A photobiological and photophysical-based study of phototoxicity of two chlorins.

To understand the fundamental determinants of phototoxic efficacy and absorbed photodynamic dose, the triplet state and photobleaching quantum yields in living cells, cellular uptake, intracellular localization, and correlation with cell viability were studied for the two purpurins tin ethyl etiopurpurin 1 (SnET2) and tin octaethylbenzochlorin (SnOEBC) in ovarian cancer cells (OVCAR5). Although the triplet yields of these two photosensitizers were not significantly affected by cellular incorporation, the photobleaching yields were shown to be 3 orders of magnitude higher for cellular-bound sensitizer than for free or albumin-bound photosensitizer and higher for SnET2 than for SnOEBC for all of the cases. The intracellular concentration of SnOEBC was half that of SnET2 after 3 h- and 24 h-incubation times for both 0.1 microM and 1.0 microM incubation concentrations. Despite the lower concentrations of SnOEBC, the phototoxicity of the two photosensitizers was comparable at 1-microM incubation concentration and was up to 10-fold higher for SnOEBC at the lower concentration. The subcellular localization established using confocal microscopy and molecular probes showed that both photosensitizers were primarily lysosomally localized. SnOEBC, however, had an extra-lysosomal, mitochondrial localization component. The photophysical measurements allowed calculation of the intracellular singlet oxygen production, which indicated that the photosensitizer-light dose reciprocity was limited by photobleaching for SnET2 but only minimally for SnOEBC, and this was confirmed through cell-survival studies. Taken together, these data indicate that the critical determinant of differences in phototoxicity between the two molecules was their relative rates of photobleaching and their subcellular localization. The study points to the importance of combining photosensitizer uptake and localization with photophysical measurements in the relevant biological milieu to reasonably interpret and/or predict photosensitization efficacies.

Cell Survival↗

Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric field phases as a function of receiver position around the periphery of the imaging field-of-view vary rapidly often undergoing changes of greater than pi radians especially when the object contrast and illumination frequency increase. In this paper, we introduce a modified form of a Maxwell equation model-based image reconstruction algorithm which directly incorporates log-magnitude and phase of the measured electric field data. By doing so, measured phase variation can be unwrapped and distributed over more than one Rieman sheet in the complex plane. Simulation studies and microwave imaging experiments demonstrate that significant image quality enhancements occur with this approach for large high-contrast objects. Simple strategies for visualizing and unwrapping phase values as a function of the transmitter and receiver positions within our microwave imaging array are described. Metrics of the degree of phase variation expressed in terms of the amount and extent of phase wrapping are defined and found to be figures-of-merit which estimate when it is critical to deploy the new image reconstruction approach. In these cases, the new algorithm recovers high-quality images without resorting to the use of a priori information on object contrast and/or size as previously required.

Algorithms↗

Analysis of acetic acid-induced whitening of high-grade squamous intraepithelial lesions.

Immature and dysplastic cervical squamous epithelium whitens after the application of acetic acid during a colposcopic examination. The whitening process occurs visually over several minutes and subjectively discriminates between dysplastic and normal tissue. In this work, examples of the acetowhitening process are detailed in three ways: the color-imaged colposcopic appearance of the acetowhitening of high-grade cervical intraepithelial neoplasia (CIN 2/3), the kinetics of these reflectance patterns transformed to reduce noise in the signal, and a self-normalized green to red ratio measurement of the kinetics of these reflectance patterns. A total of six patients with biopsy confirmed CIN 2/3 were examined to obtain a set of timed images tracking the acetowhitening and the whitening-decay process over the course of 5-10 min. Regions of normal mature squamous epithelium within the same patients were also followed as an internal control. We determined that the temporal change over a 10 min time period in the ratio of green to red light intensities, taken from the respective color channels of the CCD, provides a reliable measure to clearly distinguish CIN 2/3 from normal cervical epithelium. This imaging and data normalization procedure may be applied to cervical lesions of different grades, to determine if a quantitative estimate provides predictive value during the colposcopic diagnosis.

