Hydro-jet dissection for laparoscopic nephrectomy: a new technique.

OBJECTIVES: The Hydro-Jet technique has been used to cut various industrial materials. In the medical field, this technique has been successfully used for selective dissection of the parenchyma of organs such as the liver. Recently, this technique was successfully used for laparoscopic cholecystectomy in humans. We developed a new Hydro-Jet probe and a technique of Hydro-Jet dissection during laparoscopic nephrectomy (LN) in a porcine model and compared the results with those of conventional laparoscopy. METHODS: Fourteen pigs underwent unilateral LN using the Hydro-Jet and a conventional LN on the contralateral side. A Muritz 1000 Hydro-Jet generator was used. An adjustable water pressure gauge allowed manual control up to a maximum of 30 atm, and coagulation was applied by way of a bipolar thermoapplicator. The bent end of the probe allowed both blunt dissection and concomitant high-pressure water application. Results were compared with regard to ease of anatomic dissection, complications, and operative time between the two techniques. RESULTS: LN was successful in all animals with no conversion to open surgery. The dissector allowed anatomic planes to be created in a relatively bloodless field, and continuous water flow allowed a clear view for the operator. The high-pressure stream resulted in excellent dissection of adventitial and soft tissue adjacent to vascular structures, with complete preservation of vessels and ureter for selective ligation. The dissection time was shortened (mean 27 minutes for the Hydro-Jet versus 40 minutes for the conventional technique). CONCLUSIONS: To our knowledge, we describe the first report of Hydro-Jet dissection for LN as an alternative to the conventional technique. The improved anatomic dissection may decrease complications. Moreover, shorter operating times were achieved, which may result in cost savings. Further studies in humans are necessary to investigate this technique.

Animals↗

Vesicourethral anastomosis biopsy after radical prostatectomy: predictive value of prostate-specific antigen and pathologic stage.

OBJECTIVES: To assess the role of clinical parameters and pathologic stage in predicting a positive vesicourethral anastomosis (VUA) biopsy in patients with a rising prostate-specific antigen (PSA) level after radical prostatectomy. METHODS: Forty-five patients were referred for a rising PSA level after radical prostatectomy. Transrectal ultrasound evaluation included visualization of the VUA and VUA quadrant biopsies. The rate of positive biopsies (per core and per patient) was correlated with race, PSA level, and the radical prostatectomy pathologic stage. RESULTS: Overall, 53% of patients had a positive biopsy. In multivariate analysis, the dominant independent and synergistic clinical parameters determining positive biopsy rates were a PSA greater than 1 ng/mL at the time of biopsy and the pathologic stage (P = 0.04 and P = 0.02, respectively). Using a PSA cutoff point of 1.0 ng/mL, those patients with organ-confined disease and a PSA of 1.0 ng/mL or less showed no positive cancer cores (low-risk group). Conversely, 89% of patients with extraprostatic extension and a PSA greater than 1.0 ng/mL had a positive biopsy (P <0.01) (high-risk group). Patients with organ-confined disease and a PSA greater than 1.0 ng/mL or extraprostatic extension and a PSA 1.0 ng/mL or less (intermediate-risk group) had a significantly higher chance of having residual cancer than the low-risk group (P <0.025). CONCLUSIONS: The PSA level at the time of biopsy and the pathologic stage of the radical prostatectomy specimen were the strongest determinants of a positive biopsy. A combination of PSA and pathologic stage is useful for decisions regarding VUA biopsy. Patients with organ-confined disease and a PSA of 1.0 ng/mL or less do not appear to benefit from a VUA biopsy, and patients with extraprostatic extension and a PSA greater than 1.0 ng/mL have such a high probability (89%) of local recurrence at the VUA that biopsy may be unnecessary. It appears that VUA biopsy can be restricted to those patients with an intermediate risk (organ-confined disease with PSA greater than 1 ng/mL or extraprostatic extension with a PSA less than 1 ng/mL).

Aged↗

Membrane type 1-matrix metalloproteinase (MT1-MMP) and MMP-2 immunolocalization in human prostate: change in cellular localization associated with high-grade prostatic intraepithelial neoplasia.

Membrane type 1-matrix metalloproteinase (MT1-MMP) is a known activator of latent MMP-2 (pro-MMP-2), and increased MMP-2 expression has been associated with tumor aggressiveness in prostate cancer. However, expression of MT1-MMP in human prostate tissue has not been described. We investigated the expression and immunolocalization of MT1-MMP and MMP-2 in the epithelial components of benign prostate epithelium, high-grade prostatic intraepithelial neoplasia (HGPIN), and prostate cancer. Tissue sections from the peripheral zone of 50 prostates (radical prostatectomy specimens) were chosen based on their containing benign glands, HGPIN, and prostate cancer glands. All 50 sections were immunostained for MT1-MMP and MMP-2 and were evaluated for staining pattern, uniformity, and intensity. Western blotting and gelatin zymography were done to confirm expression of MT1-MMP and activity of MMP-2, respectively. Comparisons were made between benign epithelium, HGPIN, and cancer. In benign glands, basal cells (BCs) uniformly stained intensely for MT1-MMP, whereas secretory cells (SCs) were rarely positive (P < 0.0001). Conversely in HGPIN, SCs showed consistent cytoplasmic staining (P < 0.0001). In cancer cells, staining was heterogeneous and varied from no staining to very intense staining in select glands. MMP-2 in normal tissue stained both BCs and the apical region of SCs, whereas in HGPIN, staining was observed in the SC in a predominantly cytoplasmic pattern. Similar to MT1-MMP, staining in cancer tissue for MMP-2 was heterogeneous; however, there was a significant association between the pattern of MMP-2 and MT1-MMP staining within the epithelial components of the cancer glands in individual specimens (P < 0.001). Finally, MMP-2 and MT1-MMP were confirmed to be expressed in the prostate tissues by gelatin zymography and Western blotting. In conclusion, we found that consistent changes in localization and intracellular distribution of MMP-2 and MT1-MMP were associated with the transition from benign prostate epithelium to HGPIN, suggesting that regulation of these enzymes is altered during the earliest stages of prostate cancer.

Adult↗

Penile implant for intractable priapism associated with sickle cell disease.

Intractable, therapy-resistant priapism in a patient with sickle cell disease is presented. The patient was managed with insertion of an inflatable penile prosthesis. He consequently maintained potency and remains free of priapitic episodes. To our knowledge, immediate penile prosthesis insertion for management of priapism has not been reported. We discuss the indications and advantages of this approach and review the current literature.

Adult↗

Primary adenocarcinoma of the urethra with metastasis to the glans penis: successful treatment with chemotherapy and radiation therapy.

Primary carcinoma of the male urethra accounts for less than 1% of malignancies in males. A 54-year-old man with primary adenocarcinoma of the urethra with metastasis to the glans penis and lymphadenopathy in the right groin was treated successfully by combined chemotherapy (5-fluorouracil and cis-platinum) and external beam radiotherapy (total dose of 75 Gy). Short-term remission using multimodal approach with penile preservation was achieved in the present case.

Adenocarcinoma↗

Inguinal hernia as a rare cause of penile prosthesis malfunction . A report of two cases.

Penile prosthesis malfunction is associated with mechanical failure as well as with infection requiring removal of the prosthesis. We report on the 2 first cases in the literature of inflatable penile prostheses in the presence of inguinal hernia. We advocate early hernia repair in patients with inflatable penile prostheses to avoid malfunction related to hernia.