PubMed Health⌕ Search

Biomedical subjects

B Tombach

Publications and source records attributed to B Tombach.

32 records · Page 2Linked to original sources

Does a higher concentration of gadolinium chelates improve first-pass cardiac signal changes?

The purpose of this study was to evaluate first-pass cardiac signal changes with a higher concentrated gadolinium-chelate (gadobutrol) and its influence on bolus geometry. Phantom studies and in vivo first-pass cardiac studies were performed in rabbits (n = 8 experiments) under general anesthesia at 1.0 T using an ultrafast T1-weighted Turbo-fast low-angle shot (FLASH) sequence (TR/TE 4.7/1. 6 msec, alpha = 90 degrees ) with a time resolution of 870 msec. Gadobutrol was injected as an intravenous bolus at two concentrations (0.5 and 1.0 mol Gd/L) and five doses (0.3, 0.15, 0.1, 0.055, and 0.03 mmol Gd/kg bw). The blood-pool gadolinium compound gadopentetate dimeglumine-polylysine (0.15, 0.075, 0.05, and 0.015 mmol Gd/kg bw, 0.5 mol Gd/L) and the standard extracellular gadopentetate dimeglumine (0.1 and 0.05 mmol Gd/kg bw, 0.5 mol Gd/L) served as reference agents. Cardiac signal changes were calculated from serial signal intensity measurements. Maximum signal intensity changes and best peak profiles during first pass of the right and left ventricle were observed with a dose of 0.03 mmol Gd/kg bw gadobutrol using T1-weighted Turbo-FLASH. At the low application volumes used, the higher concentration of 1.0 mol Gd/L gadobutrol did not increase the degree of signal intensity changes or sharpen the bolus profile. First-pass cardiac signal changes using T1-weighted Turbo-FLASH with the new extracellular contrast agent gadobutrol are best observed at a dose of 0.03 mmol Gd/kg bw. There is no advantage to the concentrated formulation (1 mol Gd/L gadobutrol) when using small injection volumes. J. Magn. Reson. Imaging 1999;10:806-812.

Animals↗

Clearance of iopromide during haemodialysis with high- and low-flux membranes.

PURPOSE: The present clinical trial addressed the clearance of the contrast medium iopromide, a middle-sized molecule, during dialysis with high- and low-flux membranes. MATERIAL AND METHODS: Twenty chronic haemodialysis patients without residual renal function were dialysed either with low-flux haemophan or high-flux polyamide directly after application of the contrast medium. Iodine concentrations were determined by radiofluorescence methods. RESULTS: Plasma concentrations of iodine before dialysis ranged between 1.1 and 3.9 mg/ml. The mean clearance rates for both membranes were comparable (110+/-1.4 ml/min high-flux and 108+/-1.9 ml/min low-flux), the sieving-coefficient was 0.83 for both membranes. After three hours of dialysis, 58% (high-flux) and 62% (low-flux) of iopromide was removed, half time of elimination was reached after 140+/-16 min (high-flux) and 122+/-11 min (low-flux). CONCLUSION: Our results demonstrated that elimination of iopromide is not dependent on the pore size of the membrane during dialysis. Due to higher blood flow rate, we found a higher elimination rate and a reduced half-time of elimination than prior investigations.

Contrast Media↗

Hepatic MRI with SPIO: detection and characterization of focal liver lesions.

