Biodegradation of polyether polyurethane inner insulation in bipolar pacemaker leads.

Several bipolar coaxial pacemaker leads, composed of an outer silicone rubber insulation and an inner polyether polyurethane (PEU) insulation, which were explanted due to clinical evidence of electrical dysfunction, were analyzed in this study. Optical microscopy (OM) and scanning electron microscopy (SEM) were used to determine the cause of failure. Attenuated total reflectance-Fourier transform infrared microscopy (ATR-FTIR) was used to analyze the PEU insulation for chemical degradation. In all leads, the silicone rubber outer insulation showed no signs of physical damage. Physical damage to the inner PEU insulation was the source of electrical dysfunction. Cracks through the PEU compromised the insulation between the inner and outer conductor coils in the lead. It was observed with SEM that these cracks originated on the outer surface of the inner insulation and progressed inward. ATR-FTIR analysis showed that the PEU had chemically degraded via oxidation of the ether soft segment. Furthermore, it was revealed that chemical degradation was more advanced on the outer surface of the PEU. It was hypothesized that hydrogen peroxide permeated through the outer silicone insulation and decomposed into hydroxyl radicals that caused the chemical degradation of PEU. The metal in the outer conductor coil catalyzed the decomposition of the hydrogen peroxide. Chemical degradation of the PEU could also have been catalyzed by metal ions created from the corrosion of the metal in the outer conductor coil by hydrogen peroxide. Physical damage probably occurred in regions of the leads that were subjected to a higher hydrogen peroxide concentration from inflammatory cells and high degrees and rates of strain due to intercorporeal movement, including, but not limited to, cardiac movement. Chemical degradation and physical damage probably had a synergistic affect on failure of the insulation, in that as chemical degradation proceeded, the polymer surface became brittle and more susceptible to physical damage. As physical damage proceeded, cracks propagated into the unaffected bulk, exposing it to oxidants.

Biocompatible Materials↗

Lead- and device-related complications in the antiarrhythmics versus implantable defibrillators trial.

BACKGROUND: Implantation of transvenous implantable cardioverter defibrillators (ICDs) by use of a nonthoracotomy approach has become routine therapy for survivors of life-threatening tachyarrhythmias. The purpose of this study was to identify and prospectively characterize the frequency of lead- and ICD-related complications from the Antiarrhythmics versus Implantable Defibrillators (AVID) Trial. METHODS AND RESULTS: Between June 1, 1993, and April 7, 1997, 539 patients received nonthoracotomy ICDs either as initial treatment assignment (477) or as crossover from medical management (62). A total of 62 first complications occurred. The subclavian route of insertion resulted in more complications than the cephalic vein route, 46 of 339 (14%) versus 6 of 135 (4%), P = .005, as did the abdominal versus pectoral generator site, 31 of 238 (13%) versus 17 of 291 (6%), P<.02. Most dislodgements and system infections tended to occur in the 3 months after implantation, whereas lead fractures continued to occur throughout follow-up. Failure to use perioperative antibiotics was a predictor of system infection (P = .001). CONCLUSIONS: These data suggest that cephalic vein access and pectoral generator site may result in fewer complications. The continued occurrence of lead fractures and the need for premature system revision supports the practice of close routine ICD system surveillance.

Anti-Arrhythmia Agents↗

The management of surgical complications of pacemaker and implantable cardioverter-defibrillators.

The rate of implantation of pacemakers and implantable cardioverter-defibrillators (ICDs) is ever-increasing. The relative ease of device implantation utilizing a relatively simple, expeditious, percutaneous approach, without the requirement for general anesthesia or long recuperation times, has fueled enthusiasm for implantation. However, the complication risk is ever-present and forms the subject of this pragmatic review, which is limited to the management of only the surgical complications of device implantation. The management of surgical complications related to the implantation of pacemakers and ICDs should include (1) awareness of potential complications, (2) a meticulous approach to the implantation procedure to avoid complications, (3) approach to diagnosis and (4) specific therapy. With a clear understanding of the accepted implant indications and potential complications, and a meticulous approach to the implant and post implant follow up, the incidence of complications can be minimized.

Defibrillators, Implantable↗

The Ablate and Pace Trial: a prospective study of catheter ablation of the AV conduction system and permanent pacemaker implantation for treatment of atrial fibrillation. APT Investigators.

