Failure mode of dental restorative materials under Hertzian indentation.

OBJECTIVE: To explore the application of Hertzian indentation testing to amalgam and GIC; study the failure behavior of the bi-layer structure of each material on a relatively soft substrate; and investigate the effect of thickness. METHODS: Amalgam (Lojic+, SDI, Bayswater, Australia) and ceramic-reinforced GIC (Advanced Healthcare, Tonbridge, UK) discs, 10 mm diameter, thicknesses ranging from 0.4 to 8.0 mm, were tested resting freely on a substrate (30% glass fibre-reinforced polyamide; E=10GPa, 10 mm diameter and 5 mm thick). Increasing load was applied to the center of the disc by a 20 mm-diameter hard steel ball until fracture occurred. Acoustic emission sensing was used as a supplemental method for crack detection. The load at the first crack was recorded. Fracture surfaces were observed under SEM to identify the crack initiation site and the failure mode. RESULTS: The main failure mode of both materials shifted from bottom-initiated radial cracking to near-contact cone cracking or subsurface plastic deformation as the thickness was increased. There was a wide thickness range for the transition of the failure mode for amalgam. Failure load was proportional to the square of thickness for amalgam, except for deviations at small and very large thickness; for the GIC, it was proportional to the thickness to the power approximately 1.6, except for thin layers. SIGNIFICANCE: The Hertzian indentation test can be applied to investigate the failure behavior of amalgam and GIC in addition to ceramics, for which purpose it may have value as a routine test. Failure mode changed with specimen thickness. The importance of considering both failure mode and failure load or strength is emphasized.

Dental Amalgam↗

Methyl methacrylate monomer-polymer equilibrium in solid polymer.

OBJECTIVE: Poly(methyl methacrylate) (PMMA) is commonly processed in dentistry by thermally initiating the free-radical polymerization of methyl methacrylate (MMA). Residual MMA, a tissue irritant, is a concern. The concentration of MMA ([MMA]) versus time and temperature was studied to identify optimum processing conditions. MATERIALS AND METHODS: One hundred milligram portions of plain and dental PMMA powders were incubated (10-170 degrees C, 1-384 h), with and without 6.0 microL MMA added. After incubation, [MMA] was determined by GC. RESULTS: For plain PMMA alone, equilibrium was attained in about 100 h. The equilibrium data for log[MMA] versus 1/T was better fitted by a quadratic than a straight line, and formed an upper bound to the values of [MMA] when PMMA was incubated with MMA at temperatures > approximately 120 degrees C. The response surface for [MMA] versus log(time) and reciprocal temperature was fitted. An 'overshoot' in the equilibration process was identified, and postulated to be due to a rapidly formed intermediate of unknown chemistry. SIGNIFICANCE: Minimization of the residual MMA in acrylic denture bases prepared by processing a mixture of PMMA and MMA is important for reasons of mechanical properties and irritancy. The response surface mapped here allows direct identification of the optimum processing conditions.

Chemical Phenomena↗

Curing-light attenuation in filled-resin restorative materials.

OBJECTIVE: To characterize the attenuation of the curing light in filled resin restorative materials (FRRMs) to aid understanding of curing depth. MATERIALS AND METHODS: One hundred and eighty materials of various shades from several manufacturers were tested in various ways. One set (66 materials) was used to determine the applicability of Lambert's Law using a quartz-tungsten-halogen curing light (Optilux 400, Demetron Research) by measuring the transmitted light with a dental radiometer (Cure Rite, EFOS) for successive thicknesses of ground 10mm diameter specimens from 3 to 0.5 mm in 0.5 mm steps. A second set (17 materials) were similarly tested with separate specimens from 1 to 5mm in thickness using a transmission densitometer (DT1405, RY Parry) fitted with a curing-light dichroic filter. For a third (overlapping) set (165 materials), the 1 mm pure (reflectance-free) optical density (D1 value) was determined from two specimens, approximately 1 and approximately 2 mm thick using the densitometer as above. From D1 the critical thickness (x(CRIT)), identified as depth of cure (DoC) for an excess surface exposure factor of 2, was calculated. RESULTS: Lambert's Law was found to hold with no evidence of appreciable differential absorption effects. Attenuation coefficient and D1 were significantly correlated (P < 1 x 10(-13)). D1 varied between about 0.23 and 0.72, for corresponding x(CRIT) values of 1.3 and 0.4 mm. There was no correlation between D1 and reflectance (P > 0.09), and no systematic effect due to shade letter, but a highly significant (P < 7.5 x 10(-8)), but weak (-0.066 mm/unit), correlation between shade number and D1. SIGNIFICANCE: Depth of cure can be calculated directly from the D1 value determined via simple optical density measurements on two specimens providing that (a) an irradiation time can be determined for the surface of a specimen to be "sufficiently" cured (i.e. for DoC = 0 precisely), and (b) an excess internal surface exposure ratio can be chosen such that the corresponding DoC is attained in a practicable irradiation time.