A variety of parenterally administered iron oxides have been developed for contrast-enhanced MRI of the liver. Two different classes of iron oxides are currently clinically approved or in phase 3 trials: superparamagnetic iron oxides (SPIO) with a high R2/R1 relaxivity ratio and short blood half-life (AMI-25 and SH U 555 A), and ultrasmall paramagnetic iron oxides (USPIO) with a lower R2/R1 relaxivity ratio and longer blood half-life (AMI-227). All iron oxides significantly increase tumor-to-liver contrast and allow detection of more lesions than unenhanced MRI on T2-weighted images at a field strength of 0.2-1.5 T. Malignant lesions without phagocytic cells exhibit constant signal on T2-weighted accumulation phase images with all three iron oxides. All iron oxides cause a signal decrease of benign lesions with either phagocytic cells or a significant blood pool on T2-weighted accumulation phase images. The signal decrease of benign lesions is proportional to the Kupffer cell activity or tumor vascularity and is useful for lesion characterization. Another enhancement feature for the differentiation of benign from malignant lesions is ring enhancement of malignant lesions (metastases) on T1-weighted enhanced images either during the perfusion phase with SH U 555 A or during the accumulation phase with AMI-227, which is attributed to the blood pool effects of the compounds. Differentiation of lesions and vessels is easier on enhanced images with angiographic effects than on unenhanced images. Iron oxides improve the quality of two-dimensional MR angiography techniques of the portal venous system by decreasing background signal (liver tissue with all iron oxides) and increasing intravascular signal (AMI-227). The use of iron oxides for hepatic MRI provides an alternative to the existing multistep diagnosis with CT, CT portography, MRI and biopsy.

Contrast Media↗

[T1-weighted dynamic MRI with new superparamagnetic iron oxide particles (Resovist): results of a phantom study as well as 25 patients].

PURPOSE: Evaluation of the diagnostic usefulness of the T1-effect of Resovist (SPIO) for dynamic MRI of the liver. METHOD: In-vitro measurements of a dilution series with T1-weighted FLASH and SE sequences and investigation of 25 patients with known focal liver lesions with a T2-weighted TSE sequence and a dynamic T1-FLASH sequence. RESULTS: T1-weighted MRI with Resovist in vitro showed a positive enhancement at low concentrations and a negative enhancement at higher concentrations. In-vivo T1-weighted dynamic MRI liver parenchyma demonstrated a positive enhancement 30 s post contrast, followed by a continuous slope of signal intensity and a negative enhancement (> or = 60 s). Spleen, portal venous vessels and haemangiomas showed an early increase in signal intensity followed by a decreasing positive enhancement, but without negative enhancement. During the perfusion phase metastases showed a small but not significant increase in signal intensity. In 80% a positive ring enhancement could be observed around metastases. CONCLUSION: Resovist exhibits a diagnostically useful T1-effect. An evaluation of the perfusion of focal liver lesions during the distribution phase is possible with dynamic T1-weighted MRI. This approach may further improve characterisation of focal liver lesions.

Adult↗

Enhancement characteristics of liver metastases, hepatocellular carcinomas, and hemangiomas with Gd-EOB-DTPA: preliminary results with dynamic MR imaging.

Our objective was to study Gd-EOB-DTPA for the characterization of focal liver lesions by means of dynamic MR imaging. A double-blind and randomized dose-ranging phase-2 clinical trial was performed in 31 patients (liver metastases n = 23, hepatocellular carcinoma n = 4, and hemangioma n = 4) at a field strength of 1.0 Tesla. Gd-EOB-DTPA (Schering AG, Berlin, Germany) was administered as an IV bolus (12.5, 25, or 50 micromol/kg body weight) with dynamic T1-weighted MRI during the distribution and cellular uptake of the contrast agent at multiple time points up to 45 min post contrast. Dynamic changes in tumor signal intensity, tumor-liver contrast, enhancement patterns, side effects, and adverse events were evaluated. Monitoring of vital signs revealed no significant changes during bolus injection of Gd-EOB-DTPA. Liver metastases demonstrated an inhomogeneous uptake of Gd-EOB-DTPA during the distribution phase with a washout effect on delayed images > 3 min and highest tumor-liver contrast 20 and 45 min post contrast. Hepatocellular carcinomas showed prolonged enhancement as compared with metastases and hemangiomas. Hemangiomas exhibited an early peripheral-nodular enhancement with subsequent partial or complete filling, persisting enhancement < 10 min following injection of Gd-EOB-DTPA, and delayed washout as compared with liver metastases. Initial clinical experience suggests that Gd-EOB-DTPA as a bolus injectable hepatobiliary MR contrast agent may offer useful features for the characterization of focal liver lesions.

