PubMed Health⌕ Search

Biomedical subjects

B W Smith

Publications and source records attributed to B W Smith.

At least 19 recordsLinked to original sources

Using physiological models and decision theory for selecting appropriate ventilator settings.

OBJECTIVE: To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS: Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side-effects of mechanical ventilation in a decision theoretic approach. Penalties are quantified for risk of lung barotrauma, acidosis or alkalosis, oxygen toxicity or absorption atelectasis, and hypoxaemia. RESULTS: The system is presented with an example of its use in a post-surgical patient. The mathematical models describe the patient's data, and the system suggests an optimal ventilator strategy in line with clinical practice. CONCLUSIONS: The system illustrates how mathematical models combined with decision theory can aid in the difficult compromises necessary when deciding on ventilator settings.

Carbon Dioxide↗

Radiative model of post-breakdown laser-induced plasma expanding into ambient gas.

The dynamics of the radiative plasma expansion into an ambient gas is considered. The model describes the evolution of the plasma emission spectrum and the dynamics of the resulting shock wave. The time frame for the applicability of the model is in the tens of nanoseconds after the laser pulse is terminated, until a few microseconds later when the plasma ceases to emit. It is assumed that local thermodynamic equilibrium is established and that the plume expands with spherical symmetry. The model outputs are spatial and temporal distributions of atoms, ions, and electron number densities, evolution of atom and ion line profiles, and the shock wave. The model should be applicable to spectroscopic analysis of the initial plasma state and plasma dynamics.

Journal Article↗

Microchip laser-induced breakdown spectroscopy: a preliminary feasibility investigation.

A commercial, 7 microJ/pulse, 550 ps microchip laser is used to induce plasma on Pb, Si, Cu, Fe, Ni, Ti, Zn, Ta, and Mo foils and a Si wafer. The measured plasma lifetime is comparable with the duration of the laser pulse (a few ns). The plasma continuum radiation is low, while some of the strong resonance lines (e.g., Zn 213.86 nm) show self-reversal. Quantitative analysis is possible using non-gated detectors but analytical lines should be chosen with care to avoid reduction in the linear dynamic range. The mass removed (0.5-20 ng/pulse) is sufficient to yield spectra that are detectable with portable grating spectrometers equipped with non-gated, non-intensified detector arrays. The spectrum of Cd is detected with a broadband portable spectrometer (200-950 nm). The combination of the broadband spectrometer and the microchip laser is very promising for material identification, especially in field applications.

Journal Article↗

Determination of the maximum temperature at the center of an optically thick laser-induced plasma using self-reversed spectral lines.

A method of temperature measurement based on the model developed by Bartels of an optically thick inhomogeneous plasma was applied to a laser plasma induced on a target containing barium. The method involves the intensity ratio measurement of two self-reversed Ba(II) lines. The temperature thus determined corresponds to the maximum temperature in the plasma center. The plasma temperature was measured for delay times between 0.5 micros and 10 micros in two spectrometer operating modes: the scanning mode and the dual-wavelength mode, the latter resulting in better precision. A detailed analysis of experimental errors was performed. The error strongly depended on the wavelength separation of the lines used. The most accurate results were obtained for the largest line separation. Using one line in the UV and the other in the visible region, the relative error was 2-6% for temperatures between 8000 K and 20 000 K. The distribution of the plasma temperature along the plasma height was measured in the same delay time range. The temperature was found to be uniform along the plasma vertical axis, thus confirming the plasma cylindrical symmetry.

Journal Article↗

Automatic correction of continuum background in laser-induced breakdown and Raman spectrometry.

The goal of this work was the development and evaluation of an algorithm for the approximation and automatic subtraction of continuum backgrounds in laser-induced breakdown and Raman spectra. The background correction algorithm was applied to simple and complex spectra and its effect on identification accuracy was studied. Linear correlation was used for the identification of plastic samples using both laser-induced breakdown and Raman spectra. For both techniques, the algorithm successfully eliminated continuum background without compromising spectral integrity. A significant improvement in the percentage of correct plastic identifications was observed for Raman spectra. The approach should be applicable to a wide range of background correction problems in atomic and molecular spectroscopy.

Algorithms↗

Laser-enhanced ionization with avalanche amplification: detection of cesium at fg/mL levels.

