PubMed Health⌕ Search

Biomedical subjects

B Snyder

Publications and source records attributed to B Snyder.

41 records · Page 3Linked to original sources

Sensitivity of a clinical examination to predict need for radiography in children with ankle injuries: a prospective study.

BACKGROUND: Radiographs are ordered routinely for children with ankle trauma. We assessed the predictive value of a clinical examination to identify a predefined group of low-risk injuries, management of which would not be affected by absence of a radiograph. We aimed to show that no more than 1% of children with low-risk examinations (signs restricted to the distal fibula) would have high-risk fractures (all fractures except avulsion, buckle, and non-displaced Salter-Harris I and II fractures of the distal fibula), and to compare the potential reduction in radiography in children with low-risk examinations with that obtained by application of the Ottawa ankle rules (OAR). METHODS: Standard clinical examinations and subsequent radiographs were prospectively and independently evaluated in two tertiary-care paediatric emergency departments in North America. Eligible participants were healthy children aged 3-16 years with acute ankle injuries. Sample size, negative and positive predictive values, sensitivity, and specificity were calculated. McNemar's test was used to compare differences in the potential reduction in radiographs between the low-risk examination and the OAR. FINDINGS: 607 children were enrolled; 581 (95.7%) received follow-up. None of the 381 children with low-risk examinations had a high-risk fracture (negative predictive value 100% [95% CI 99.2-100]; sensitivity 100% [93.3-100]). Radiographs could be omitted in 62.8% of children with low-risk examinations, compared with only 12.0% reduction obtained by application of the OAR (p<0.0001). INTERPRETATION: A low-risk clinical examination in children with ankle injuries identifies 100% of high-risk diagnoses and may result in greater reduction of radiographic referrals than the OAR.

Adolescent↗

IMRT (intensity modulated radiation therapy): progress in technology and reimbursement.

For a new treatment technology to become widely accepted in today's healthcare environment, the technology must not only be effective but also financially viable. Intensity modulated radiation therapy (IMRT), a technology that enables radiation oncologists to precisely target and attack cancerous tumors with higher doses of radiation using strategically positioned beams while minimizing collateral damage to healthy cells, now meets both criteria. With IMRT, radiation oncologists for the first time have obtained the ability to divide the treatment field covered by each beam angle into hundreds of segments as small as 2.5 mm by 5 mm. Using the adjustable leaves of an MLC to shape the beam and by controlling exposure times, physicians can deliver a different dose to each segment and therefore modulate dose intensity across the entire treatment field. Development of optimal IMRT plans using conventional manual treatment planning methods would take days. To be clinically practical, IMRT required the development of "inverse treatment planning" software. With this software, a radiation oncologist can prescribe the ideal radiation dose for a specific tumor as well as maximum dose limits for surrounding healthy tissue. These numbers are entered into the treatment planning program which then calculates the optimal delivery approach that will best fit the oncologist's requirements. The radiation oncologist then reviews and approves the proposed treatment plan before it is initiated. The most recent advance in IMRT technology offers a "dynamic" mode or "sliding window" technique. In this more rapid delivery method, the beam remains on while the leaves of the collimator continually re-shape and move the beam aperture over the planned treatment area. This creates a moving beam that saturates the tumor volume with the desired radiation dose while leaving the surrounding healthy tissue in a protective shadow created by the leaves of the collimator. In the dynamic mode, an IMRT treatment session generally can be initiated and completed within the traditional 15-minute appointment window for radiation oncology clinics. In addition to being comforting for the patient, this rapid treatment delivery mode satisfies a key financial issue for hospitals and clinics by giving them the ability to handle high patient loads and achieve a more rapid return on their investment in an IMRT system. New IMRT reimbursement codes have been issued under the pass-through provisions of Medicare's Outpatient Prospective Payment System (OPPS), which authorize special or increased reimbursement levels for promising new developments in healthcare technology that previous reimbursement procedures did not address. These pass-through payments are generally applicable for defined periods during a promising new technology's early stage of adoption. In the case of codes G0174 and G0178, the effective period has been left open-ended. While the CMS adoption of these new IMRT reimbursement codes certainly paves the economic road for the diffusion of this technology by flattening out some of the economic obstacles, there are still bumps to overcome. The most obvious one is the investment in hardware and software that may be required. However, the added demands on staff and the cost of training cannot be ignored. IMRT is a treatment process involving FDA-approved medical devices, offering the hope of improved treatment outcomes with fewer complications for patients and higher reimbursement rates for hospital providers. By the end of the year 2001, there will probably be more than 75 hospitals with IMRT capabilities in place.

Centers for Medicare and Medicaid Services, U.S.↗

Nursing perceptions of using physical restraints on hospitalized children.

PURPOSE: To describe the perceptions of pediatric nurses about restraint use in children. METHOD: A descriptive survey using a questionnaire collected data from nurses working in four types of pediatric facilities. Nurses were asked to rate reasons for using restraints and alternatives to restraints on a Likert Scale. Analysis of variance analyzed the nurses' responses according to type of institution and age of the child. An open-ended question asked nurses to list reasons for using restraints. RESULTS: Responses were collected from 60 nurses. There were significant differences in responses according to age of the child and according to the type of hospital. There were no interaction effects. The perceived need for restraints was highest between 1 and 6 years of age. Reasons for using restraints differed among types of facility. CONCLUSIONS: Restraint policies may need to vary according to the type of institution. Intervention and outcome studies are needed regarding the use of physical restraints in children.

Age Factors↗

Institutional policies on the use of physical restraints on children.

Within health care institutions, nursing policies often serve as the gold standard for nursing practice. Policies regarding the use of physical restraints on children are typically not based on any scientific evidence. This article analyzed multiple hospital policies and makes recommendations to better assess whether or not restraints are needed, suggests a list of least to most restrictive devices, identifies interventions for the child in restraints, and offers alternatives to the use of restraints.

Adolescent↗