Composite Resins↗

Non-inverse-square force-distance law for long thin magnets.

OBJECTIVE: There is a need for a means of characterizing permanent magnets for dental applications, in particular the force-distance relationship. Problems with determining this on the basis of elementary theory prompted consideration of a model system of long thin magnets. MATERIALS AND METHODS: (a) The force exerted by rod-shaped magnets (Alnico V, 3mm diameter, 170 mm long) perpendicular to a large steel plate, as a function of distance, at small separations (<5mm), was determined for 85 examples. (b) Numerical modelling for a "polar disc" or sheaf of dipoles was conducted to test an alternative physical representation to the normally assumed simple dipole. (c) Exploratory curve-fitting trials were undertaken on the basis of known boundary conditions and observation of actual behaviour. RESULTS: The inverse square law for a point-like pole was found not to apply to the experimental data in any region. The polar disc model was found to provide a very good fit to the experimental data over the whole range tested, but only when an offset ( approximately 1mm) of the pole position from the magnet face was assumed, and that this offset experienced an exponential-decay pole-position relaxation (typically 0.4-1.5mm). The fitted pole strength was of the order of 0.18 mAm. SIGNIFICANCE: The implications of these results are that the commonly used elementary view of a simple dipole magnet is of little value for understanding the force-distance relationship and cannot be used as a basis for dental device characterization.

Dental Stress Analysis↗

Minimization of the inevitable residual monomer in denture base acrylic.

OBJECTIVES: Residual monomer ([MMA](R)) in denture base acrylic continues to be of concern. The response surface of concentration vs. time and temperature for the equilibration of methyl methacrylate (MMA) and its polymer (PMMA) allows a prediction of the time to the minimum at any temperature for a closed system. It was the purpose here to determine whether this prediction applies to normal denture base processing, and whether optimum conditions could be identified. METHODS: Denture bases were processed following normal laboratory procedures, including pre-cure for 3 h at 70 degrees C for all tests. Commercial powder and liquid were used at either 95 or 100 degrees C, or a plain PMMA powder and the same liquid at 95 degrees C, for times ranging from 5 to 192 h. Residual MMA was determined by gas chromatography. RESULTS: [MMA](R) decreased steadily from approximately 0.25% to as low as approximately 0.07% with increasing time at temperature, but did not approach equilibrium. The rate of diffusive loss of MMA appears to exceed the rate of depolymerization. SIGNIFICANCE: Residual monomer is inevitable for all PMMA-based products no matter what the curing conditions are. However, extended time at high temperature can allow low values to be attained, and the time allowed can compensate for processing temperatures somewhat lower than the ordinarily recommended 100 degrees C. It is suggested that overnight processing at 95 degrees C should be adopted to minimize [MMA](R) and save energy. This result is of importance for work at high altitude.

Acrylic Resins↗

Discharge of lubricant from air turbine handpieces.

