 2003 and 2004, clone ST-203 dominated in several hospitals located in southwestern Germany. Both sequence types display single-locus variants of ST-78, which was frequently recorded in various Italian hospitals between 2000 and 2003, and all of these STs belong to the clonal complex-17. Expression of linezolid resistance was observed in ampicillin/glycopeptide-resistant E. faecium strains (VanA type) from two tertiary hospitals in southwestern Germany due to mutations in domain V of the 23S rDNA (G2576T). While in one hospital the resistance emerged during linezolid therapy, in the other hospital resistance was caused by transfer of an identical linezolid/ampicillin/glycopeptide-resistant E. faecium strain. In conclusion, it is very important to monitor the occurrence of epidemic-virulent clonal complex-17 strains of E. faecium to prevent their spread in hospitals, especially if they are resistant to glycopeptides and linezolid.
AIM: The aim of the study was to analyze the medical history of patients with AV-nodal reentry tachycardia (AVNRT). PATIENTS AND METHODS: Between 1990 and 1999 radiofrequency catheter ablation was performed in 1,024 patients suffering from AVNRT. Data of the previous history were comprehended by questionnaire. RESULTS: 748 (73%) patients replied to the questionnaire. The interval between the first appearance of the symptoms and the catheter ablation was 4.1 +/- 1.5 years. The mean age of the patients was 55.4 years (female) and 58.7 years (male). Merely 6% of all patients had a structural heart disease. The mean duration of case history was 16.8 years. In comparison to the male patients, the assignment for female patients to catheter ablation was after a significant 7 years longer lasting anamnesis. The distribution of age showed that the first tachycardia appeared in 16% of the female patients older than 50 years of age and only in 17% younger than 20 years of age; the corresponding percentages for men were 31% and 18%. With reference to the duration of the longest tachycardia episodes and arrhythmia-related presyncopes and syncopes, women showed a more defined symptomatic. On 20% of the patients a radiofrequency catheter ablation ensued without previous antiarrhythmic treatment; 80% of the patients were treated with 2.8 different antiarrhythmic medications. Medical consultations regarding AVNRT were named as follows (mean/range): family doctor 6.1/1-250, emergency physicians 1.1/0-15, hospital 1.0/0-20. The indication for catheter ablation was set by the family doctor in 13% and by the cardiologist in 77%. Patients got their information about catheter ablation in 2.9% from acquainted persons or news services. CONCLUSION: There is no "typical" anamnesis of AVNRT patients. There is an amazingly high rate of patients with an AVNRT begin in elder stage of age and the fact of therapy delay of 7 years in behalf of women.
Intercellular adhesion molecule (ICAM)-1 is involved in forming the immunological synapse. The contribution of ICAM-1 to immune responses is not critical because mice with a disrupted ICAM-1 gene do not have grossly abnormal immune reactivity. Here we report on the surprising finding that diabetes-prone NOD mice with a disrupted ICAM-1 gene (ICAM-1(-/-)) are completely protected from disease development. While 64% of ICAM-1(+/+) and 44% of ICAM-1(+/-) female NOD mice developed overt diabetes until 310 days old, no ICAM-1(-/-) NOD mice became hyperglycaemic. Histological examinations revealed minor infiltration around pancreatic islets of ICAM1(-/-) NOD mice. Administration of cyclophosphamide caused a progression to severe islet destruction in ICAM-1(+/+) NOD mice within 10 days. In contrast, ICAM-1(-/-) mice showed only mild insulitis. Furthermore, ICAM-1(+/+) NOD mice showed an increase of IFN-gamma, interleukin (IL)-12p40 and IL-12p35 pancreatic mRNA levels, leading to an increased ratio of IFN-gamma: IL-4 and IL-12p40: IL-12p35 expression. In contrast, ICAM-1(-/-) NOD mice did not upregulate IFN-gamma or IL-12p40 gene expression but maintained IL-4 and increased IL-12p35 gene expression. These results identify a dominant and non-redundant role of ICAM-1 in the development of autoimmune diabetes.