Acetic Acid↗

Quantitative hemoglobin tomography with diffuse near-infrared spectroscopy: pilot results in the breast.

The authors describe what is, to the best of their knowledge, the first quantitative hemoglobin concentration images of the female breast that were formed with model-based reconstruction of near-infrared intensity-modulated tomographic data. The results in 11 patients, including two with breast tumors with pathologic correlation, are summarized. Hemoglobin concentration appears to correlate with tumor vascularity without the need for exogenous contrast material and thereby has intrinsic diagnostic value.

Adult↗

Analysis of the heterogeneity of pO2 dynamics during photodynamic therapy with verteporfin.

Photodynamic therapy (PDT) with verteporfin provides a reliable way to destroy malignant tissues. Changes in the blood flow and oxygen partial pressure (pO2) during verteporfin-PDT were studied here in the tumor tissue of the rat mammary R3230Ac carcinoma model. Oxygen microelectrodes (6-12 microns tip diameter) were used to measure the transients locally within tumors during intravenous injection of 1.0 mg/kg verteporfin followed by irradiation 15 min later with 690 nm light at 200 mW/cm2, for a cumulative dose of 144 J/cm2. The observed changes in pO2 were heterogeneous and there was a difference in the response of low-pO2 regions relative to higher-pO2 regions. The change in pO2 in hypoxic tissue regions (pO2 < 8 mmHg) had acute pO2 loss after treatment, whereas the response in regions of higher pO2 (> 8 mm Hg) was more heterogeneous with some areas maintaining their pO2 value after treatment was completed. Blood flow measurements taken on a subset of the animals indicated a significant loss in flow during the initial light delivery that remained low after treatment, indicating some vascular stasis. The results suggest that hypoxic or poorly perfused vessels may be more susceptible to acute stasis than normoxic vessels in this treatment protocol.

Animals↗

In vivo NADH fluorescence monitoring as an assay for cellular damage in photodynamic therapy.

In this study the endogenous fluorescence signal attributed to reduced nicotinamide adenine dinucleotide (NADH) has been measured in response to photodynamic therapy (PDT)-induced damage. Measurements on cells in vitro have shown that NADH fluorescence decreased relative to that of controls after treatment with a toxic dose of PDT, as measured within 30 min after treatment. Similarly, assays of cell viability indicated that mitochondrial function was reduced immediately after treatment in proportion to the dose delivered, and the proportion of this dose response did not degrade further over 24 h. Measurements in vivo were used to monitor the fluorescence emission spectrum and the excited state lifetime of NADH in PDT-treated tissue. The NADH signal was defined as the ratio of the integrated fluorescence intensity of the 450 +/- 25 nm emission band relative to the fluorescence intensity integrated over the entire 400-600 nm range of collection. Measurements in murine muscle tissue indicated a 22% reduction in the fluorescence signal immediately after treatment with verteporfin-based PDT, using a dose of 2 mg/kg injected 15 min before a 48 J/cm2 light dose at 690 nm. Control animals without photosensitizer injection had no significant change in the fluorescence signal from laser irradiation at the same doses. This signal was monotonically correlated to the deposited dose used here and could provide a direct dosimetric measure of PDT-induced cellular death in the tissue being treated.

Animals↗

Estimation of oxygen distribution in RIF-1 tumors by diffusion model-based interpretation of pimonidazole hypoxia and eppendorf measurements.