OBJECTIVE: To demonstrate and quantify the discharge of lubricating oil from high-speed air turbine handpieces whilst running. MATERIALS AND METHODS: Dye-marked oil (Kavospray, KaVo) was used to lubricate four handpieces (Quiet-Air, Midwest) and the air discharged from around the lower bearing was directed at the moving chart paper on a recorder whilst running for 40 minutes. Secondly, seven new handpieces (Quiet-Air, 300SE, Midwest; Topair 796, Topair 795, W+H; VIP-Sigma, Pana-air, NSK; Lares, Lares Research) were cleaned, weighed and then lubricated with unmarked oil (Kavospray, KaVo). Oil discharge was determined gravimetrically over runs of 240 minutes. Data were fitted to the logistic dose response function. RESULT: The dye-marked oil tests showed that oil was discharged for at least 40 minutes in the direction of the bur. The gravimetric tests showed that oil continued to be discharged up to at least 240 minutes, and that the usual practice of removing excess lubricant by running for 1-2 minutes was ineffective in preventing cut-surface contamination. SIGNIFICANCE: Bonding procedures in dentistry may be jeopardised by oil contamination from handpiece lubricants. Decontamination with a detergent is suggested as a means of ensuring effective adhesive dentistry.

Air Pollution, Indoor↗

Defects in ProTaper S1 instruments after clinical use: fractographic examination.

AIM: To investigate the mode of failure of a brand of nickel-titanium instruments separated during clinical use, by detailed examination of the fracture surface. METHODOLOGY: A total of 122 ProTaper S1 instruments were discarded from an endodontic clinic at a stomatological school in China over a period of 17 months; 28 had fractured. These fractured instruments were ultrasonically cleaned, autoclaved and then examined under a scanning electron microscope. From the lateral view the fracture was classified into 'torsional' or 'flexural'. The specimens were then re-mounted and the presence of characteristics of shear failure and fatigue striations was recorded under high-power view of the fracture surface. The difference in the mean lengths of fractured segment between the shear and fatigue groups was compared using Student's t-test. RESULTS: Twenty-seven separated instruments were available for analysis. Under low-power magnification, only two fell into the category of 'torsional' failure when examined laterally; the others appeared to be 'flexural'. Close examination of the fracture surface revealed the presence of fatigue striations in 18 specimens. Nine instruments (including the two putative 'torsional' failures above) fell into the shear fracture group, in which fatigue striations were absent or characteristics of shear failure of the material were found. The mean length of fractured segments resulting from fatigue failure (4.3+/-1.9 mm) was significantly greater than that for shear failure (2.5+/-0.8 mm) (P<0.001, two-sample t-test). CONCLUSIONS: Examination of the fracture surface at high magnification is essential to reveal features that may indicate the possible origin of cracks and the mode of material failure. Macroscopic or lateral examination of separated instruments would fail to reveal the true mechanism of failure. Fatigue seems to be an important reason for the separation of rotary instruments during clinical use.

Dental Alloys↗

Hydroxyapatite solubility in simple inorganic solutions.

OBJECTIVE: To use solid titration and laser-scattering end-point detection to determine the hydroxyapatite (HAP) solubility isotherm at 37 degrees C in a plain KCl solution, with CO(2) present, and with additional phosphate. DESIGN: Pulverised HAP solid was used to perform a titration to saturation. A very sensitive detector capable of detecting the light scattered at small forward angles from a laser beam was adopted to monitor the onset of precipitation (or failure to dissolve) near the equilibrium point. Each addition of HAP solid caused a step increase in scattered light and this signal decreased quasi-exponentially with time. When a steady but elevated scattering was obtained, small portions of 1M HCl were added to lower the pH by about 0.5-2 units, according to need, to dissolve excess solid and allow a further titration. The scatter signal and pH data, plotted against the amount of HAP added, were used to estimate the actual end-point by interpolation and thus construct each point on the solubility isotherm. RESULTS: The solubility isotherm for HAP in plain KCl solution in the absence of CO(2) obtained now differs substantially from the results of previous solubility studies (i.e. much lower). The increase in solubility due to CO(2) reported earlier was confirmed, while the effect of excess phosphate was found to be to increase the apparent solubility of HAP, contrary to elementary mass-action expectations. CONCLUSIONS: The solid titration method is a more reliable approach than that of conventional excess solid method with respect to the determination of the HAP-carrying capacity. The solubility of HAP appears to be substantially lower than previously reported, and a reconsideration of all aspects of the system is warranted.