BACKGROUND: The Ablate and Pace Trial (APT) prospectively assessed the effects of catheter ablation of the AV conduction system and permanent pacemaker implantation on health-related quality of life, survival, exercise capacity, and ventricular function in 156 patients with symptomatic atrial fibrillation. METHODS: All patients referred for catheter ablation and permanent pacemaker implantation because of medically-refractory atrial fibrillation at 16 centers were screened for enrollment in a prospective registry. Baseline assessment prior to ablation included measurement of quality of life, including the Health Status Questionnaire, the Quality of Life Index and the Symptom Checklist: Frequency and Severity. Exercise capacity was assessed with metabolic treadmill exercise testing and ventricular function was quantitated with echocardiography. The quality of life instruments, exercise capacity, and echocardiography were repeated at 3 and 12 months after catheter ablation. RESULTS: The APT population included 90 men and 66 women (66.1 +/- 11.5 years of age) with either chronic (n = 70), recurrent (n = 31), or paroxysmal atrial fibrillation (n = 55). Structural heart disease was present in 78.2% of patients. Successful ablation of AV conduction was achieved in 155 of 156 patients (99.4%). Survival at 1 year was 85.3%, with 5 of 23 deaths being sudden cardiac deaths. Survival over the first year of follow-up was significantly lower for patients with a baseline left ventricular ejection fraction (LVEF) < 0.45 (0.73) than for patients with a LVEF > or = 0.45 (0.88, p = 0.03). The NYHA functional class improved from 2.1 at baseline to 1.8 at 3 months and 1.9 at 12 months of followup (p = 0.0001). Significant improvement in quality of life scores were noted for all 8 subscales of the Health Status Questionnaire, for the overall rating of the Quality of Life Index, the Health and Function subscales; Arrhythmia-related symptoms were markedly reduced as measured by the Symptom Checklist: Frequency and Severity scale. The mean LVEF improved from 0.50 +/- 0.20 at baseline to 0.54 +/- 0.20 at 3 months (p = 0.03). The LVEF 12 months after ablation was 0.52 +/- 0.20, not statistically different from baseline. Individuals with reduced systolic function at baseline had the greatest improvement, from LVEF 0.31 +/- 0.20 at baseline to 0.41 +/- 0.20 at 3 months and 0.41 +/- 0.30 at 12 months (p = 0.0001). There were no significant changes in treadmill exercise duration (10.0 +/- 4.3 min at baseline and 11.6 +/- 3.6 min at 12 months) or VO2max (1467 +/- 681 ml O2 min baseline and 1629 +/- 739 ml O2 min at 12 months). CONCLUSIONS: Catheter ablation of the AV conduction system and permanent pacemaker implantation were associated with improved quality of life and left ventricular function in this population of highly symptomatic patients with atrial fibrillation refractory to medical therapy.

Aged↗

Iridium oxide-coated defibrillation electrode: reduced shock polarization and improved defibrillation efficacy.

BACKGROUND: Transvenous implantable cardioverter-defibrillator (ICD) leads are designed to deliver electric shocks to the heart for termination of ventricular dysrhythmias. However, the efficiency of different lead materials has not been well studied. This study compares an ICD lead coated with iridium oxide (IROX), a material that reduces shock-induced polarization, with an otherwise identical, uncoated lead. METHODS AND RESULTS: The defibrillation threshold (DFT) was determined in 13 swine with both IROX-coated and uncoated ICD leads paired with an uncoated "can" electrode. The leads were exchanged through a Teflon sheath to reproduce the intracardiac position. The delivered energy DFT of the IROX-coated lead was 15.9+/-5.4 J and was significantly lower than the delivered energy DFT of the uncoated lead (19.1+/-5.1 J; P<.006). The initial lead impedance was equivalent in both leads (IROX, 41.7+/-5.8 omega; uncoated, 41.3+/-4.7 omega; P=NS) at DFT. However, the impedance rose by 7.3+/-2.0 omega during the first phase and by 3.7+/-2 omega during the second phase with the uncoated lead, whereas the corresponding impedance change was 1.0+/-0.3 omega during phase 1 and 1.6+/-0.5 omega during phase 2 (P<.01 each phase) when the IROX-coated lead was used. CONCLUSIONS: This study shows that an IROX coating of this lead system significantly lowers the DFT energy in the swine model. The blunting of the impedance rise by the IROX coating that is seen is consistent with a reduction in electrode polarization.