The avalanche amplification of the laser-enhanced ionization signal of Cs atoms in a flame has been studied. Ionization of Cs atoms, enhanced by two-step excitation, was detected in hydrogen and propane flames. By employing the effect of avalanche amplification of electrons, high signal-to-noise ratio (approximately 10(4)) was obtained for a 100 ppt Cs solution. The extrapolated limit of detection was 30 fg/mL (ppq).

Cesium↗

Mapping the one-dimensional electronic States of nanotube peapod structures.

Arrays of C60 molecules nested inside single-walled nanotubes represent a class of nanoscale materials having tunable properties. We report electronic measurements of this system made with a scanning tunneling microscope and demonstrate that the encapsulated C60 molecules modify the local electronic structure of the nanotube. Our measurements and calculations also show that a periodic array of C60 molecules gives rise to a hybrid electronic band, which derives its character from both the nanotube states and the C60 molecular orbitals.

Journal Article↗

A comparison of leg-to-leg bioelectrical impedance and skinfolds in assessing body fat in collegiate wrestlers.

A comparison of the leg-to-leg bioelectrical impedance (BIA) system and skinfold analysis in estimating % body fat in a large number of National Collegiate Athletic Association (NCAA) collegiate wrestlers was conducted. A series of 5 cross-sectional assessments, including the NCAA Division I and III Championships, were completed throughout the 1998-1999 wrestling season with samples ranging from (N = 90-274). Body density was determined from the 3 skinfold measures using the Lohman prediction equation. BIA measurements were determined using the Tanita body fat analyzer, model 305. Significant correlations between methods ranging from (r = 0.67-0.83, p < 0.001) and low standard error of estimates (SEE) for % body fat ranging from 2.1-3.5% were found throughout the 5 assessment periods. This preliminary study demonstrated that the leg-to-leg bioelectrical impedance system accurately estimated % body fat when compared to skinfolds in a diverse collegiate wrestling population.

Adolescent↗

Increased discrimination of "false memories" in autism spectrum disorder.

Individuals with autism spectrum disorder (ASD) have impaired ability to use context, which may manifest as alterations of relatedness within the semantic network. However, impairment in context use may be more difficult to detect in high-functioning adults with ASD. To test context use in this population, we examined the influence of context on memory by using the "false memory" test. In the false memory task, lists of words were presented to high-functioning subjects with ASD and matched controls. Each list consists of words highly related to an index word not on the list. Subjects are then given a recognition test. Positive responses to the index words represent false memories. We found that individuals with ASD are able to discriminate false memory items from true items significantly better than are control subjects. Memory in patients with ASD may be more accurate than in normal individuals under certain conditions. These results also suggest that semantic representations comprise a less distributed network in high-functioning adults with ASD. Furthermore, these results may be related to the unusually high memory capacities found in some individuals with ASD. Research directed at defining the range of tasks performed superiorly by high-functioning individuals with ASD will be important for optimal vocational rehabilitation.

Adult↗

Psychosocial resource loss as a mediator of the effects of flood exposure on psychological distress and physical symptoms.

This study used the Conservation of Resources stress model to examine the role of psychosocial resource loss in the aftermath of Midwest flooding. Questionnaires were distributed through churches and completed by 131 adults in flood-affected communities 6 weeks and 6 months after the flood's crest. Frequent psychosocial losses included losses of routine, sense of control, sense of optimism, accomplishing goals, and time with loved ones. Path analysis revealed that psychosocial resource loss mediated the effects of flood exposure on both psychological distress and physical symptoms at 6 months post-flood. The findings suggest that interventions designed to prevent psychosocial resource loss may reduce the long-term effects of disasters.

Adaptation, Psychological↗

Creatine supplement use in an NCAA Division I athletic program.