Nonadequate arrhythmia detection and delivery of electrical therapy is still a main problem in current implantable cardioverter defibrillator therapy. Besides supraventricular arrhythmias extra-cardiac biosignals also can cause inadequate shock delivery. The present study focuses on nonadequate arrhythmia detection due to oversensing of diaphragmatic myopotentials. Their clinical characteristics, incidence and management are presented. Three-hundred-eighty-four recipients of a transvenous cardioverter-defibrillator who were implanted and followed-up at our institution between October 1991 and June 1999 were enrolled. During a mean follow-up of 32+/-25 months a total number of 139 nonadequate episodes of arrhythmia detection due to oversensing of diaphragmatic myopotentials were observed in 33 patients (8.6%). In 11 patients a total of 32 high energy shock deliveries occurred. Oversensing of diaphragmatic myopotentials was primarily observed in patients implanted with defibrillator leads providing "integrated bipolar" sensing. The vast majority of nonadequate arrhythmia detection were observed during intrinsic bradycardia heart rate and/or antibradycardia pacing. Electrical lead failure was ruled out in every patient. In 90% of the patients with a cardioverter-defibrillator providing programmable maximal sensitivity (n=16), the reduction of maximum sensitivity was effective in preventing further episodes of nonadequate arrhythmia detection. In 48% of the patients with devices without programmable maximal sensitivity (n=17), surgery revision was necessary to solve the problem.
Escherichia coli hemolysin (HlyA) is a membrane-permeabilizing protein belonging to the family of RTX-toxins. Lytic activity depends on binding of Ca2(+) to the C-terminus of the molecule. The N-terminus of HlyA harbors hydrophobic sequences that are believed to constitute the membrane-inserting domain. In this study, 13 HlyA cysteine-replacement mutants were constructed and labeled with the polarity-sensitive fluorescent probe 6-bromoacetyl-2-dimethylaminonaphthalene (badan). The fluorescence emission of the label was examined in soluble and membrane-bound toxin. Binding effected a major blue shift in the emission of six residues within the N-terminal hydrophobic domain, indicating insertion of this domain into the lipid bilayer. The emission shifts occurred both in the presence and absence of Ca2(+), suggesting that Ca2(+) is not required for the toxin to enter membranes. However, binding of Ca2(+) to HlyA in solution effected conformational changes in both the C-terminal and N-terminal domain that paralleled activation. Our data indicate that binding of Ca2(+) to the toxin in solution effects a conformational change that is relayed to the N-terminal domain, rendering it capable of adopting the structure of a functional pore upon membrane binding.
A patient with recurrent syncope due to polymorphic ventricular tachycardia was diagnosed with Brugada syndrome. Programmed right ventricular stimulation could not induce arrhythmia. Epicardial stimulation from a left ventricular site through the coronary sinus led to polymorphic VT. The stimulation protocol for risk stratification in Brugada syndrome is discussed.
