A particle track-repeating algorithm for proton beam dose calculation.

A particle track-repeating algorithm has been developed for proton beam dose calculation for radiotherapy. Monoenergetic protons with 250 MeV kinetic energy were simulated in an infinite water phantom using the GEANT3 Monte Carlo code. The changes in location, angle and energy for every transport step and the energy deposition along the track were recorded for the primary protons and all secondary particles. When calculating dose for a patient with a realistic proton beam, the pre-generated particle tracks were repeated in the patient geometry consisting of air, soft tissue and bone. The medium and density for each dose scoring voxel in the patient geometry were derived from patient CT data. The starting point, at which a proton track was repeated, was determined according to the incident proton energy. Thus, any protons with kinetic energy less than 250 MeV can be simulated. Based on the direction of the incident proton, the tracks were first rotated and for the subsequent steps, the scattering angles were simply repeated for air and soft tissue but adjusted properly based on the scattering power for bone. The particle step lengths were adjusted based on the density for air and soft tissue and also on the stopping powers for bone while keeping the energy deposition unchanged in each step. The difference in nuclear interactions and secondary particle generation between water and these materials was ignored. The algorithm has been validated by comparing the dose distributions in uniform water and layered heterogeneous phantoms with those calculated using the GEANT3 code for 120, 150, 180 and 250 MeV proton beams. The differences between them were within 2%. The new algorithm was about 13 times faster than the GEANT3 Monte Carlo code for a uniform phantom geometry and over 700 times faster for a heterogeneous phantom geometry.

Algorithms↗

Particle in cell simulation of laser-accelerated proton beams for radiation therapy.

In this article we present the results of particle in cell (PIC) simulations of laser plasma interaction for proton acceleration for radiation therapy treatments. We show that under optimal interaction conditions protons can be accelerated up to relativistic energies of 300 MeV by a petawatt laser field. The proton acceleration is due to the dragging Coulomb force arising from charge separation induced by the ponderomotive pressure (light pressure) of high-intensity laser. The proton energy and phase space distribution functions obtained from the PIC simulations are used in the calculations of dose distributions using the GEANT Monte Carlo simulation code. Because of the broad energy and angular spectra of the protons, a compact particle selection and beam collimation system will be needed to generate small beams of polyenergetic protons for intensity modulated proton therapy.

Computer Simulation↗

Comparison of radiosensitization by 41 degrees C hyperthermia during low dose rate irradiation and during pulsed simulated low dose rate irradiation in human glioma cells.

PURPOSE: Long duration mild hyperthermia has been shown to be an effective radiosensitizer when given concurrently with low dose rate irradiation. Pulsed simulated low dose rate (PSLDR) is now being used clinically, and we have set out to determine whether concurrent mild hyperthermia can be an effective radiosensitizer for the PSLDR protocol. MATERIALS AND METHODS: Human glioma cells (U-87MG) were grown to plateau phase and treated in plateau phase in order to minimize cell cycle redistribution during protracted treatments. Low dose rate (LDR) irradiation and 41 degrees C hyperthermia were delivered by having a radium irradiator inside a temperature-controlled incubator. PSLDR was given using a 150 kVp X-ray unit and maintaining the cells at 41 degrees C between irradiations. The duration of irradiation and concurrent heating depended on total dose and extended up to 48 h. RESULTS: When 41 degrees C hyperthermia was given currently with LDR or PSLDR, the thermal enhancement ratios (TER) were about the same if the average dose rate for PSLDR was the same as for LDR. At higher average dose rates for PSLDR the TERs became less. CONCLUSIONS: Our data show that concurrent mild hyperthermia can be an effective sensitizer for PSLDR. This sensitization can be as effective as for LDR if the same average dose rate is used and the TER increases with decreasing dose rate. Thus mild hyperthermia combined with PSLDR may be an effective clinical protocol.