Biocompatible Materials↗

Validation of ion chromatography for human salivary anionic analysis.

OBJECTIVE: Assess the applicability of ion chromatography (IC) for human saliva studies. MATERIALS AND METHODS: The behaviour of an ion chromatograph (DX-100, Dionex) in the analysis of human saliva was examined in the following respects: calibration, reproducibility, recovery, and effect of pre-treatment conditions (dilution, temperature). The eluents used were 1.7 mM NaHCO3 + 1.8 mM Na2CO3 + 100 mg/L p-cyanophenol (2 mL/min) and 1.6 mM perfluorobutyric acid + 0.3 mM sodium hydroxide (0.3 mL/min) for inorganic and organic anions, respectively. RESULTS: The calibration curves were satisfactorily linear, but did not have unit slope (log-log plot) in the case of chloride, phosphate, sulphate and acetate. No significant effects were detected for centrifugation temperature, or between runs on the same occasion. CONCLUSION: IC appears to be a valuable technique well-suited to the efficient analysis of several salivary anions.

Anions↗

Human salivary anionic analysis using ion chromatography.

OBJECTIVE: To survey concentrations and time-variability of the major anions of human saliva using ion chromatography (IC). MATERIALS AND METHODS: Resting saliva samples after overnight fasting, obtained under standardized conditions in time-series for 10 subjects, were analysed for chloride, phosphate, nitrate, sulphate, thiocyanate, acetate and lactate. A second group of five subjects provided mixed saliva as before, and in addition a sample of parotid saliva collected immediately afterwards using a Lashley cup. Analysis was by ion chromatography (DX-100, Dionex) using 1.7 mM NaHCO3 + 1.8 mM Na2CO3 + 100 mg/L p-cyanophenol (2 mL/min) and 1.6 mM perfluorobutyric acid + 0.3 mM sodium hydroxide (0.3 mL/min) as eluents for inorganic and organic anions, respectively. RESULTS: The time-series data showed great natural variability. Analysis of the correlations showed that the concentration of nitrate was uncoupled from those of the other anions. Lactate was not detected. Parotid saliva showed marked differences from mixed saliva, most notably the absence of acetate and the presence in two instances of lactate. Bromide, nitrite and citrate were not detected. CONCLUSIONS: Acetate is a major component of the oral chemical environment. Simultaneous analyses permit the investigation of the relationships between component concentrations that otherwise might have been difficult to study.

Acetates↗

Effects of strain rate and temperature on the mechanical properties of resin composites.

OBJECTIVE: To evaluate the effects of strain rate and temperature on the mechanical properties of resin composite restorative materials (RCs) and to investigate the construction of temperature--strain rate equivalence 'master curves'. METHODS: Four visible light-cured resin composite RCs, all of shade A3, were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein), Filtek Z250 (FZ) (3M, St Paul, MN, USA) and Prodigy Condensable (PR) (Kerr, Orange, CA, USA). Bar specimens (10 x 1.5x 16.0 mm3) were cured for 50 s at an irradiance of 500 mW cm(-2) and were randomly distributed into groups of six for each type of material. All specimens were stored in artificial saliva at pH 6, for 7d. The specimens tested at 12, 24 and 37 degrees C were stored at the corresponding temperature but those tested at 0 degrees C were stored at 24 degrees C. Three-point bend tests for flexural strength (F), flexural modulus of elasticity (E) and total energy to failure (W) were performed at cross-head speeds (XHS) of 0.1, 1.0, 10, 50 and 100 mm min(-1) for all materials as well as at 0.01, 0.03, 0.2 and 0.5 mm min(-1) for some materials. RESULTS: There was a common pattern of behavior across materials. At constant temperature, F showed a slight variation with cross-head speed, with a broad peak in the region of 1-10 mm min(-1). E, on the other hand, showed a more marked and steady increase with XHS at all temperatures except at 0 degrees C, where it tended to level off above about 10 mm min(-1). In contrast, the values of W showed a decline with increasing XHS, except at 37 degrees C where an initial rise followed by a decline was observed. At constant XHS, increase in temperature caused a small, but highly significant (P < 10(-3)) decline in F but a marked decline in E. W, again in contrast to Fand E, showed a general increase with temperature. A master curve model for the temperature-strain-rate equivalence was fitted to the E and W data (all P < 10(-5)) and the fitted parameters interpreted in terms of strain rate and temperature sensitivity. SIGNIFICANCE: The mechanical properties of RCs are very sensitive to the test conditions of strain rate and temperature. This implies that properties determined at any temperature other than 37 degrees C, or at only one cross-head speed (or only one strain rate) are inadequate to describe their behavior in service. The master curve principle is applicable to RCs and can be used, inter alia, to determine property values under other than tested conditions. Conditions of testing in regard to XHS and temperature, as well as other factors, should clearly be stated to enable proper comparisons between studies, but more importantly the use of standardized test conditions is overdue.