Carcinoma, Hepatocellular↗

[New MR contrast media in liver diagnosis. Initial clinical results with hepatobiliary Eovist (gadolinium-EOB-DTPA) and RES-specific Resovist (SH U 555 A)].

The purpose of this work is to describe our initial clinical experience (in 66 patients) with Resovist and Eovist, two new liver-specific MR contrast agents. We focus our report on safety aspects, dose finding, and optimization and technical parameters. Both contrast agents were well tolerated and improved the detectability of focal liver lesions. With Resovist, postcontrast MRI may be started as early as 10 min following injection. The dose of 8 mumol Fe/kg bodyweight was sufficient to achieve diagnostic tumor-liver contrast levels. Since Eovist can also be administered as a bolus, dynamic enhancement patterns may be studied for tumor characterization as well. Breath-hold T1-weighted FLASH images were superior to other T1-weighted techniques with and without fat saturation.

Contrast Media↗

Phase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence.

PURPOSE: To investigate the efficacy of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) in the detection of focal liver lesions with respect to dose, side effects, and pulse sequence. MATERIALS AND METHODS: A randomized double-blinded trial was performed in 33 patients with focal solid liver lesions. A bolus of Gd-EOB-DTPA, a liver-specific contrast agent, was intravenously administered at three different doses (12.5, 25, and 50 mumol per kilogram of body weight). Magnetic resonance imaging with different T1-weighted techniques was performed 20 and 45 minutes after administration of Gd-EOB-DTPA. Changes in liver signal intensity, lesion-liver contrast-to-noise ration (C/N), detectable liver lesions, side effects, and adverse events were evaluated. RESULTS: Gd-EOB-DTPA significantly (P < .05) increased liver signal intensity and lesion-liver C/N within the dose range tested. Lesion detection was improved 20 and 45 minutes after administration of Gd-EOB-DTPA. A dose of 12.5 mumol was sufficient for the detection of focal liver lesions, and the breath-hold, T1-weighted, fast low-angle shot pulse sequence was the most useful. No significant changes in vital signs, clinical laboratory test results, and urinalysis were observed. CONCLUSION: Gd-EOB-DTPA is an efficient, diagnostically useful, and safe contrast agent.

Contrast Media↗

Clinical results with Resovist: a phase 2 clinical trial.

PURPOSE: To investigate the superparamagnetic iron oxide (Resovist) designed for contrast material-enhanced magnetic resonance imaging of the liver. MATERIALS AND METHODS: A phase 2 trial was performed in 33 patients with no more than five known focal solid liver lesions. Resovist was administered intravenously at doses of 4, 8, and 16 mumol of iron per kilogram of body weight. Postcontrast 1.0-T imaging was started 30 minutes after injection. RESULTS: Resovist significantly (P < or = .05) decreased liver signal intensity and increased lesion-to-liver contrast-to-noise ratio (C/N) and the number of detectable liver lesions: fast spin-echo (SE) (echo time, 90 msec) precontrast C/N, 11.7 +/- 7.9 [standard deviation]; postcontrast [8-mumol Fe/Kg] C/N, 29.2 +/- 14.2). The dose of 8 mumol Fe/kg was sufficient for the detection of focal liver lesions, and T2-weighted fast SE with an echo time of 90 msec was the overall best pulse sequence. CONCLUSION: Resovist is a safe contrast agent, and a dose of 8 mumol Fe/kg is sufficient to enhance detection of focal liver lesions at T2-weighted fast SE MR imaging.

Contrast Media↗

[New super-paramagnetic iron particles for MRI. Phase II study of malignant liver tumors].

The clinical tolerability and diagnostic value of Resovist as a new superparamagnetic iron oxide contrast medium was studied in 30 patients with malignant focal liver lesions (28 metastases, 2 HCC) within a phase II multicenter study. Magnetic resonance imaging (MRI) was performed at 1.0 Tesla with T1-weighted FLASH- and T2-weighted spin echo sequences before and following intravenous injection of Resovist at three different dose groups (4, 8 and 16 mumol Fe/kg). Liver signal intensity was significantly reduced on post-contrast images, while malignant focal liver lesions showed no signal changes. Resovist improved tumor liver contrast and lesion-conspicuity, especially for lesions smaller than 1 cm. The dose of 8 mumol Fe/kg was sufficient to achieve diagnostic tumor-liver contrast. Compared to images directly after injection, the number of detected lesions did not improve until 70 min later. There were no significant changes in vital signs (heart rate, blood pressure) or laboratory values until 72 h post-injection.

