The engineering of an interventional MRI with a movable 1.5 Tesla magnet.

The engineering of a novel intra-operative MRI system is described. A movable, 1.5 Tesla MRI magnet was placed in a neurosurgical operating room without affecting established neurosurgical procedure. The system allows fast, high-quality MR intra-operative imaging of the brain and spine without the necessity of patient transportation. A neuro-navigational device capable of displaying and updating spatially referenced MR images in the operating room was integrated with the MRI system. Over 100 procedures have been carried out with this system without limiting surgical access and without compromising traditional neurosurgical, nursing or anesthetic techniques. J. Magn. Reson. Imaging 2001;13:78-86.

Brain↗

Spin-echo versus gradient-echo fMRI with short echo times.

Blood-oxygen level dependent signal changes in the visual cortex were investigated as a function of echo time with spin-echo and gradient-echo EPI at 1.5 T and 3 T. The linear relationship between the fractional signal change and the echo time was apparent in all cases. Relaxation rate changes determined from the slope of this linear relation agree with published values, intercept values extrapolated to an echo time of zero, however, were 0.66% to 1.0% with spin-echo EPI, and 0.11% to 0.35% with gradient-echo EPI. Spin-echo and gradient-echo EPI can therefore yield similar signal changes at sufficiently short echo times.

Echo-Planar Imaging↗

Characterization of contrast changes in functional MRI of the human spinal cord at 1.5 T.

Contrast changes observed in functional magnetic resonance imaging in the human spinal cord were investigated with both motor and sensory tasks over a range of echo times. Data were acquired using a single-shot fast spin-echo sequence at 1.5 Tesla. Data were analyzed with two different correlation thresholds and the effects of altering the order of repeated experiments was also investigated. Plots of the fractional signal change as a function of echo time yielded linear functions with slopes corresponding to relaxation rate changes of -0.30 sec(-1) with sensory stimulation and approximately -0.50 sec(-1) with a motor task. However, the fractional signal change extrapolated to an echo time of zero was significantly greater than zero in each case and was roughly 2.5%. This suggests that in addition to the BOLD effect there is a baseline signal change which occurs concomitant to neuronal activation in the spinal cord.

Adult↗

Probe with chest shielding for improved breast MRI.

The design and construction of an RF coil system for use in MR breast imaging is described. The two-ring, tuned Helmholtz coil, with its axis perpendicular to the chest, surrounds a single pendant breast and is coupled both internally and to the MRI transmitter/receiver by mutual induction. The addition of two symmetrical RF shields minimizes losses in the chest and significantly improves performance. Images obtained from eight healthy volunteers showed that the coil permitted imaging of breasts of diverse size with an in-plane resolution of 0.27 x 0.27 mm and a slice thickness of less than 2 mm at a field strength of 3 T as well as 1.5 T. The use of shields with surface coils in general is advocated as a method for improving signal-to-noise ratio. Magn Reson Med 43:917-920, 2000.

Breast Diseases↗

Analysis of ovariectomy and estrogen effects on body composition in rats by X-ray and magnetic resonance imaging techniques.

Resistance of bone to fracture--bone strength--has been shown to depend on both the amount of bone and its architectural spatial organization. In vivo magnetic resonance (MR) techniques have the capability of imaging bone tissue, including the trabecular microarchitecture and the marrow composition. We have applied in vivo and ex vivo MR methods to the tibia in an ovariectomized rat model of osteoporosis. Specifically, in vivo high-resolution three-dimensional MR imaging and localized MRS were facilitated by specialized coils and high field magnets, resulting in enhanced sensitivity of detection. As a result, in vivo and ex vivo differences in marrow composition were found between sham-ovariectomized, ovariectomized, and ovariectomized animals treated with 17-beta-estradiol. Estrogen effects were detected in vivo 7 days after surgery (3 days into treatment) as a decrease in the tibial fat signal level. The in vivo effects of ovariectomy were observed 56 days after surgery as an increase in MR image fat signal level and spectral fat/water ratio in the proximal tibia. Ex vivo measurements of tibial marrow water signal discriminated clearly between the sham and ovariectomized groups and showed increased individual variations in the treatment group. Imaging further showed that the highest fat content is observed in the epiphysis. Computed tomography confirmed ovariectomy-induced loss of bone in the proximal tibial metaphysis compared with the sham group. This loss of cancellous bone with ovariectomy is consistent with the MR observations of increases in both fat and water in the metaphysis. These data showed that MR techniques complement X-ray techniques in the bone, water, and fat compositional analysis of the appendicular skeleton in response to ovariectomy and pharmacological treatment.