Acrylic Resins↗

Aspects of water sorption from the air, water and artificial saliva in resin composite restorative materials.

OBJECTIVE: Primarily to establish whether artificial saliva (AS) at 37 degrees C is essential as a clinically relevant environment for testing filled, resin composite restorative materials. The effect of other storage conditions was also investigated for comparison and controls: desiccation, exposure to the laboratory atmosphere, high humidity cabinet, saturated water vapor, and deionized water. METHODS: Two visible light-cured products were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein). Bar specimens (26 x 1.5 x 1.0 mm(3)) were cured at five overlapping spots for 60s per spot and randomly distributed into groups of six. Trial 1: one group of each material was exposed first to atmospheric air at 24 degrees C, approximately 50% RH (24WV(50)), then to water vapor at 37 degrees C, approximately 97% RH (37WV(97)), and then immersed in deionized water at 37 degrees C (37DW). Trial 2 used three groups of each material, one first exposed to 37WV(97) followed by 37DW, the other two were immediately immersed in 37DW or artificial saliva (37AS). Trial 3: two groups of each material were vacuum desiccated at 37 degrees C, then exposed to 37 degrees C, approximately 100% RH (37WV(100)), then immersed in 37DW or 37AS. Trial 4: four groups of HR were treated similarly to Trial 3; one was left under desiccation, and another in 37WV(100) for the remaining period. Three-point bend tests for flexural strength (F), flexural modulus (E), and total energy to failure (W) were performed at the end of Trials 2-4. RESULTS: Environmental moisture absorption was substantial at 24WV(50)(c. 0.2%), at least 40% of that in 37DW (HR: c. 0.7%, TC: c. 0.5%). Saturation was achievable in 37WV(100). Mass loss on desiccation (HR: c. 0.4-0.5%, TC: c. 0.25%) was reversible in 37WV(100). There were some significant effects of exposure conditions on mechanical properties (e.g. F for HR: after desiccation, 85.7+/-1.4MPa; after 37WV(100), 73.2+/-3.6MPa; difference: p<0.0002), but overall the results were unclear. After a rapid gain in mass, there was a gradual loss in both 37DW and 37AS for both materials, slightly more in 37AS than 37DW. SIGNIFICANCE: Water vapor absorption is substantial, hence attention must be paid to the laboratory working environment and conditions of storage and testing, i.e. temperature and RH must be stated to assist interpretation of data and comparisons between studies. Test conditions need to be standardized and with reference to normal oral conditions, immediate immersion in artificial saliva at 37 degrees C is the preferred treatment for these materials, whatever time of testing is chosen.

Absorption↗

Polymerization of resin composite restorative materials: exposure reciprocity.

