Publications and source records attributed to B W Reutter.

5 recordsLinked to original sources

Kinetic parameter estimation from SPECT cone-beam projection measurements.

Kinetic parameters are commonly estimated from dynamically acquired nuclear medicine data by first reconstructing a dynamic sequence of images and subsequently fitting the parameters to time-activity curves generated from regions of interest overlaid upon the image sequence. Biased estimates can result from images reconstructed using inconsistent projections of a time-varying distribution of radiopharmaceutical acquired by a rotating SPECT system. If the SPECT data are acquired using cone-beam collimators wherein the gantry rotates so that the focal point of the collimators always remains in a plane, additional biases can arise from images reconstructed using insufficient, as well as truncated, projection samples. To overcome these problems we have investigated the estimation of kinetic parameters directly from SPECT cone-beam projection data by modelling the data acquisition process. To accomplish this it was necessary to parametrize the spatial and temporal distribution of the radiopharmaceutical within the SPECT field of view. In a simulated chest image volume, kinetic parameters were estimated for simple one-compartment models for four myocardial regions of interest. Myocardial uptake and washout parameters estimated by conventional analysis of noiseless simulated cone-beam data had biases ranging between 3-26% and 0-28%, respectively. Parameters estimated directly from the noiseless projection data were unbiased as expected, since the model used for fitting was faithful to the simulation. Statistical uncertainties of parameter estimates for 10,000,000 events ranged between 0.2-9% for the uptake parameters and between 0.3-6% for the washout parameters.

Heart

Estimating glucose metabolism using glucose analogs and two tracer kinetic models in isolated rabbit heart.

The purpose of this investigation was to 1) evaluate the relative accuracy of the Sokoloff and Patlak tracer kinetic models in estimating glucose metabolic rate (GMR) in the presence and absence of insulin; 2) evaluate the effect of nutritional state on the lumped constant (LC); and 3) compare the kinetics of 2-fluoro-2-deoxy-D-[14C]glucose (FDG) and 2-deoxy-D-[3H]glucose (DG) membrane transport and phosphorylation. The experimental preparation was the isolated, red blood cell-albumin-perfused rabbit heart. Our results showed that both tracer kinetic models provided GMR estimates that correlated well with the Fick method (for FDG, R = 0. 84 and 0.91 for the Sokoloff and Patlak models, respectively); nutritional state did not affect the LC; and FDG and DG have different transport and/or phosphorylation parameters. We also observed that 1) the addition of a fourth compartment to the Sokoloff model reduced the mean squared error between measured and modeled data by a factor of 7.4; 2) a longer time (21.8 min) was required to obtain a linear phase of the Patlak plot than is allowed in clinical studies; and 3) accurate GMR estimates were obtained only by using different LCs reflecting insulin's presence or absence. Our results indicate potential sources of error in the use of FDG and positron emission tomography to quantify GMR in patients.

Animals

A methodology for specifying PET VOI's using multimodality techniques.

Volume-of-interest (VOI) extraction for radionuclide and anatomical measurements requires correct identification and delineation of the anatomical feature being studied. We have developed a toolset for specifying three-dimensional (3-D) VOI's on a multislice positron emission tomography (PET) dataset. The software is particularly suited for specifying cerebral cortex VOI's which represent a particular gyrus or deep brain structure. A registered 3-D magnetic resonance image (MRI) dataset is used to provide high-resolution anatomical information, both as oblique two-dimensional (2-D) sections and as volume renderings of a segmented cortical surface. VOI's are specified indirectly in two dimensions by drawing a stack of 2-D regions on the MRI data. The regions are tiled together to form closed triangular mesh surface models, which are subsequently transformed into the observation space of the PET scanner. Quantification by this method allows calculation of radionuclide activity in the VOI's, as well as their statistical uncertainties and correlations. The methodology for this type of analysis and validation results are presented.

Brain

Kinetic analysis of rubidium and thallium as deposited myocardial blood flow tracers in isolated rabbit heart.

Evaluation of myocardial perfusion with tracers such as thallium and rubidium is based on the assumption that tissue tracer content is proportional to flow. The purpose of this study was to evaluate the relationship between flow and tissue tracer content of 201Tl and 83Rb in the isolated perfused rabbit heart. 83Rb (86-day half-life), an isotope that is not used clinically, was used as a subsitute for 82Rb (76-s half-life) to improve the accuracy and precision of data acquisition. The multiple indicator-dilution technique was employed with two independent computational approaches. The first approach explicitly deconvolved 201Tl and 83Rb venous concentration curves by the intravascular reference tracer curve. The second approach used a conventional analysis. Both approaches showed that there was more early washout of 83Rb than 201Tl and that the heart retained 201Tl better than 83Rb within 2 min after isotope introduction. These data indicate that 201Tl is a better perfusion tracer than 83Rb in the isolated rabbit heart.

Animals

Strategies for extraction of quantitative data from volumetric dynamic cardiac positron emission tomography data.

The ability of positron emission tomography (PET) to serve as a useful myocardial perfusion indicator is well established. We describe a methodology for obtaining reliable quantitative kinetic parameters from dynamic cardiac PET data. Reconstructed images of the myocardium are subdivided into three-dimensional volumes of interest which are used to obtain quantitative measures of myocardial perfusion over physiologically meaningful anatomical regions. The quantitation technique rigorously models the uncertainty of estimated parameters while compensating for effects such as patient motion and partial volumes to arrive at model parameters with well-established confidence intervals.

Coronary Angiography