Animals↗

Comparison of clinical characteristics and frequency of implantable defibrillator use between randomized patients in the Antiarrhythmics Vs Implantable Defibrillators (AVID) trial and nonrandomized registry patients.

In the Antiarrhythmics Vs Implantable Defibrillators (AVID) trial, all patients who meet the study entry criteria are followed in a registry. During the period between June 1993 and June 1995, of 1,117 patients who were enrolled in the registry and met the study entry criteria, 476 were randomized to receive either implantable cardioverter-defibrillators (ICDs) or drug therapy (amiodarone or sotalol), and 641 patients were not randomized for a variety of reasons including: patient refusal (42%); physician refusal (43%); concerns about ability to maintain follow-up over several years (10%), and others (6%). There were no significant differences between the 476 randomized and 641 nonrandomized patients with regard to clinical characteristics, left ventricular function, history of congestive heart failure, medical history, and previous cardiac procedures performed before the index event, except that randomized patients were slightly older (65 vs 62 years) and had a slightly higher prevalence of coronary artery disease and previous myocardial infarction. The index event and location of the index event were not significantly different between the 2 groups. Although 14% of registry patients received neither ICD nor antiarrhythmic drug therapy, ICDs were no more frequently used in the registry patient than antiarrhythmic drugs (45% for ICD vs 42% for drugs). Thus, randomized AVID patients have very similar clinical characteristics, cardiac history, and presenting arrhythmias as to nonrandomized eligible patients. Therefore, the results of the AVID trial may be generalized for all patients with AVID-eligible arrhythmias.

Adolescent↗

Effect of atrioventricular synchrony on stroke volume during ventricular tachycardia in man.

The hemodynamic consequences of atrioventricular (AV) synchrony during ventricular tachycardia were evaluated during cardiac electrophysiologic testing. The relationship between stroke volume and the AV interval was investigated on a beat-by-beat basis in six patients during induced monomorphic ventricular tachycardia. Stroke volume was calculated either (1) in the right ventricle using impedance catheter method (four patients) or (2) in the left ventricle using Doppler measurement of aortic blood velocity (two patients). The impedance catheter method underestimated stroke volume by a factor of 4.2 +/- 2.4 compared with the thermodilution cardiac output method. However, there was a highly linear relationship between both methods for computing stroke volume (r greater than 0.9). Five patients had complete AV dissociation during ventricular tachycardia, and different AV intervals spanned the entire tachycardia cycle lengths. Largest stroke volumes were associated with optimal AV intervals within 120 and 230 msec, resulting in a 97 +/- 59% increase in stroke volume over ventricular tachycardia cycles not associated with atrial activity. Customized atrial pacing during ventricular tachycardia may provide a valuable means for artificially establishing the hemodynamically optimal AV interval and eliminating the ventricular tachycardia cycles not preceded by atrial activity.

Atrioventricular Node↗

Pacing lead survival: performance of different models.

UNLABELLED: Recent reports have shown poor survival of some leads currently in use. Long-term survival analysis of 2,444 leads (1,059 atrial and 1,385 ventricular) implanted in this institution since January 1980, and having at least 1 month of follow-up was performed. The survival of 123 different models was compared with the average survival of all the leads implanted in the corresponding chamber. Failure was defined as inactivation of the lead (electrical abandonment, explant, or cap) due to insulator and/or conductor fracture. RESULTS: The mean follow-up was 33 +/- 32 months. The cumulative survival for different atrial lead models was consistent with the average performance in the atrium. No atrial lead showed better or worse survival compared to the others. In the ventricular group, the Medtronic 4012 lead showed statistically significant poorer survival (P = 0.01) compared with the average survival of the ventricular leads. The Cardiac Pacemakers, Inc. (CPI) 4010 lead showed a nonsignificant (P = 0.12) worse performance than the average for ventricular leads. CONCLUSIONS: (1) The Medtronic 4012 had a significantly poorer performance than the rest of the leads. A trend in similar direction was found for the CPI 4010, also in the ventricular group; (2) Atrial lead models showed a stable survival; and (3) Frequent follow-up is required for some leads, especially in pacemaker dependent patients.

Actuarial Analysis↗

Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardial and submuscular patch system.