OBJECTIVE: To examine whether there is reciprocity between irradiation time and irradiance with regard to the mechanical properties of filled, resin composite restorative materials (RCs). METHODS: Four visible light-cured RCs, all of shade A3, were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein), Filtek Z250 (FZ) (3M, St Paul, MN, USA) and Prodigy condensable (PR) (Kerr, Orange, CA, USA). Bar specimens (1.0 x 1.5 x 16.0 mm(3)) were cured at irradiances (I) ranging from 25-1500 mW/cm(2) and irradiation times (t) of 1-3000 s. Six specimens at 250 combinations of t and I were prepared and stored in artificial saliva of pH 6, at 37 degrees C for 7d before performing three-point bend tests for flexural strength (F), flexural modulus (E) and total energy to failure (W). Contour plots of property value vs. t and I on log scales were prepared. RESULTS: The contour plots showed three regions: unset at low I.t, a plateau corresponding to more or less full property development, and connecting ramp. The boundary between the plateau and the ramp suggests the minimum acceptable exposure. No practical lower limit to irradiance was detected, but there may be no benefit from increasing I beyond about 1,000 mW/cm(2). The slopes of the contours in the log-log plots provided a test of the hypothesis of reciprocity. These slopes were approximately -1.5 for HR, TC and PR; and approximately -1 for FZ, compared with the expected value of -1. The general hypothesis therefore fails. The existence of localized maxima in property values is further evidence of that failure, even for FZ. SIGNIFICANCE: Dentists may use any lamp, including LED sources, and attain satisfactory results providing irradiation time is long enough. Manufacturers ought to supply a graph indicating the minimum acceptable exposure for each product for specified curing lamps. Calculations based on total energy delivered to guide irradiation protocols are invalid and do not recognize product behavior.

Acrylic Resins↗

Stress distribution and failure mode of dental ceramic structures under Hertzian indentation.

OBJECTIVES: To understand better the clinically-relevant failure of the ceramic in ceramic-cement-substrate structures under Hertzian indentation, including the effects of supporting substrate modulus and ceramic thickness on the stress distribution in the ceramic. METHODS: Discs (thickness, T(c)=0.2, 0.6, 1.2, 1.6, 2.0, 2.4 mm) of a glass-ceramic material (IPS Empress 2, Ivoclar) were cemented (Variolink II, Vivadent) to flat polymer substrates with modulus of elasticity E(s) of 2, 6 and 10 GPa. The top surface of the ceramic-cement-substrate structure was loaded by a 20 mm radius spherical indenter until the initial failure of the ceramic occurred. The finite element method was used to analyse the stress distribution under such Hertzian indentation, varying E(s) and T(c), as well as calculating the maximum tensile stress based on the experimentally observed failure load and contact radius. The failure initiation site of the ceramic was identified by fractography using scanning electron microscopy. RESULTS: The tensile stress concentration at the cementation surface of the ceramic was the predominant factor controlling the ceramic failure. Failure load increased with increase of E(s), while the maximum tensile stress at the cementation surface of the ceramic clearly decreased. Failure load increased logarithmically with ceramic thickness, but the critical tensile stress increased linearly. SIGNIFICANCE: The failure mode observed clinically for ceramic restorations was reproduced in laboratory tests.

Aluminum Silicates↗

Effect of burnout temperature on strength of gypsum-bonded investments.

OBJECTIVE: To investigate the variation of the strength of gypsum-bonded dental investments with burnout temperature. METHODS: The disc-rupture test was employed at burnout temperatures ranging from 450 to 800 degrees C for four products (Beauty Cast, Cristobalite, Novocast (all WhipMix) and Deguvest California (Degussa)). In this test, an investment disc is created inside an investment mold such that it forms a diaphragm across the mold space, being an integral part of the mold. Copper was cast into molds of this type, and whether the disc had ruptured or not was determined by inspection when cold. The amount of copper cast in successive tests was varied in staircase fashion up and down depending on whether the disc survived or failed. The strength of the investment was represented by the 50% point of the transition from survival to rupture. RESULTS: The strength of gypsum-bonded investment is temperature sensitive, there being marked differences between the products tested. Overall, the strength ranking (temperature range average/MPa) was: Cristobalite (10.1)>Beauty Cast (7.8)>Novocast (5.1)>Deguvest California (3.4). The strength ranking at high temperatures differs from that known for the room temperature values. SIGNIFICANCE: The use by manufacturers of room-temperature strength data conveys no information about high temperature behavior. Investment properties should be optimized by reference to behavior under casting conditions.

