PubMed Health⌕ Search

Biomedical subjects

B V Sarada

Publications and source records attributed to B V Sarada.

9 recordsLinked to original sources

Gradient liquid chromatography of leucine-enkephalin peptide and its metabolites with electrochemical detection using highly boron-doped diamond electrode.

Boron-doped diamond thin film (BDD) electrodes have been used to study the oxidation reactions and to detect leucine-enkephalinamide (LEA) and its metabolites, tyrosine (T), tyrosyl-alanine (TA), tyrosyl-alanine-glycine (TAG) and leucine-enkephalin (LE) using cyclic voltammetry (CV), flow-injection analysis (FIA), and gradient liquid chromatography (LC) with amperometric detection. At diamond electrodes, well-defined and highly reproducible cyclic voltammograms were obtained with signal-to-background (S/B) ratios 5-10 times higher than those observed for glassy carbon (GC) electrodes. The analytical peaks of LC for LEA and its metabolites were well resolved. No deactivation of BDD electrodes was found after several experiments with standard as well as plasma samples, indicating high stability of the electrode. Calibration curves were linear over a wide range from 0.06 to 30 microM with regression coefficients of 0.999 for all compounds. The limits of detection obtained based on a signal-to-noise ratio of 3:1 were 3, 2.2, 2.7, 20 and 11 nM for T, TA, TAG, LE and LEA, respectively. These values were at least one order lower than those obtained at GC electrodes, which has given limits of detection of 22.88, 20.64, 89.57, 116.04 and 75.67 for T, TA, TAG, LE and LEA, respectively. Application of this method to real samples was demonstrated and validated using rabbit serum samples. This work shows the promising use of conducting diamond as an amperometric detector in gradient LC, especially for the analysis of enkephalinamide and its metabolites.

Boron↗

Direct electrochemical oxidation of disulfides at anodically pretreated boron-doped diamond electrodes.

Anodically oxidized diamond electrodes have been used to oxidize disulfides, thiols, and methionine in aqueous acidic media and tested for amperometric detection of these compounds after chromatographic separation. Cyclic voltammetric signals for 1 mM glutathione disulfide (GSSG) were observed at 1.39 and 1.84 V vs SCE, the values being less positive than those of its as-deposited counterpart as well as glassy carbon electrode. The voltammetric and chronocoulometric results have indicated the high stability of the electrode with negligible adsorption. A positive shift in the peak potential with increasing pH indicated the attractive electrostatic interaction between the anodically oxidized diamond surface and the positively charged GSSG in acidic media that promoted its analytical performance. The results of the electrolysis experiments of disulfides and thiols showed that the oxidation reaction mechanism of glutathione (GSH) and GSSG involves oxygen transfer. Following separation by liquid chromatography (LC), the determination of both GSH and GSSG in rat whole blood was achieved at a constant potential (1.50 V vs Ag/AgCl), and the limits of detection for GSH and GSSG were found to be 1.4 nM (0.028 pmol) and 1.9 nM (0.037 pmol) with a linear calibration range up to 0.25 mM. These detection limits were much lower than those reported for the amperometry using Bi-PbO2 electrodes and LC-mass spectrometry, and the LC method using diamond electrodes were comparable with enzymatic assay in real sample analysis. The high response stability and reproducibility together with the possibility of regeneration of the electrode surface by on-line anodic treatment at 3 V for 30 min further support the applicability of anodically pretreated diamond for amperometric detection of disulfides.

Journal Article↗

Electrochemical oxidation of underivatized-nucleic acids at highly boron-doped diamond electrodes.

Boron-doped diamond (BDD) electrodes have been examined for the electrochemical oxidation of underivatized-nucleic acids in terms of single stranded and double stranded DNA. Cyclic voltammetry and square wave voltammetry have been used to study the oxidation reactions and to detect DNA without derivatization or hydrolysis steps. At the diamond electrode, at least two well-defined voltammetric peaks were observed for both single stranded and double stranded DNA. Diamond electrode is the first material to show a well-defined voltammetric peaks for adenine group oxidation directly in the helix structure of nucleic acid due to its wide potential window. For single stranded DNA, a third peak, related to the pyrimidine group oxidation was also observed. As-deposited diamond film with predominantly hydrogen-terminated surface exhibited superior performance over oxygen-terminated diamond in terms of sensitivity. However, by optimizing the ionic strength, sensitivity of O-terminated films could be improved. Linear calibration results have shown linearity of current with concentration in the range 0.1-8 microg mL(-1) for both guanine and adenine residues at as-deposited BDD. Detection limits (S/N = 3) of 3.7 and 10 ng mL(-1) for adenine and guanine residue in single stranded DNA, respectively, and 5.2 and 10 ng mL(-1) for adenine and guanine residue in double stranded DNA, respectively, were observed. This work shows the promising use of diamond as an electrochemical detector for direct detection of nucleic acids. The results also show the possibility of using the oxidation peak current of adenine group that is more sensitive for the direct detection of nucleicacids.