The aim of study was to investigate the extent of myocardial injury incurred by creation of continuous RF current induced linear ablation lesions (LL; ablation of atrial fibrillation, right atrial procedure) in comparison to focal RF lesions (FL; AV node reentry tachycardia, WPW tachycardia). In 23 patients with LL (age 51.3 +/- 11.2 years, 18 men, 5 women) and in 16 patients with FL (age 53.9 +/- 5.1 years, 8 men and 8 women), levels of creatine kinase (CK), myoglobin (MG), CKMB mass (CKMB M), CKMB activity (CKMB A), and cardiac troponin T (cTnT) were determined before and 2, 4, 8, 24, and 48 hours after ablation. CKMB A was normal in 87% in LL and 100% in FL (< 6% of CK) with median maximum CK values of 214 (45-1583) U/L in LL and 36 (29-212) U/L in FL. Peak values of all parameters were significantly higher in LL than in FL. The sensitivity of cTnT was 50% in FL and 100% in LL. In FL MG, total CK, and CKMB M were abnormal in only 12.5% of cases while in LL MG and CKMB M were pathological in 100% and total CK was abnormal in 91.3% of patients. The amount of energy and number of RF applications correlated with cTnT, MG, and CKMB M (P = 0.01). In conclusion, (1) long linear RF current lesions for ablation of atrial fibrillation are associated with significantly greater myocardial injury than focal ablations. (2) In focal lesions only cTnT provided a sensitivity of 50% in the detection of myocardial injury while in linear lesions cTnT, CKMBM, and CKMB M seemed suitable for detection of RF current induced myocardial damage with 100% sensitivity. All biochemical parameters do not differentiate patients with coronary ischemia up to 48 hours after an ablation. (3) Further investigations are necessary to determine if RF current linear lesions lead to impaired atrial contractility in cases of extensive tissue damage.
Inappropriate therapy of SVTs by ICDs remains a major clinical problem despite enhanced detection criteria like "sudden onset" and "rate stability" in third-generation devices. Electrogram morphology discrimination offers an additional approach to improve discrimination of supraventricular tachycardia (SVT) from ventricular tachycardia (VT). In a prospective, multicenter study, patients received an ICD with a beat-to-beat algorithm for morphological analysis of the intracardiac electrogram (Morphology Discrimination, MD). A nominal programmingfor standard enhancement criteria and morphology discrimination was required at implant. Electrogram storage of tachycardia episodes irrespective of delivery of therapy was used to assess sensitivity and specificity of the morphology algorithm alone and in combination with established detection criteria. During a 126 6-month follow-up, 886 episodes of device stored electrograms from 82 of 256patients were evaluated. Atnominal settings, the MD algorithm correctly identified 423 of 551 episodes as VT resulting in sensitivity of 77%. The classification of SVT was met in 239 of 335 episodes resulting in specificity of 71%. In combination with sudden onset, sensitivityincreased to 99.5% at the expense of specificity (48%). In conclusion, SVT-VT discrimination based on morphological analysis alone results in limited sensitivity and specificity. Programming the monitor mode allows individual assessment of the performance of this detection enhancement feature during clinical follow-up without compromising device safety. Only in patients with documented efficacy of morphology discrimination should this feature be subsequently activated.
AIMS: The aim of the study was to compare the defibrillation energy requirements and the probability of successful defibrillation at multiples of the minimum defibrillation energy requirements in active pectoral implantable defibrillators with single- and dual-coil lead systems. METHODS AND RESULTS: Eighty-three consecutive patients undergoing implantation of an active pectoral cardioverter-defibrillator were randomized to receive a dual- or single-coil lead system. Defibrillators of two manufacturers with a fixed tilt biphasic defibrillation waveform were used. Defibrillation energy requirements were determined using a step-down defibrillation testing protocol. According to the randomization protocol, the patients were assigned to three additional consecutive defibrillation attempts during device implantation and during pre-discharge testing of either 1.0, 1.5 or 2.0 times the determined defibrillation energy requirement. Patients presenting defibrillation energy requirements > 15 J were excluded from analysis. Eighty of 83 patients (96%) completed the study protocol. Three patients were excluded due to elevated defibrillation energy requirements. The defibrillation energy requirements in the dual- and single-coil patient groups were 8.0 +/- 3.6 J and 8.4 +/- 3.7 J (ns), respectively. A comparable percentage of study patients showed defibrillation energy requirements <10 J (dual-coil: 88% vs single-coil: 83%). Defibrillation impedance was significantly different (dual-coil: 50 +/- 5.8 Ohm; single-coil: 39.8 +/- 4.2 Ohm). Regarding the probabilities of successful defibrillation, there were no significant differences between the two patient groups. The probabilities of defibrillation at the three multiples of the defibrillation energy requirement using a dual- and single-coil lead system were 82, 89.7 and 93.6 and 77.8, 94.1 and 95.8%, respectively (P=0.88, P=0.42, P=0.62, respectively). CONCLUSIONS: Dual- and single-coil active pectoral defibrillator systems show no difference in defibrillation energy requirements and no difference in the probability of successful defibrillation at multiples of the minimum defibrillation energy requirement. The use of more simplified defibrillator lead systems may contribute to a future lead design focusing on improvement in lead durability.
