PubMed Health⌕ Search

Biomedical subjects

B Wall

Publications and source records attributed to B Wall.

30 records · Page 2Linked to original sources

Low-dose methotrexate compared with auranofin in adult rheumatoid arthritis. A thirty-six-week, double-blind trial.

Weekly treatment with low-dose oral methotrexate (MTX) was compared with daily auranofin (AUR) treatment in a 36-week double-blind, randomized, multicenter study of 281 patients with active, adult-onset rheumatoid arthritis. Both treatment groups showed significant improvement by the usual measures of clinical efficacy. The response with MTX occurred earlier and was consistently greater than that with AUR. An intent-to-treat analysis showed significantly greater improvement (P less than 0.01) with MTX for painful and swollen joint counts and physician and patient global assessments of disease activity. Adverse reactions were reported more frequently in the AUR group, and more AUR-treated patients were withdrawn from the study because of toxicity. MTX was thus more effective and better tolerated than AUR in this study.

Administration, Oral↗

Pharmacokinetics and hemodynamic and diuretic/natriuretic effects of felodipine administered as an extended-release tablet.

In this study the pharmacokinetics, and the hemodynamic and diuretic/natriuretic effects of three different doses of felodipine ER-10, 20, and 40 mg--were evaluated in healthy subjects. There was a linear correlation between the dose of felodipine, Cmax, and AUC24, showing that the absorption was linearly related to the dose. The diastolic blood pressure was reduced by 15-20% after the two highest doses. The maximal blood-pressure lowering effect was seen 4 hours after drug intake, and a small reduction in diastolic blood pressure was still present after 24 hours. This was, however, not statistically significant but was related to a sustained effective plasma concentration of the drug (6 nmol/l). Systolic blood pressure was not affected. The two highest doses of felodipine ER produced a significant increase in heart rate 2 and 6 hours after the dose, compared with placebo. There was also a significant decrease in forearm vascular resistance after the 20- and 40-mg doses. Both diuresis and natriuresis were significantly increased by about 100% each during the first 4 hours after the 20-mg dose. Following the 40-mg dose, diuresis and natriuresis were lower than after 20 mg and were not significantly different from placebo.

Administration, Oral↗

A clonal analysis of Neisseria meningitidis serogroup A.

A typing scheme has recently been developed for Neisseria meningitidis serogroup A based on the clonal population structure of these bacteria. An international strain collection consisting of 423 group A strains isolated from 23 epidemics or outbreaks since 1963, as well as from older epidemics and numerous non-epidemic situations was used in the analysis. Strains were first segregated into electrophoretic types, depending on the combined score for the electrophoretic mobilities of 7 cytoplasmic isoenzymes resolved by starch gel electrophoresis and of 2 outer membrane proteins resolved by sodium dodecyl sulphate polyacrylamide gel electrophoresis. The bacteria were subsequently assigned to one of 21 clones after numerical analysis of their electrophoretic types. The epidemiological value of the typing scheme was assessed by examining case and carrier strains isolated during (1982-83) and subsequent to (1984-85) an epidemic in the Gambia, West Africa. The case isolates, all of which were serogroup A, were of a single clonal type. All serogroup A carrier isolates were also of this clone, while carrier strains of other serogroups showed greater clonal diversity. These results indicate that case strains during an epidemic show little clonal diversity and thus that the typing scheme is of value in distinguishing the etiology of epidemics. A retrospective epidemiological analysis of the strains in the international collection showed that most serogroup A epidemics were associated with a single or predominant clone, although some epidemics were of mixed etiology.(ABSTRACT TRUNCATED AT 250 WORDS)

Africa↗

Massive hemorrhage from a lumbar artery following percutaneous renal biopsy.

We report a case of severe lumbar artery bleeding following percutaneous renal biopsy. A 68-year-old man with a history of rheumatoid arthritis, gold therapy, and Staphylococcus aureus bacteremia underwent a percutaneous renal biopsy to evaluate nephrotic syndrome and renal insufficiency. Following the procedure, he developed signs of severe hemorrhage. A selective renal angiogram revealed an intrarenal bleeding site that was occluded by selective embolization. The patient failed to stabilize however, and repeat angiography was performed two days later. A lumbar artery was identified as a second bleeding site, and was also occluded by selective embolization. The bleeding was controlled, but the patient developed serious complications and died five days later.

Aged↗

Reliable estimation of hemoglobin A2 concentration by electrophoresis with densitometry.

Elevated hemoglobin A2 (Hb A2) levels can be identified conveniently by densitometry after electrophoresis on cellulose acetate strips. Because a recent report questioned the accuracy of this technic, the method was re-evaluated by paired comparison with microcolumn chromatography. Analysis of 100 patient specimens showed high correlation (r = +0.84), but an average Hb A2 concentration 0.7% higher by densitometry than by chromatography (P less than 0.001). With upper limits set at 4.5%, and 3.8%, respectively, results were divided into "normal" and "high" for each method. Concordant results were obtained in 97 of the 100 cases (82 normal, 15 high). Another densitometer of improved design was used for paired analysis of 50 additional specimens, 25 normal and 25 with beta-thalassemia trait. The two groups were well separated by both procedures, and Hb A2 levels were similar (r = +0.92, P greater than 0.6). This study demonstrates that it is possible, with carefully controlled technics and properly calibrated instruments, to use electrophoresis with densitometry as a reliable means of identifying abnormal Hb A2 levels.

Child↗

Default patterns of patients attending clinics for sexually transmitted diseases.

The influence of gender, propaganda, and treatment methods was studied in relation to default behaviour of patients with sexually transmitted diseases. The overall default rate of men and women was similar, but a larger proportion of men defaulted after the initial visit, while the biggest fall-out in women was after the second attendance at the clinic. The institution of a propaganda campaign was followed by a reduction in defaulting. The statistical significance of this is open to question, however: moreover the observed improvement in default rate was not maintained once the propaganda had been relaxed. Men treated for non-gonococcal urethritis by a regimen which included one injection a week for three weeks showed a highly significantly lower default rate compared with those who received tablets alone.

Counseling↗

Electronic platelet counts with the Coulter counter. Reassessment of a correction factor.

Platelet counts are determined on the Coulter electronic counter by counting the diluted platelet-rich plasma obtained by sedimentation or centrifugation of whole blood. In calculating the whole-blood platelet count, an empirical correction factor for platelet-free plasma trapped by sedimented erythrocytes has been recommended, and a widely-distributed circular slide rule calculator incorporates the correction factor. In this study, visual and electronic platelet counts were compared in 100 specimens with counts ranging from 10 to 1,100 X 10(3) per mul and hematocrits ranging from 17.5 to 48.5%. Platelet-rich plasma samples prepared by a centrifugation method (Plateletfuge) gave machine counts in close agreement with those of samples prepared by sedimentation. Whole-blood platelet counts determined with the circular calculator were consistently lower than visual counts, with an average difference of -17%. The electronic counts were recalculated after elimination of the correction factor, and agreement then improved to an average difference of only +1.6%. The correction factor for trapped platelet-free plasma leads to erroneously low values and should not be used.

Blood Cell Count↗