Numerical simulations of oxygen diffusion from the capillaries in tumor tissue were used to predict the capillary oxygen supply within and near hypoxic regions of the RIF-1 tumor. A finite element method to simulate the oxygen distribution from a histology section is presented, along with a method to iteratively estimate capillary oxygen concentrations. Pathological structural data for these simulations came from sections of the tumor stained with hematoxylin and eosin and were used to define the capillary positions and shapes, while overlapping regions of low oxygen concentration were defined by the hypoxia marker pimonidazole. These simulations were used to calculate spatial maps of the oxygen concentration and were tested for their ability to reproduce Eppendorf pO(2) histograms from the same tumor line. This simulation study predicted that capillary oxygen concentrations ranged from zero to above 20 microM, with a dominant peak in the hypoxic regions showing 78% of capillaries with less than 1 microM oxygen concentration, compared to only 12% in the non-hypoxic regions. The results were not highly sensitive to the metabolic oxygen consumption rate, within the range of 2 to 16 microM/s. This numerical method for oxygen capillary simulation is readily adaptable to histology sections and provides a method to examine the heterogeneity of oxygen within the capillaries and throughout the tumor tissue section being examined.

Animals↗

Image analysis for discrimination of cervical neoplasia.

Colposcopy involves visual imaging of the cervix for patients who have exhibited some prior indication of abnormality, and the major goals are to visually inspect for any malignancies and to guide biopsy sampling. Currently colposcopy equipment is being upgraded in many health care centers to incorporate digital image acquisition and archiving. These permanent images can be analyzed for characteristic features and color patterns which may enhance the specificity and objectivity of the routine exam. In this study a series of images from patients with biopsy confirmed cervical intraepithelia neoplasia stage 2/3 are compared with images from patients with biopsy confirmed immature squamous metaplasia, with the goal of determining optimal criteria for automated discrimination between them. All images were separated into their red, green, and blue channels, and comparisons were made between relative intensity, intensity variation, spatial frequencies, fractal dimension, and Euler number. This study indicates that computer-based processing of cervical images can provide some discrimination of the type of tissue features which are important for clinical evaluation, with the Euler number being the most clinically useful feature to discriminate metaplasia from neoplasia. Also there was a strong indication that morphology observed in the blue channel of the image provided more information about epithelial cell changes. Further research in this field can lead to advances in computer-aided diagnosis as well as the potential for online image enhancement in digital colposcopy.

Adolescent↗

Calibration of near-infrared frequency-domain tissue spectroscopy for absolute absorption coefficient quantitation in neonatal head-simulating phantoms.

Frequency-domain tissue spectroscopy is a method to measure the absolute absorption coefficient of bulk tissues, assuming that a representative model can be found to recover the optical properties from measurements. While reliable methods exist to calculate absorption coefficients from source-detector measurements less than a few centimeters apart along a flat tissue volume, it is less obvious what methods can be used for transmittance through the larger tissue volumes typically associated with neonatal cerebral monitoring. In this study we compare the use of multiple distance frequency-domain measurements processed with (i) a modified Beer-Lambert law method, (ii) an analytic infinite-medium diffusion theory expression, and (iii) a numerical finite element solution of the diffusion equation, with the goal of recovering the absolute absorption coefficient of the medium. Based upon our observations, the modified Beer-Lambert method provides accurate absolute changes in the absorption coefficient, while analytic infinite-medium diffusion theory solutions or finite element-based numerical solutions can be used to calculate the absolute absorption coefficient, assuming that the data can be measured at multiple source-detector distances. We recommend that the infinite-medium multi-distance method or the finite element method be used across large tissue regions for calculation of the absolute absorption coefficient using frequency-domain near-infrared measurements at multiple positions along the head.

Absorption↗

Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography.

Near-infrared (NIR) diffuse tomography is emerging as a medical imaging modality for obtaining information related to tissue hemoglobin concentration and oxygen saturation and may be used for characterizing diseased tissues such as breast cancer. The optimal methodology for NIR image reconstruction remains an ongoing research problem with several new approaches being demonstrated in recent years. However, a comparison of reconstruction methods is problematic because tools for the objective assessment of image quality have yet to be clearly defined for this type of nonlinear reconstruction problem. Contrast-detail analysis has become an accepted assessment tool to quantify x-ray mammography image quality, and in this study it has been applied to a prototype NIR diffuse tomography system that is being evaluated for breast cancer characterization. The minimum detectable levels of contrast have been defined for different sizes of objects, and the minimum contrasts which can be accurately reconstructed have also been determined for the same object sizes. In general, objects 8 mm and larger in diameter can be accurately reconstructed and detected for most absorption contrasts which are observed in human tissues (i.e., greater than 1% contrast in absorption). Objects as small as 2 mm can be detected with high contrast (i.e., near 100%), but cannot be accurately reconstructed. Within the size range of 2 mm to 8 mm, there is an inverse correlation between contrast and detail size which is characteristic of the total noise in the system. This analysis provides an objective method for assessing detection and characterization limits and can be applied to future improvements in hardware system architecture as well as reconstruction algorithms.