AIMS: Thermal injury of subendocardial tissue leads to a release of electrolytes and free radicals from the intracellular site creating a change in electrochemical potential (eP) between the distal and the proximal catheter tip electrodes. The aim of the study was to verify the detection of ablation-induced release of electrolytes and free radicals and to assess the suitability of control-line energy delivery at ablation by measuring eP. METHODS AND RESULTS: In vitro tests under constant flow conditions were performed in a 101 bath of physiological saline solution or bovine blood. Endomyocardial preparations of fresh bovine hearts were used. Closed-loop temperature-controlled, irrigated and closed-loop eP-controlled ablations were performed. In vivo animal investigations were performed in six anaesthetized and ventilated pigs. The existence of the eP was established in the tank model and was confirmed in animal investigations. High correlations were found between eP and catheter tip temperature (r=0.87) and between maximum eP and induced lesion size (r=0.85). Also a high correlation (r=0.85, P<0.001) was found between eP and lesion volume. CONCLUSIONS: Control of energy delivery during RF ablation by the measurement of eP is feasible. In comparison with temperature controlled RF ablation, ablation guided by eP-measurement revealed a superior correlation with induced lesion size. Especially during cooled radiofrequency catheter ablation eP is the only parameter for control of energy delivery.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: In about a third of cases of recurrent syncope a diagnosis cannot be established despite extensive cardiovascular and neurologic testing. In patients without underlying heart disease the sensitivity of conventional diagnostic testing is low. CASE REPORT: A 33-year-old male patient underwent implantation of a loop recorder (Reveal) after negative neurological and cardiovascular testing. One month after implantation sinus node arrest could be documented during a presyncope. The patient underwent pacemaker implantation and remains asymptomatic since then. CONCLUSION: In patients with syncope and a negative conventional diagnostic workup the implantable loop recorder is a helpful and cost-effective diagnostic tool.
HISTORY: Some weeks previously a 34-year old athlete, specializing in the triathlon, had 6 syncopes in one day. They had caused abrasions and contusions resulting from the falls. At another hospital paroxysmal atrial fibrillation had been diagnosed and treatment with disopyramide (2 x 200 mg) initiated, but she had about 15 further syncopes within 2 weeks. She was admitted for establishing their cause. INVESTIGATIONS: Initial ECGs and neurological examination failed to provide a diagnosis and she was discharged with an "event recorder". DIAGNOSIS, TREATMENT AND COURSE: Three weeks after discharge she had another syncope. The event recorder was activated by the patient's partner and revealed polymorphous ventricular tachycardia. She underwent extensive invasive cardiological tests, including a right ventricular biopsy, but no abnormality was demonstrated. However, a provocation test with ajmaline produced ST segment elevations in V1 and V2 typical of the syndrome previously described by the Brugadas (right bundle branch block, precordial ST elevations in V1-V3 and sudden cardiac death). A cardioverter-defibrillator was implanted. During the subsequent observation period of 2 month the ICD delivered one countershock, triggered by the onset of polymorphous ventricular tachycardia with syncope. CONCLUSION: In patients with serious ventricular arrhythmias but no diagnostic findings, including a normal resting ECG, a drug provocation test should be performed to exclude a Brugada syndrome.