Calcium Sulfate↗

Sintering of dental porcelain: effect of time and temperature on appearance and porosity.

OBJECTIVE: Mechanical condensation of powder-method dental porcelains can only achieve a limited effect--the majority of consolidation and porosity elimination is achieved by sintering. However, there is a surprising lack of information on the process in the literature, and the effects of the two basic conditions of sintering, time and temperature, are very poorly described despite theoretical expectations. The present study was to investigate the effects of these conditions on porosity and to consider its relationship to the recognizable firing stages of low and high biscuit, and other aspects of appearance, with a view to schedule recommendations. METHODS: The variation of appearance, pore form and percentage porosity with sintering time and temperature was studied for five dental dentine porcelains, two aluminous: Alpha (Vita Zahnfabrik, Bad Säckingen, Germany) and Vitadur-N (Vita); and three feldspathic: Omega (Vita), VMK68 (Vita) and Carmen (Esprident, Ispringen, Germany). Disc specimens were sintered for 0-1000 min over 750-1100 degrees C in a systematic search pattern to establish limits of acceptable appearance (high biscuit to not quite slumped). Porosity was measured using an image analyser on specimens fired for sintering times of 24 and 30 s; 1, 3, 6 and 30 min; 1, 5, 10, 15 and 20 h; with sintering temperatures from 750 to 950 degrees C for Carmen and 800-1050 degrees C for the others, all with 50 degrees C increments. Measurements were made on a ground and polished surface (1 microm diamond), five fields on each of five specimens per condition. The percentage porosity, pore count, median pore area and pore size distribution were analyzed. RESULTS: The boundaries of the acceptable appearance areas in maps of sintering temperature vs. sintering time were clearly delineated; analysis showed that they may be related to the activation energy of the diffusive processes occurring during sintering. Minimum porosity was obtained at high temperature and short time, close to but not consistently coincident with the manufacturers' recommendations. There is also a conductivity-related minimum sintering time at high temperatures. The theoretical reduction on prolonging sintering at high temperature was not a general result, and porosity increased markedly in the feldspathic porcelains, particularly VMK-68. SIGNIFICANCE: The reduction of porosity of dentine porcelain is much more sensitive to temperature than to time. It is possible systematically to identify optimum conditions using the present approach. Detailed study of the effects of formulation on the sintering process may be made by reference to the activation energy.

Algorithms↗

Lead exposure.

Explore the source record for details and available documents.

Environmental Exposure↗

Effect of storage conditions on calcium sulphate hemihydrate-containing products.

OBJECTIVE: Dental gypsum products are liable to deterioration on exposure to the air because of reaction between calcium sulphate hemihydrate and water vapour. The purpose of this investigation was to refine the knowledge of the conditions and rates at which this occurred for a representative selection of such products with a view to improved storage recommendations. MATERIALS AND METHODS: Absorption of water from controlled atmospheres (25-40 degrees C, 75-99% RH) was monitored gravimetrically for a dental artificial Stone, Plaster of Paris, an Impression plaster and a gypsum-bonded Investment. RESULTS: An initial steady absorption stage was followed by a transition to a rapid absorption; this led to a completion stage as the presumed hydration reaction approached completion. The logarithm of time of the transition showed approximately linear dependence on the relative humidity (and not on water vapour pressure as might have been expected) and a slight but significant (P<0.005) negative dependence on temperature in the range 25-35 degrees C for Stone, Plaster of Paris and the Impression plaster, but not for the Investment (P>0.5). The behaviour for the first three materials at 40 degrees C departed significantly from the temperature-dependent trend (P<0.05) while the Investment showed no such effect. The absorption by the Investment was substantially faster than for the other materials. SIGNIFICANCE: There is no evidence to suggest that there is a 'safe' humidity for exposure to the atmosphere although for the Stone and Plasters at RH <70% in excess of 1000 h is predicted to be necessary before rapid reaction commences. For the Investment, the equivalent time at 70% RH is 1d.

Absorption↗