Algorithms↗

Transient absorption changes in vivo during photodynamic therapy with pulsed-laser light.

High intensity pulsed-laser light can be used to excite absorbing molecules to transient states in large proportions. The laser-induced spectral changes can be characterized by transient changes in light propagation; through the tissue provided the excited states of these molecules have altered absorption spectra. Characterization of these transient changes may then be used to exploit new mechanisms in photosensitization and/or to optimize photobiological effects. In this study, transmittance and reflectance were measured as a function of laser pulse energy, from tissue-simulating media as well as in rat muscle and liver slices, both with and without the photosensitizer benzoporphyrin derivative monoacid (BPD-MA) present. There was a transient decrease in absorption from the photosensitizer at peak pulse irradiance in the range of 100-1000 W cm(-2). The depth of photodynamic treatment-induced tissue necrosis was measured in a subcutaneous prostate cancer model in Copenhagen rats. A comparison between continuous wave irradiation and pulsed irradiation with the same average incident irradiance showed no statistically significant difference in the depth of necrosis at 48 h after irradiation. These results indicate that photosensitizer population-state changes are measurable in tissues and may provide a method for measuring triplet-state properties of photosensitizer in vivo, but for BPD-MA at clinically used concentrations these changes do not significantly affect the depth of photodynamically-induced tissue damage.

Absorption↗

Confidence maps and confidence intervals for near infrared images in breast cancer.

This paper extends basic concepts of statistical hypothesis testing and confidence intervals to images generated by a new procedure for near infrared spectroscopic tomography being developed for use in breast cancer diagnosis. By estimating the covariance matrix of the pixels of an image from data used in the image reconstruction process, confidence maps for statistical tests on individual pixels and confidence intervals for entire images are displayed as an aid to research and clinical personnel interpreting possibly noisy images. The methods are applied to simulated and phantom-based images.

Breast Neoplasms↗

Photophysical properties of tin ethyl etiopurpurin I (SnET2) and tin octaethylbenzochlorin (SnOEBC) in solution and bound to albumin.

The photophysical characteristics of two second-generation PDT photosensitizers, tin ethyl etiopurpurin I (SnET2) and tin octaethylbenzochlorin (SnOEBC), have been measured in homogeneous solution and when bound to bovine serum albumin (BSA). The ground state and triplet state absorption spectra have been characterized, as have triplet lifetimes and quantum yields for intersystem crossing, singlet oxygen formation and photobleaching. In total, these parameters provide a complete set of data that can be used to quantitatively compare the photosensitizing efficiencies of these molecules. The photo-bleaching quantum yield of SnET2 is increased dramatically when it is bound to BSA, thus limiting the production of singlet oxygen at incident fluences above 1 J/cm2. In contrast, the quantum yield of photobleaching of SnOEBC is at least an order of magnitude lower than that of SnET2 under these conditions and does not significantly limit the photosensitization process for typical in vivo or in vitro fluences. This difference is expected to play a significant role in determining the relative photo-sensitizing ability of these compounds in vivo.

Animals↗

BOLD MRI vs. NIR spectrophotometry. Will the best technique come forward?