Adult↗

[Rapid spin echo sequences for detection and characterization of focal liver lesions. Use of fast T2-weighted spin echo with fat suppression and fast spin echo with combined gradient echo (GRASE)].

The purpose of this study was to assess the value of fast-spin-echo (FSE) sequences without and with fat suppression as well as gradient-and-spin-echo (GRASE) sequences for the detection and subsequent characterization of focal liver lesions. A total of 51 consecutive patients with clinically suspected focal liver lesions were studied. FSE without fat suppression proved to be valuable for the detection (TE 90 ms) and characterization (TE 158 ms) of focal liver lesions. Fat suppression did not improve the performance of FSE. GRASE sequences with multiple excitations were clinically superior to the faster single-shot approach.

Carcinoma, Hepatocellular↗

[Echo-planar imaging (EPI) of the abdomen].

The time resolution of echoplanar imaging (EPI) allows the acquisition of images < or = 100 ms, thus eliminating motion-related artifacts of the abdomen. Physical limitations are restrictions in signal-to-noise ratio and spatial resolution. Breath-held acquisitions are recommended to avoid spatial misregistrations and to ensure a defined slice position. Clinical studies have demonstrated the usefulness of EPI for the detection and characterization of focal liver lesions. The development of clinical strategies of EPI for abdominal imaging requires the administration of gastrointestinal contrast agents as in computed tomography. Current clinically approved CT contrast agents appear to be applicable for abdominal EPI because of their long relaxation times.

Abdominal Neoplasms↗

Purification of human placental prostaglandin 15-hydroxydehydrogenase.

The NAD(+)-linked prostaglandin 15-hydroxydehydrogenase, which is responsible for the physiological inactivation of prostaglandins by catalysing the first step in the catabolism, was isolated and purified 995-fold from human placenta. The introduction of two new chromatographic steps in the purification procedure is responsible for an achieved specific activity of 1791 mU/mg. The molecular mass of the enzyme, as estimated by fast protein liquid chromatography, was 24,500 dalton. Sodium dodecyl sulphate discontinuous gel electrophoresis of the denatured enzyme revealed a molecular mass of 24,000 dalton. These data suggest that the enzyme consists of a single polypeptide chain.

Chromatography↗

Influence of dialysis procedure, membrane surface and membrane material on iopromide elimination in patients with reduced kidney function.

Haemodialysis for the elimination of contrast medium in patients with advanced renal failure is a common procedure. Even though sufficient elimination with the use of regular low-flux membranes is documented, large differences in results have been reported in prior investigations. We, therefore, compared Cuprophan and polysulfone dialysers with different surface areas to haemofiltration with different amounts of substitution fluid in 40 patients with compromised renal function after coronary angiography. Plasma iodine concentrations were measured by fluorescent excitation analysis. At constant blood flow rates of 200 ml/min, Cuprophan membranes with 1. 3 m(2) surface area had a clearance rate of 87 ml/min, whereas polysulfone membranes of comparable size displayed a significantly higher clearance rate of 147 ml/min. Polysulfone membranes with 1.8 m(2) surface area showed a small but insignificant increase in the iodine clearance (162 ml/min), while Cuprophan membranes displayed an increase in clearance rates (121 ml/min). Additional ultrafiltration led to a further increase in the plasma clearance of both membranes and reduced urinary iodine excretion. Haemofiltration was comparable to haemodialysis in terms of efficacy and thus represents an alternative method. Clearance of iopromide during haemodialysis with polysulfone membranes is higher than with Cuprophan membranes. Elimination rates can be further increased by additional ultrafiltration. Haemofiltration is comparable to haemodialysis regarding contrast medium elimination.

Biocompatible Materials↗