Animals↗

Electrochemical detection of carbamate pesticides at conductive diamond electrodes.

Conductive boron-doped diamond thin-film electrodes were used for the electrochemical detection of selected N-methylcarbamate pesticides (carbaryl, carbofuran, methyl 2-benzimidazolecarbamate, bendiocarb) after liquid chromatographic separation. Two kinds of detection methods were adopted in this study. In the first method, a direct detection of underivatized pesticides was carried out at an operating potential of 1.45 V versus Ag/AgCl, which resulted in the detection limits of 5-20 ng/mL (or 5-20 ppb) with S/N = 2 due to the low background current and wide potential window of the diamond electrode. In the second method, the detection limits were improved by subjecting the pesticide samples to alkaline hydrolysis in a separate step prior to injection. The phenolic derivatives obtained by alkaline hydrolysis oxidize at a relatively lower potential (0.9 V vs Ag/AgCl), which increases the sensitivity drastically. The advantage of the diamond electrode for the detection of phenolic derivatives is that it offers excellent stability in comparison to other electrodes. This method gives the detection limits of 0.6-1 ng/mL (or 0.6-1 ppb), which are well below the maximum residue levels allowed for carbaryl, carbofuran, and bendiocarb. While the lowest detection limits (LOD) obtained by the direct detection of pesticides are comparable to the those reported by the well-established HPLC-fluorescence, the LODs of the alkaline hydrolysis method are found to be even lower than the reported limits. On-line reactivation of the diamond electrode surface was shown to be possible by an anodic treatment of the electrode at approximately 3 V for 30 min in case of electrode fouling, which may occur after a prolonged use. Such a treatment damages the glassy carbon (GC) and metal electrodes, while the diamond electrode remains stable. These results suggest that the diamond electrode is superior to the other previously used electrodes such as GC and Kelgraf type for highly sensitive and stable detection of carbamate pesticides.

Carbamates↗

Electrochemical oxidation of chlorophenols at a boron-doped diamond electrode and their determination by high-performance liquid chromatography with amperometric detection.

Anodically pretreated diamond electrodes have been used for the detection of chlorophenols (CPs) in environmental water samples after high-performance liquid chromatographic (HPLC) separation. The anodization of as-deposited boron-doped polycrystalline diamond thin-film electrodes has enabled the stable determination of phenols over a wide concentration range. Prior to the HPLC analysis, a comparative study with ordinary glassy carbon, as-deposited diamond, and anodized diamond was made to examine the oxidative behavior of phenols by cyclic voltammety and flow injection analysis with amperometric detection. At anodized diamond electrodes, reproducible, well-defined cyclic voltammograms were obtained even at high CP concentration (5 mM), due to a low proclivity for adsorption of the oxidation products on the surface. In addition, after prolonged use, the partially deactivated diamond could be reactivated on line by applying a highly anodic potential (2.64 Vvs SCE) for 4 min, which enabled the destruction of the electrodeposited polymer deposits. Hydroxyl radicals produced by the high applied potential, in which oxygen evolution occurs, are believed to be responsible for the oxidation of the passivating layer on the surface. When coupled with flow injection analysis (FIA), anodized diamond exhibited excellent stability, with a response variability of 2.3% (n = 100), for the oxidation of a high concentration (5 mM) of chlorophenol. In contrast, glassy carbon exhibited a response variability of 39.1%. After 100 injections, the relative peak intensity, for diamond decreased by 10%, while a drastic decrease of 70% was observed for glassy carbon. The detection limit obtained in the FIA mode for 2,4-dichlorophenol was found to be 20 nM (S/N = 3), with a linear dynamic range up to 100 microM. By coupling with the column-switching technique, which enabled on-line preconcentration (50 times), the detection limit was lowered to 0.4 nM (S/N = 3). By use of this technique, anodized diamond electrodes were demonstrated for the analysis of CPs in drainwater that was condensed from the flue gas of waste incinerators.

Boron↗

The electrochemical oxidation of homocysteine at boron-doped diamond electrodes with application to HPLC amperometric detection.