The automatic cardioverter-defibrillator lead system is implanted by a thoracotomy procedure that may result in atelectasis, pleural effusion, cardiac tamponade and lengthy convalescence. A new defibrillator lead system that allows selection of different defibrillating current pathways is implanted without a thoracotomy. Ten patients requiring a cardioverter-defibrillator for recurrent sustained ventricular tachycardia (five patients) or aborted sudden cardiac death (five patients) were evaluated for implantation of this lead system. A lead configuration with a bidirectional defibrillating current pathway was implanted in nine patients. The defibrillation threshold with this lead configuration was 15 J in five patients, 20 J in three and 30 to 35 J in one patient. In the remaining patient the lead system had a 40 J defibrillation threshold and was not implanted. No perioperative complications occurred. Induced ventricular fibrillation was successfully terminated at the predischarge and intermediate follow-up (8 to 12 weeks) electrophysiologic studies. During the follow-up period, there were three deaths (one sudden, two due to heart failure) and two lead system failures (oversensing with inappropriate shocks in one patient and patch lead fracture in another). Implantation of the cardioverter-defibrillator lead system by a nonthoracotomy approach is feasible, has no significant perioperative complications and is well tolerated by patients. Effective defibrillation was demonstrated immediately as well as at intermediate follow-up study. The occurrence of patch lead fracture and oversensing requires improvement in the present (nonthoracotomy) lead system technology.

Cardiac Pacing, Artificial↗

Clinical performance of the implantable cardioverter defibrillator: electrocardiographic documentation of 101 spontaneous discharges.

Records of 105 patients, who received an automatic implantable cardioverter defibrillator (AICD), were studied to investigate the causes of spontaneous AICD discharges and to correlate the symptoms with the arrhythmias triggering AICD discharges. During a follow-up period of 13 +/- 8 months, 46/105 (44%) patients had 566 spontaneous AICD discharges. A total of 101 discharges were documented with Holter monitoring in 23 patients. In this study group, there were 8 (8%) AICD discharges for 5 episodes of ventricular fibrillation, and 68 (67%) discharges for 63 episodes of sustained ventricular tachycardia. Patients lost consciousness in all episodes of ventricular fibrillation, but were symptomatic prior to only 36 (53%) discharges in ventricular tachycardia. Nonsustained ventricular tachycardia persisting for a period of 7.5 +/- 2 seconds resulted in 20 AICD discharges; patients were symptomatic prior to 13 (65%) discharges. Supraventricular tachycardias triggered three discharges. One patient had two spurious discharges during sinus rhythm. In conclusion, most of the spontaneous AICD discharges were appropriate for the detected rhythms, but only clinically appropriate for the management of arrhythmias in 75% of the cases. A significant portion of the patients with sustained or nonsustained ventricular tachycardias triggering AICD discharges were asymptomatic prior to discharge, which requires further assessment of the physiology of the arrhythmia as a component of the detection algorithm.

Electric Countershock↗

The effects of percutaneous catheter ablation on preexisting permanent pacemakers.

STUDY OBJECTIVE: Determine the effect of percutaneous catheter ablation (CA) on permanent pacemakers. MEASUREMENTS AND RESULTS: Twenty-three patients who underwent CA at The Cleveland Clinic Foundation from September 1983 to January 1990, and had a previously implanted pacemaker were studied. Electrocardiographic data during the CA procedure and clinic data including pacemaker evaluations were analyzed. Fifty-two percent (12/23) of the pacemakers malfunctioned: five developed transient ventricular loss of capture; two undersensing; one oversensing; three could not be interrogated or programmed, and one did not respond to the magnet test. Four patients developed syncopal episodes and two severe dizziness after the procedure. All had their pacemakers replaced. In total, seven were explanted. Destructive analysis by the individual manufacturer identified pacemaker circuitry failure in five. Unipolar pacemakers and anodal ablation procedures had more frequent and severe malfunctions, but the difference was not statistically significant. CONCLUSIONS: Pacemaker malfunction is frequent during CA. It may be prevented by programming the pacemaker, when possible, to the nonfunctioning mode (000 mode). Temporarily disconnecting the pacemaker during ablation requires further evaluation as an alternative approach. Close follow-up can detect pacemaker malfunction and prevent complications.

Adult↗

Pacemaker and defibrillator combination therapy for recurrent ventricular tachycardia.

