PubMed Health⌕ Search

Biomedical subjects

B Tiep

Publications and source records attributed to B Tiep.

3 recordsLinked to original sources

Noninvasive positive-pressure ventilation in chronic obstructive pulmonary disease.

Interest in noninvasive positive-pressure ventilation both as an alternative to intubation and mechanical ventilation and as a unique therapy has grown over recent years. Clinical and patient acceptance is highest in neuromuscular deficits, but supporting evidence for its use in chronic obstructive pulmonary disease is highly dependent on the application. This review considers the clinical implementation of noninvasive positive-pressure ventilation in acute respiratory failure, as a postextubation weaning alternative, in stable severe hypercapnic chronic obstructive pulmonary disease, in overlap syndrome, and for nocturnal oxygen desaturation. Some applications are well supported, leading to a cautious recommendation for its utilizatip4, whereas for others evidence is starkly conflicting. The clinical efficacy of noninvasive positive-pressure ventilation is vastly dependent on equipment, equipment-patient interface, pressure settings, physician's bedside manner, and experience of the center. Interpretation of the studies must take into account the foregoing factors along with the various ventilatory techniques and differing primary outcome measures. Generalizations can be made regarding indications and contraindications, but this is an area rife with exceptions. The subtle message from the clinical studies describes the importance of the clinical art applied from the palette of science and technology.

Acute Disease↗

Portable oxygen therapy with oxygen conserving devices and methodologies.

Oxygen therapy for the end-stage COPD patient should include a portable component. Accordingly, any system should be small and lightweight in order to enable the chronically debilitated patient to be as active and mobile as possible. Standard continuous flow oxygen via nasal cannulae is reliable and effective but it is also very wasteful. As a result, oxygen conserving methodologies have emerged to improve the efficiency of oxygen delivery and have served to lighten the load for these patients. These devices include: reservoir cannulas, transtracheal catheters and demand pulsing delivery devices. They provide oxygen savings from 2:1 to 7:1 over continuous flow delivery. In addition to rendering the newer oxygen systems more portable, they can also reduce the cost of oxygen and its associated service. As patient requirements are highly individual, the wide choice of available methodologies permits the clinician to prescribe the system that best suits the needs of the patient.

Aged↗

Evaluation of the pendant oxygen-conserving nasal cannula during exercise.

There is much recent evidence that patients with chronic pulmonary disease who are hypoxemic benefit from continuous therapy with oxygen. These benefits include reduction in symptoms of cor pulmonale, reduction in mortality, and improvement in quality of life. Oxygen therapy is very expensive, and steady-flow delivery of oxygen is wasteful, since almost the entire benefit of the oxygen presented to the patient occurs at the very beginning of inspiration. We previously described a conserver nasal cannula (CNC) which stores oxygen during exhalation for delivery during subsequent inspirations. The CNC achieves adequate arterial oxygen saturation (SaO2) at one fourth to one half of the flow in liters of steady-flow oxygen delivery. Because some patients found the mustache configuration objectionable, a pendant nasal cannula (PNC) was designed, displacing the reservoir off of the face and onto the anterior wall of the chest. While both cannulas require some breathing by nose to function, the PNC is more esthetically acceptable. No studies with exercise have been reported using the PNC. We evaluated the PNC during treadmill exercise in ten subjects with chronic obstructive pulmonary disease and hypoxemia on exercise. We compared the PNC with steady-flow oxygen during steady level treadmill walking sufficient to cause oxygen desaturation while breathing room air at oxygen presentations of 0.5 through 3.0 L/min. At comparable workloads the SaO2 achieved by PNC required one third of the oxygen flow required by steady-flow oxygen to achieve an equivalent SaO2. These differences were statistically significant (p less than 0.01). We conclude that the PNC provides effective delivery of oxygen during exercise, as well as at rest, while minimizing oxygen flow rate and thus substantially reducing the economic burden normally associated with supplemental oxygen delivery.

Aged↗