PubMed Health⌕ Search

Biomedical subjects

B Ziaie

Publications and source records attributed to B Ziaie.

6 recordsLinked to original sources

A motorized microdrive for recording of neural ensembles in awake behaving rats.

The recording of neural ensembles in awake, behaving rats has been an extremely successful experimental paradigm, providing demonstrable scientific advances. Dynamic control of the position of the implanted electrodes is of key importance as mobile electrodes provide a better signal-to-noise ratio and a better cell/ electrode yield than nonmobile electrodes. Here we describe the use of low cost, soon to be commercially available dc motors to successfully control the depth of electrodes. The prototype designed is approximately 30 mm in diameter and 50 mm in length and weighed about 30 gms. This paper presents the results of linear displacements of electrodes achievable with this motorized microdrive.

Action Potentials↗

A self-oscillating detuning-insensitive class-E transmitter for implantable microsystems.

This paper describes a low-cost, self-oscillating, detuning-in-sensitive, class-E driver for transcutaneous power and data transmission to implantable microsystems. A voltage feedback scheme using a fast comparator for zero-crossing detection and a CMOS start-up circuit were used to stabilize the class-E operation for various transmitter coil inductance values. This technique solves the common problem of mismatch between the switching frequency of the driving device and the resonant frequency of the load network, which can cause excessive power loss and damage to the active device. Data is transmitted by AM modulation of the carrier through switching the power supply between two levels. The transmitter uses a 9-V supply, consumes 212 mA, operates at 3.9 MHz, and has an efficiency of 71%. The efficiency is stable (< 2% change) against 13% variations in the inductance value of a pancake shaped transmitter coil. Index Terms-Biomedical microsystems, class-E transmitter, implantable electronics, inductive powering, transcutaneous links.

Electric Power Supplies↗

An ultralight biotelemetry backpack for recording EMG signals in moths.

A two-channel FM biopotential recording system fabricated on a foldable, lightweight, polyimide substrate is presented. Each channel consists of a biopotential amplifier followed by a Colpitts oscillator with operating frequency tunable in the 88-108 MHz commercial FM band. The overall system measures 10 mm X 10 mm X 3 mm, weighs 0.74 g, uses two 1.5-V batteries, dissipates about 2 mW, and has a transmission range of 2 m. Using this system, electromyogram signals have been recorded from the dorsal ventral muscle and the dorsal longitudinal muscle of a giant sphinx moth (manduca sexta).

Animals↗

Intraocular pressure measurement at the choroid surface: a feasibility study with implications for implantable microsystems.

AIMS: To demonstrate that a sensor, which is inserted through the sclera and placed in intimate contact with the choroid, can reliably detect changes in the intraocular pressure (IOP). METHODS: A manometer was used to control the IOP of three cadaver eyes in steps of 7 mm Hg. A piezoresistive pressure sensor was used to measure the pressure at the choroid through a 2.5 mm diameter hole that was surgically removed from the sclera. Data were collected for two configurations; with the sensor: (i) rigidly attached to a miniature positioning stage, and (ii) sutured to the sclera. RESULTS: Both configurations accurately tracked the manometer pressure from 10 mm Hg to 47 mm Hg. For the fixed sensor cases, the average difference between the pressure measured at the choroid and in the anterior chamber was 0.8 mm Hg for the three eyes. For the sutured sensor case, the average difference was 2.1 mm Hg-although a significant portion of this was attributed to an initial offset. The standard deviations at each pressure level for all of the choroid measurements were under 1.0 mm Hg. CONCLUSIONS: Small changes in IOP can be accurately measured by a sensor in contact with the surface of the choroid, for both a fixed sensor configuration and for a sensor sutured to the sclera. These results are the first step in the realisation of a surgically implantable microsensor to monitor IOP for patients suffering from low tension and other difficult to manage forms of glaucoma.

Choroid↗

A modular micromachined high-density connector system for biomedical applications.

This paper presents a high-density, modular, low-profile, small, and removable connector system developed using micromachining technologies for biomedical applications. This system consists of a silicon or polyimide electrode with one end in contact with the biological tissue and its back-end supported in a titanium base (12.5 mm in diameter and 2.5 mm in height) that is fixed on the test subject. An external glass substrate (6 x 6 x 0.75 mm3), which supports a flexible polyimide diaphragm and CMOS buffers, is attached to the titanium base whenever electrical contact is required. The polyimide flexible diaphragm contains high-density gold electroplated pads (32 pads, each having an area of 100 x 100 micron 2 and separated by 150 microns) which match similar pads on the electrode back-end. When vacuum is applied between the two, the polyimide diaphragm deflects and the corresponding gold pads touch, therefore, establishing electrical connection. In vitro electrical tests in saline solution have been performed on a 32-site connector system demonstrating < 5 omega contact resistance, which remained stable after 70 connections, and -55 dB crosstalk at 1 kHz between adjacent channels. In vivo experiments have also confirmed the establishment of multiple contacts and have produced simultaneous biopotential recordings from the guinea pig occipital cortex.

Animals↗

A single-channel implantable microstimulator for functional neuromuscular stimulation.

This paper describes a single-channel implantable microstimulator for functional neuromuscular stimulation. This device measures 2 x 2 x 10 mm3 and can be inserted into paralyzed muscle groups by expulsion from a hypodermic needle. Power and data to the device are supplied from outside by RF telemetry using an amplitude-modulated 2-MHz RF carrier generated using a high-efficiency class-E transmitter. The transmitted signal carries a 5-b address which selects one of the 32 possible microstimulators. The selected device then delivers up to 2 microC of charge store in a tantalum chip capacitor for up to 200 microseconds (10 mA) into loads of < 800 omega through a high-current thin-film iridium-oxide (IrOx) electrode (approximately 0.3 mm2 in area). A bi-CMOS receiver circuitry is used to: generate two regulated voltage supplies (4.5 and 9 V), recover a 2-MHz clock from the carrier, demodulate the address code, and activate the output current delivery circuitry upon the reception of an external command. The overall power dissipation of the receiver circuitry is 45-55 mW. The implant is hermetically packaged using a custom-made glass capsule.

Electric Stimulation Therapy↗