The judicious use of antitachycardia pacemakers can enhance the benefits of automatic implantable cardioverter defibrillators in certain patients. Both devices were implanted in 10 highly selected patients with drug-refractory pace-terminable sustained ventricular tachycardia. During the observation period of 8 +/- 4.8 months, the automatic pacemakers detected 1,542 episodes of ventricular tachycardia and appropriately managed 1,373. The automatic implantable defibrillator was activated at least once in every patient; on two documented occasions, the defibrillator discharged because the automatic pacemaker accelerated the tachycardia. Concomitant antiarrhythmic drugs could be reduced but not withdrawn. With meticulous device programming and testing, the two systems in combination can work synergistically to manage malignant ventricular arrhythmias in carefully selected patients.

Aged↗

Continuous right ventricular volume assessment by catheter measurement of impedance for antitachycardia system control.

Current implantable defibrillators are unable to differentiate between hemodynamically stable and unstable arrhythmias. This may result in unnecessary high energy shocks during arrhythmias that are better managed with other interventions. This study assessed the efficacy of the impedance catheter in sensing relative volumetric changes in the right ventricle as a measure of the hemodynamic status during an arrhythmia. During electrophysiological testing, 37 arrhythmias were induced in 12 patients aged 28-74 years. Rhythms recorded were: (A) hemodynamically stable tachyarrhythmias (supraventricular tachycardia and sustained monomorphic ventricular tachycardia)--21 episodes; and (B) hemodynamically unstable ventricular arrhythmias causing syncope (hypotensive ventricular tachycardia and ventricular fibrillation)--16 episodes. During unstable arrhythmias, stroke impedance (32 +/- 17%), arterial systolic pressure (40 +/- 11%), and right ventricular pulse pressure (15 +/- 20%), expressed as percentages of corresponding sinus rhythm values, were significantly lower than in stable arrhythmias (84 +/- 26%, 72 +/- 8%, and 111 +/- 37%, respectively); P less than 0.001. There was a good correlation between stroke impedance and mean arterial pressure during arrhythmia (r = 0.84). Impedance sensing is a practical method for distinguishing between hemodynamically stable and unstable arrhythmias. Implementation of hemodynamic sensing into the algorithm of future antitachycardia systems may improve the management of arrhythmias by adding options for selective pace termination or cardioversion.

Adult↗

Effects of extracorporeal shock wave lithotripsy on cardiac pacemakers and its safety in patients with implanted cardiac pacemakers.

UNLABELLED: Effects of extracorporeal shock wave lithotripsy (ESWL) were studied on 15 pacemakers (standard single chamber n = 5, dual chamber n = 6, rate responsive single chamber [Activitrax] n = 4). In-vitro testing involved suspending the pacemakers in a bath of degassified, deionized water firmly taped to a platform at the point of maximal pressure, i.e., second focal point (F2), where they received pressure shocks (means = 1300) from the HM3 Dornier lithotriptor. The pacemakers, programmed to their most sensitive setting, were continuously pacing at nominal outputs (atrial and ventricular pacing in the DDD mode). All units were assessed by a pacing system analyzer before and after the study, then underwent destructive analysis. During standard single chamber pacing (VVI) the pacing stimulus triggered ESWL. For dual chamber devices, ESWL was triggered by the atrial paced event which induced inhibition of the ventricular output in two pacemaker. This was eliminated by reprogramming to a less sensitive setting. The pacemaker can, hermetic seal and internal circuitry were undamaged in all units. Two rate responsive single chamber pacemakers had their activity sensing piezoelectric elements shattered when placed at F2. Two other units placed 5 cm from F2 were stimulated to their maximum upper programmed pacing rate with ESWL therapy, but were otherwise unaffected. Subsequent to this study, six patients with pacemakers programmed to the VVI (five), DDD (one) modes implanted in the thorax underwent successful ESWL without pacemaker or arrhythmic event. CONCLUSIONS: (A) It is generally safe for patients implanted with standard single chamber devices in a ventricular application to undergo ESWL without modifying the pacing/sensing parameters. (B) Patients implanted with dual chamber devices who pace in the atrium should be reprogrammed to the VVI mode during ESWL. (C) Patients with piezoelectric activity sensing rate responsive single chamber pacemakers should have this feature programmed off during ESWL and, if implanted in the abdomen, probably should not undergo ESWL.

Aged↗