The electrochemical oxidation of homocysteine was studied at as-deposited and anodized (oxidized) boron-doped diamond (BDD) thin film electrodes with cyclic voltammetry, flow injection analysis and high-pressure liquid chromatography with amperometric detection. At anodized boron-doped diamond electrodes, highly reproducible, well-defined cyclic voltammograms for homocysteine oxidation were obtained in acidic media, while as-deposited diamond did not provide a detectable signal. In alkaline media, however, the oxidation response was obtained both at as-deposited and anodized diamond electrodes. The potential sweep rate dependence of homocysteine oxidation (peak currents for 1 mM homocysteine linearly proportional to v(1/2), within the range of 0.01 to 0.3 V s(-1)) indicates that the oxidation involves a diffusing species, with negligible adsorption on the BDD surface at this concentration. In the flow system, BDD exhibited a highly reproducible amperometric response, with a peak variation less than 2%. An extremely low detection limit (1 nM) was obtained at 1.6 V vs. Ag/AgCl. In addition, the determination of homocysteine in a standard mixture with aminothiols and disulfide compounds by means of isocratic reverse-phase HPLC with amperometric detection at diamond electrodes has been investigated. The results showed excellent separation, with a detection limit of 1 pmol and a linear range of three orders of magnitude.

Boron↗

Selective amperometric detection of dopamine using OPPy-modified diamond microsensor system.

Highly boron-doped diamond microfiber electrodes (BDDMF) were fabricated and characterized by the use of Scanning Electron Microscopy (SEM), Raman spectroscopy, and cyclic voltammetry. Amperometric detection of dopamine (DA), a neurotransmitter was achieved at pH 7.0, using BDDMF electrodes. The interferences from ascorbic acid (AA) and DOPAC were efficiently eliminated by using overoxidized polypyrrole-modified BDDMF electrodes, which also increased the sensitivity for the detection of dopamine. The limit of detection (S/N = 3) for dopamine was 0.1 nM, which is one order lower than that observed for carbon microfiber electrodes (CMFE), and the linear dynamic range was obtained from 0.5 nM to 100 microM (r2 = 0.997). The amperometric response for 0.5 nM dopamine has shown high stability with an RSD of 5.4% (n = 5). Highly reproducible results were obtained with an RSD of 6.2% for 10 measurements of 1 nM DA taken during 10 h and also remained the same, during measurements for 7 days, with no variation in efficiency for rejection of AA and DOPAC.

Cardiotonic Agents↗

Voltammetric determination of L-cysteine at conductive diamond electrodes.

Boron-doped diamond (BDD) electrodes were used to examine L-cysteine (CySH) oxidation in alkaline media. The results of the voltammetric and polarization measurements showed that at BDD electrodes the overall CySH oxidation reaction is controlled by the initial electrochemical step, i.e., the oxidation of the CyS- electroactive species. The same conclusion was supported by the results of a study of pH effects. Conversely, at glassy carbon (GC) electrodes, the same reaction is controlled by the desorption of the reaction products. These results account for the poor response for CySH determination at GC compared to BDD. It was found that BDD exhibits excellent behavior for CySH determination, clearly outperforming GC. The results demonstrate that measurement of the peak current for CySH oxidation can be used as a basis for simple method for determining CySH in the micromolar concentration range by the use of BDD electrodes.

Cysteine↗

Electrochemical oxidation of histamine and serotonin at highly boron-doped diamond electrodes.

The electrochemistry of histamine and serotonin in neutral aqueous media (pH 7.2) was investigated using polycrystalline, boron-doped diamond thin-film electrodes. Cyclic voltammetry, hydrodynamic voltammetry, and flow injection analysis (FIA) with amperometric detection were used to study the oxidation reactions. Comparison experiments were carried out using polished glassy carbon (GC) electrodes. At diamond electrodes, highly reproducible and well-defined cyclic voltammograms were obtained for histamine with a peak potential at 1.40 V vs SCE. The voltammetric signal-to-background ratios obtained at diamond were 1 order of magnitude higher than those obtained for GC electrodes at and above 100 microM analyte concentrations. A linear dynamic range of 3-4 orders of magnitude and a detection limit of 1 microM were observed in the voltammetric measurements. Well-defined sweep rate-dependent voltammograms were also obtained for 5-hydroxytryptamine (5-HT). The characteristics of the voltammogram indicated lack of adsorption of its oxidation products on the surface. No fouling or deactivation of the electrode was observed within the experimental time of several hours. A detection limit of 0.5 microM (signal-to-noise ratio 13.8) for histamine was obtained by use of the FIA technique with a diamond electrode. A remarkably low detection limit (10 nM) was obtained for 5-HT on diamond by the same method. Diamond electrodes exhibited a linear dynamic range from 10 nM to 100 microM for 5-HT determination and a range of 0.5-100 microM for histamine determination. The FIA response was very reproducible from film to film, and the response variability was below 7% at the actual detection limits.

Boron↗