A variety of electrocardiographic manifestations of dual AV nodal physiology have been reported. The specific subtype dual ventricular response is considered as a very rare phenomenon. We present the case of a 53 year old lady who suffered from paroxysmal regular tachycardias for more than seven years. In the last 6 months the symptomatology of the cardiac arrhythmia changed to more persistent und irregular rhythm disturbances. Treatment with class Ia antiarrhythmic drugs and beta-blocking agents failed. The latter even seemed to worsen her very disturbing palpitations. After examination of the ECG recordings, the diagnosis of dual AV nodal physiology with double ventricular response was made--the lady was referred to our institution for electrophysiological testing and radiofrequency catheter ablation of the slow pathway. An invasive electrophysiological study reconfirmed the diagnosis of a dual AV nodal conduction pattern with irregular double ventricular response. The radiofrequency catheter ablation of the the slow pathway achieved a complete cessation of the double ventricular response. This satisfactory outcome was confirmed by analysis of a postinterventional 24 hour holter recording and an exercise stress test. During a follow-up period of three months, the patient remained free of symptoms and there was no recurrence of dual AV nodal conduction physiology in the surface ECG.
The high incidence of inappropriate therapies due to supraventricular tachycardia remains a major unsolved problem of the implantable cardioverter defibrillator. A new morphology discrimination (MD) algorithm has been introduced to improve specificity of ICD therapy without loss of sensitivity. It was the aim of this study to systematically analyze sensitivity and specificity of the MD criterion in combination with the enhanced detection criteria sudden onset and rate stability in the detection of ventricular and supraventricular tachycardia. After ICD implantation in 259 patients, 787 detected episodes in 74 patients with available stored electrograms were documented during a follow-up period of 359 +/- 214 days. With a nominal programming of the MD algorithm at > or = 60%, sensitivity and specificity for all episodes were 82.6%/77.2%. For sinus tachycardia, atrial fibrillation and atrial flutter the specificities were 80.6%, 69.6% and 75%, respectively. In patients with primarily appropriate MD detection, sensitivity and specificity significantly improved to 95.8%/91.7%. Programming the sudden onset criterion with < 100 ms and the stability criterion with < 50 ms, sensitivity and stability of the combined application of the MD algorithm and sudden onset and MD algorithm and stability were 96.2%/52.2% and 94.4%/63.8%, respectively. The MD criterion in combination with other enhanced detection criteria might significantly improve specificity of tachyarrythmia detection of ICD therapy.
BACKGROUND: For invasive treatment of atrial fibrillation, linear lesions induced with multipolar ablation catheters (MAC) are needed to prevent recurrence. The aim of the study was to compare the efficacy of pulsed versus continuous radiofrequency (RF)-energy delivery using MAC. METHODS: In vitro tests were performed using endomyocardial preparations of fresh pig hearts in a 10-liter-bath of physiologic saline solution (37 degrees C) at constant flow conditions (1.5 l/min). The MAC were placed with a constant pressure of 20 ponds onto the endocardium. The energy (generator: Osypka HAT 200 S) was delivered either pulsed (4 electrodes simultaneously, 5ms duty-cycle) or continuously (each electrode separately). In vivo experiments were performed in 6 anesthetized pigs using fluoroscopic positioning of MAC at 40 different intracardial positions and with similar conditions as in vitro experiments. Lesion volume (LV) was calculated after measuring lesion diameter with a microcaliper. The homogeneity of the lesions (LH) was classified from 1-4; with 1 as highest homogeneity. RESULTS: Pulsed energy delivery produced more homogeneous linear lesions in significantly less time. There was no difference in electrode temperature values (50.2 +/- 0.8 and 51.3 +/- 1.4 degrees C) in vitro and in vivo. In the in vivo experiments, lesion depth and calculated lesion volume were less in both modes of energy delivery but pulsed energy delivery was superior regarding lesion depth and homogeneity. CONCLUSION: With pulsed energy delivery it is possible to create linear lesions of significantly greater homogeneity. Moreover, larger lesions are induced in less time by pulsed energy delivery in vitro and in vivo.