Optimized standby rate reduces the ventricular rate variability in pacemaker patients with atrial fibrillation.

Patients with chronic atrial fibrillation (AF) and symptomatic bradycardia often receive ventricular-based pacemakers. However, many of these patients continue to have symptoms of palpitations, which may be due to ventricular rate variability. It has previously been shown that continuous ventricular pacing during AF has a stabilizing effect on the ventricular rate. Hence, a study was initiated to determine whether a patient-specific optimal ventricular standby rate that reduces the ventricular rate variability, without over-pacing, could be predicted. A ventricular rate stabilization (VRS) pacing algorithm that increases the pacing rate until instability is reduced below a threshold was developed. The VRS algorithm was utilized to determine a patient-specific standby rate in 15 patients with chronic AF, intact AV nodal conduction, and implanted pacemakers. The computer algorithm controlled a pacemaker programmer to automatically change the pacemaker's ventricular pacing rate via telemetry. Patients were studied for 15 minutes with VRS and for 15 minutes with 50 ppm fixed rate pacing (control). The results were as follows: (1) VRS versus control = P < 0.05; (2) mean ventricular pacing rate (ppm): 77 +/- 13 versus 50 +/- 0; (3) mean ventricular rate (beats/min): 82 +/- 13 versus 79 +/- 12; (4) ventricular rate coefficient of variation (%): 11 +/- 1 versus 22 +/- 5; (5) percent pacing: 75 +/- 8 versus 6 +/- 8; (6) percent of RR intervals less than minimum pacing interval eliminated: 58 +/- 12; (8) regression analysis: mean VRS pacing rate (beats/min) = 0.96 x mean control ventricular rate + 2.3, r2 = 0.85. We concluded that: (1) a moderate increase in the ventricular pacing rate was required to substantially stabilize the ventricular rate; (2) the resulting mean ventricular rate increased marginally; (3) a majority of RR cycles less than each patient's minimum pacing interval were eliminated; and (4) there was a linear relationship between the mean ventricular rate during control and the optimal ventricular pacing rate. Thus, a ventricular pacing rate close to the mean ventricular rate during control consistently reduced the ventricular variability. Although pacing at an increased ventricular standby rate reduces variability at rest, the optimal solution would likely be an adaptive rate algorithm that changes the ventricular standby rate as the mean intrinsic rate varies.

Aged↗

The evolution of the implanted pacemaker's window to the world.

An implanted pacemaker can only communicate with the outside world through its window, i.e., the clinical programmer. Since its inception, the pacemaker has evolved from a non-programmable device to a complex device. Therefore, programming a modern implantable pacemaker could be very challenging for non-experienced or infrequent users. Various programmer-based automatic functions have been developed to reduce programming time and complexity and to obtain accurate measurements. With increasing interests in the telecommunications and information exchange, these programmer-based automatic functions are pushing forward a future vision that automatic pacemaker follow-up procedures via telecommunications are possible for patients located in any corner of the globe.

Biomedical Engineering↗

A rate responsive pacemaker that physiologically reduces pacing rates at rest.

Current rate responsive pacemakers incorporate sensors such as minute ventilation (MV) for adapting to changing patient conditions during exercise and periods of exertion. However, for sleep and/or rest periods, the only pacemakers currently on the market that slow the pacing rate utilize an internal timer to determine a decrease in pacing rate. It would be advantageous if the pacing rate could be automatically lowered during periods of sleep or rest. This study utilized a rate responsive sensor, MV, to track the patient's sleeping and resting periods and to decrease the pacing rate at such times. A total of eight patients implanted with Sentri 1210 single chamber MV sensor pacemakers were studied. A sleep rate (SR) of 45 beats/min was selected. A sleep rate response function, which indicated the relationship between changes in MV and corresponding heart rate, was initially set at a value of 16 and continually and automatically updated in a 3-month study. Adaptation was based on the premise that 3 hours per day should be spent at the SR. The average decrease in pacing rates from onset to 3 month for the eight patients was 12.4% +/- 5.3%. Correspondingly, the histograms of the lowest datalog histogram (40-59 beats/min) increased from 0% to 15.4% +/- 0.9% of paced beats. Correlation between the patients' 24-hour diary and Holter recordings showed that the pacing rates during sleep were consistently lower than when the patients were awake and active. This was also the case with a patient whose nocturnal and daily routine was intentionally altered.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Effects of stress and beta 1 blockade on the ventricular depolarization gradient of the rate modulating pacemaker.

Prism-CLR is a closed loop, rate modulating pacemaker that uses ventricular depolarization gradient (Gd) to continuously adjust heart rate. Heart rate response to a formal mental stress protocol, esmolol (500 mcg/kg bolus, 75-125 mcg/kg/min infusion), and mental stress during esmolol infusion were studied in six patients to investigate if Gd and paced heart rate response are under direct beta-adrenergic control. Paced heart rates increased in response to mental stress in a physiological manner (P less than 0.001). Response to esmolol infusion was paradoxical, with increased paced heart rates during esmolol bolus and infusion (P less than 0.05). There was no significant alteration in either systolic or diastolic blood pressure during mental stress or esmolol infusion (P greater than 0.05). Paradoxical increase in paced heart rates during esmolol administration suggests a primary or secondary effect of esmolol to decrease the ventricular depolarization gradient. This hypothesis was supported in four dog studies in which direct Gd measurements were made during esmolol infusion. Mental stress during esmolol infusion resulted in significantly increased paced heart rates (esmolol effect) with blunted changes in heart rate in response to the mental stress. The results of this study suggest that the physiological rate response during mental stress is attributable to sympathetic autonomic response.

Adrenergic beta-Antagonists↗

Directional differences in excitability and margin of safety for propagation in sheep ventricular epicardial muscle.

Computer simulations and isolated tissue experiments were used to characterize the relation between excitability and margin of safety for propagation in anisotropic ventricular myocardium. Longitudinal, uniform transverse, and nonuniform transverse tissue directions were modeled in a one-dimensional Beeler-Reuter based cable. Stimulation threshold was smallest in the nonuniform transverse direction. The safety factor for propagation was determined in the model as the total axial charge that was available for depolarizing downstream tissue divided by the threshold charge that was just sufficient for continued propagation and was largest in the longitudinal direction. The strength-interval plot for the junction between simulated longitudinal and nonuniform transverse directions identified a range of stimulus strengths and intervals that resulted in nonuniform transverse but not longitudinal propagation. When high values of transverse resistance were used, higher stimulus strengths during premature stimulation resulted in longitudinal but not nonuniform transverse propagation. The experimental strength interval plots from 17 L-shaped preparations of isolated sheep epicardial muscles had similar characteristics. In nine additional L-shaped tissue experiments, changing extracellular K+ concentrations from 4 to 20 mM resulted in progressive membrane depolarization and conduction impairment in both directions. However, in eight of nine experiments, complete block occurred first in the transverse direction. In one experiment, block was simultaneous in both directions. We conclude that, under normal conditions, threshold requirements for active propagation are lower for transverse than for longitudinal propagation. In addition, when active membrane properties are impaired, the safety factor for propagation is larger in the direction along the longitudinal axis of the cells.

Adult↗