This paper will discuss the assumptions, strengths and weaknesses of both BOLD imaging and NIR spectrophotometry with respect to monitoring tissue oxygenation. BOLD, or blood oxygen level dependent MRI, is an imaging protocol that is sensitive to specific relaxation rates which are influenced by deoxyhemoglobin. NIRS is capable of providing information on oxyhemoglobin, deoxyhemoglobin and total hemoglobin. Both techniques have inherent assumptions, strengths and weaknesses. NIRS has not been able to provide the spatial sensitivity of BOLD. BOLD may be more difficult to quantify. Currently, these two methods are complementary, providing data that strengthens the interpretation of results from each modality. Recent data indicate that relaxation rates can be used to quantify deoxyhemoglobin in isolated blood and, under specific conditions, there is a strong correlation between deoxyhemoglobin content measured by NIRS and changes in relaxation rates measured by MRI. These data indicate that BOLD imaging has the potential to become an attractive alternative to NIRS.

Animals↗

A theoretical study of light fractionation and dose-rate effects in photodynamic therapy.

The efficacy of photodynamic therapy is dependent upon the optical dose rate or upon the fractionation schedule on the light. These effects are thought to be limited by the time required for oxygen diffusion from the capillaries, since this therapy can consume oxygen faster than it can be supplied to tissues distant from the blood vessels. Oxygen diffusion and consumption by metabolic and photochemical mechanisms have been modeled here to compare theoretical predictions with experimental results of varying light fractionations and delivered dose rates. The mathematics of the problem have been described in the literature, and the present study extends these calculations to allow a more direct and quantitative comparison with fractionation experiments, using both analytical and numerical arguments. The optimum fraction time was found to depend only on the intercapillary spacing and not on the intensity of irradiation or the concentration of photosensitizer. The calculations indicate that experimentally observed optimum fractionation times of 30 and 60 s correspond to a distance from capillary to cell of approximately 1 mm. These results suggest that the fractionated light irradiation experiments need careful interpretation, and some possible reasons for longer optimum fractionation times are discussed.

Dose-Response Relationship, Radiation↗

Initial assessment of a simple system for frequency domain diffuse optical tomography.

Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and phase (relative to each source) at 16 or 20 detectors on the surface of a 10 cm diameter cylinder. An iterative Newton-Raphson algorithm was used to estimate the absorption and scattering coefficients at each pixel in a 17 x 17 array minimizing the difference between measured and calculated values of the intensity and phase at the measurement sites. Forward calculations of the intensity and phase were based on a multigrid finite-difference solution of the frequency domain diffusion equation. Numerical simulations were used to examine the resolution, contrast, and accuracy of the reconstructions as well as the effects of measurement noise, systematic uncertainties in source-detector location, and accuracy of the initial estimates for the optical properties. Experimental tests also confirmed that the system could identify and locate both scattering and absorbing inhomogeneities in a tissue-simulating phantom.

Algorithms↗

Frequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory.

The goal of frequency-domain optical absorption spectroscopy is the non-invasive determination of the absorption coefficient of a specific tissue volume. Since this allows the concentration of endogenous and exogenous chromophores to be calculated, there is considerable potential for clinical application. The technique relies on the measurement of the phase and modulation of light, which is diffusely reflected or transmitted by the tissue when it is illuminated by an intensity-modulated source. A model of light propagation must then be used to deduce the absorption coefficient. For simplicity, it is usual to assume the tissue is either infinite in extent (for transmission measurements) or semi-infinite (for reflectance measurements). The goal of this paper is to examine the errors introduced by these assumptions when measurements are actually performed on finite volumes. Diffusion-theory calculations and experimental measurements were performed for slabs, cylinders and spheres with optical properties characteristic of soft tissues in the near infrared. The error in absorption coefficient is presented as a function of object size as a guideline to when the simple models may be used. For transmission measurements, the error is almost independent of the true absorption coefficient, which allows absolute changes in absorption to be measured accurately. The implications of these errors in absorption coefficient for two clinical problems--quantitation of an exogenous photosensitizer and measurement of haemoglobin oxygenation--are presented and discussed.

Algorithms↗