Adipose Tissue↗

MR spectroscopy using multi-ring surface coils.

A spatially uniform B(1)-field is preferred for MR imaging and spectroscopy. Unfortunately, volume coils are sometimes unavailable, or do not provide adequate RF power or SNR for some applications. In quantitative MRS, mean metabolite concentration cannot be evaluated when the coil response is nonuniform, unless an assumption is made concerning the metabolite spatial distribution. It is well known that standard single-loop surface coils, although offering high SNR characteristics, have poor B(1) homogeneity. New multi-ring surface coils are proposed which produce a locally uniform B(1) field, with sensitivity and power requirements comparable to those of standard surface coils. MR spectroscopy using two and three-ring versions of this "local volume coil" result in spatial localization essentially identical to that obtained with a volume coil but with much improved RF power and SNR characteristics. When compared to standard surface coils, the multi-ring coil offers much improved water suppression and localization, as well as reduced outer voxel contamination, with only a small loss in SNR and moderate increase in SAR. In summary, the multi-ring coil operates midway between the volume coil and the standard surface coil, retaining the most advantageous properties of both. Magn Reson Med 42:655-664, 1999. Published 1999 Wiley-Liss, Inc.

Humans↗

A mobile high-field magnetic resonance system for neurosurgery.

OBJECT: The authors' goal was to place a mobile, 1.5-tesla magnetic resonance (MR) imaging system into a neurosurgical operating room without adversely affecting established neurosurgical management. The system would help to plan accurate surgical corridors, confirm the accomplishment of operative objectives, and detect acute complications such as hemorrhage or ischemia. METHODS: The authors used an actively shielded 1.5-tesla magnet, together with 15 mtesla/m gradients, MR console computers, gradient amplifiers, a titanium, hydraulic-controlled operating table, and a radiofrequency coil that can be disassembled. The magnet is moved to and from the surgical field by using overhead crane technology. To date, the system has provided unfettered access in 46 neurosurgical patients. In all patients, high-definition T1- and/or T2-weighted images were rapidly and reproducibly acquired at various stages of the surgical procedures. Eleven patients underwent craniotomy that was optimized after preincision imaging. In four patients who harbored subtotally resected tumor, intraoperative MR imaging aided the surgeon in removing the remaining tumor. Interestingly, the intraoperative administration of gadolinium demonstrated a dynamic expansion of enhancement beyond the preoperative contrast contour in patients with malignant glioma. These zones of new enhancement proved, on examination of biopsy samples, to be tumor. CONCLUSIONS: The authors have demonstrated that high-quality MR images can be obtained in the operating room within reasonable time constraints. Procedures can be conducted without compromising or altering traditional neurosurgical, nursing, or anesthetic techniques. It is feasible that within the next decade intraoperative MR imaging may become the standard of care in neurosurgery.

Adult↗

Dual surface coil with high-B1 homogeneity for deep organ MR imaging.

The theory and construction of a dual surface coil which provides good B1 homogeneity and sensitivity in a defined volume of interest is described. The probe comprises two coaxial rings, of different diameters and in different planes, which carry opposing currents of different values. Current in the second ring compensates for the roll-off of the B1 field associated with a single surface coil. Coupling between the rings and a third matching ring is by mutual inductance only. A comparison to a traditional surface coil with practical application to pig brain imaging at a field strength of 7 Tesla is shown.

Animals↗

Double EPI sequence with 180 degrees RF pulses.

Rapid imaging can be performed in the magnetic field of low homogeneity using 180 degrees RF pulses instead of gradient reversals to form a series of differently phase-encoded echoes. A modified version of pi-pulsed EPI which samples the data in two complementary shots was designed. Its advantage for objects of short T2 is illustrated by phantom images.

Fourier Analysis↗