OBJECTIVE: To determine the prevalence and pattern of creatine use among varsity athletes at a National Collegiate Athletic Association (NCAA) Division I athletic program. DESIGN: Anonymous descriptive survey. SETTING: Institutional. PARTICIPANTS: Collegiate varsity and junior varsity athletes. MAIN OUTCOME MEASURES: Self-reports of creatine use, including pattern of use and dose, source of information on creatine, and expected and perceived effects from creatine use. RESULTS: Surveys were obtained from 93% of 806 eligible athletes. Overall, 68% of athletes had heard of creatine and 28% reported using it. Forty-eight percent of men reported having used creatine as compared with 4% of women. With two exceptions, all men's teams had at least 30% of athletes who reported a history of creatine use. Of athletes that had used creatine, about one-third had first used it in high school. Friends and teammates were the most common sources of creatine information. Increased strength and muscle size were the most common effects the athletes expected and perceived from creatine use. CONCLUSION: In this population of collegiate athletes, creatine use was widespread among men but was minimal among women. Athletes learned about creatine supplementation primarily from their peers, and substantial numbers began to take creatine while still in high school. Most athletes could not report their dosing of creatine. This study reported findings at one location for one academic year. Studies are needed at multiple locations and over time to further delineate creatine use patterns.

Adolescent↗

Pharmacologic treatment of exercise-induced asthma.

Exercise-induced asthma (EIA) is a complex disorder affecting a sizeable minority of athletes. Proper pharmacologic management allows most every athlete at any level to participate with EIA. This article briefly addresses the pathophysiology, diagnosis, and basic treatment principles, including nonpharmacologic management for EIA. Most of the article details the current treatment strategies and provides information on experimental treatments being investigated. In addition, ergogenic concerns and problems in treating elite athletes are discussed.

Administration, Inhalation↗

Delayed sequelae after acute overdoses or poisonings: cranial neuropathy related to ethylene glycol ingestion.

A 31-year-old woman came to the hospital with breathlessness, confusion, and a refractory anion gap metabolic acidosis; acute renal failure subsequently developed. Her blood ethylene glycol concentration was 390 mg/L, and she was treated with an intravenous ethanol infusion and hemodialysis. During the tenth and eleventh day after admission bilateral seventh cranial nerve paralysis developed, as well as bilateral dysfunction of cranial nerves II, V, VIII, IX, X and XII. Magnetic resonance imaging of her head showed gadolinium enhancement of the fifth cranial nerve bilaterally and a communicating hydrocephalus. Over the subsequent 11 months she recovered full function of her cranial nerves V, VII, IX, X, and XII, and she had subjective clinical improvement to baseline function in cranial nerves II and VIII. This case serves to introduce a discussion of agents that cause delayed complications after their acute toxic ingestion.

Adult↗

Ultratrace determination of lead in whole blood using electrothermal atomization laser-excited atomic fluorescence spectrometry.

Laser-excited atomic fluorescence has been used to detect lead that was electrothermally atomized from whole blood in a graphite furnace. A 9 kHz repetition rate copper vapor laser pumped dye laser was used to excite the lead at 283.3 nm, and the resulting atomic fluorescence was detected at 405.8 nm. No matrix modification was used other than a 1:21 dilution of the whole blood with high-purity water. Using the atomic fluorescence peak area as the analytical measure and a background correction technique based upon a simultaneous measurement of the transmitted laser intensity, excellent agreement for NIST and CDC certified whole blood reference samples was obtained with aqueous standards. A limit of detection in blood of 10 fg/mL (100 ag absolute) was achieved.

Calibration↗

Microsecond-pulse glow discharge atomic emission.

A microsecond pulsed glow discharge was produced with high pulse magnitude and small duty cycle. Time resolved emission and absorption spectroscopy was applied to study the processes of atomization, excitation and ionization in the glow discharge. Experimental results show that, without overheating the sample, the emission peak intensity is several orders greater than that obtained in the conventional dc mode. This implies that a much more intense plasma is generated during pulsed "on" region.

Journal Article↗

Acute knee injuries: Part I. History and physical examination.

A thorough history and physical examination are helpful in the diagnosis of meniscal damage, cruciate and collateral ligament sprains and patellar instability, the four major acute knee injuries. When performing a physical examination in a patient with a knee injury, the uninjured knee should always be assessed first and used for comparison. Examination includes passive and active range-of-motion testing, palpation of the joint line spaces, and a variety of maneuvers to evaluate knee stability. Valgus and varus testing provides assessment of the collateral ligaments. The Lachman and pivot shift tests are useful in the evaluation of the anterior cruciate ligament. The posterior drawer and tibial sag tests are used to evaluate the posterior cruciate ligament. The bounce test, McMurray's test and Apley's grind test can aid in the diagnosis of meniscal injury.

Humans↗