PubMed Health⌕ Search

Biomedical subjects

B Tuohy

Publications and source records attributed to B Tuohy.

2 recordsLinked to original sources

Quality assurance programme applied to mobile C-arm fluoroscopy systems.

The importance of quality assurance (QA) of X-ray equipment in diagnostic imaging departments is well recognised. However, practically no attention has been paid in the literature to the application of QA programmes to mobile C-arm fluoroscopy systems. This equipment is sometimes omitted from these programmes because it is often "off-site" from the main radiological facility and suitable QA protocols are unavailable. The need for QA can be substantiated by the fact that these systems are finding greater clinical use in orthopaedic, vascular and cardiac applications. Hence, there is a growing awareness among users for the need of good image quality and low patient radiation dose. In view of this, the objective of this study was to review the existing literature, design a suitable QA protocol for this equipment and use it to survey 10 C-arms in clinical use. The protocol was designed to address mechanical and electrical safety in addition to radiation safety and image quality. Results indicate substantial performance differences between systems with significant variations in input air kerma rate to the image receptor. The authors believe that such a protocol is necessary with a view to establishing optimal performance levels and assist in the development of suitable "write-off" criteria for such systems.

Equipment Safety↗

The fast flush test: evaluation in radial artery catheter-manometer systems.

The 'fast flush test' is commonly used to determine the dynamic response of catheter-manometer systems in vivo. We compared the fast flush test with an established bench top test in vitro. The results of the two tests were compared in fifteen underdamped radical artery catheter-manometer systems. There were significant differences between the results, (P less than 0.001 for both resonant frequency and damping factor), and the variance of estimates within measurement systems was significantly greater in the case of the fast flush test (P less than 0.05 and P less than 0.005 for resonant frequency and damping factor respectively). Nevertheless, the differences between the tests were small by comparison with the errors associated with either test; in addition there was a significant linear correlation between the results of the two tests (r = 0.91, P less than 0.001 and r = 0.85, P less than 0.001 for resonant frequency and damping factor respectively). In the in vitro situation, therefore, the fast flush test provides a crude estimate of the dynamic parameters of underdamped catheter-manometer systems.

Arteries↗