PubMed Health⌕ Search

Biomedical subjects

Bahram Javidi

Publications and source records attributed to Bahram Javidi.

15 recordsLinked to original sources

Three-dimensional integral imaging with large depth of focus by use of real and virtual image fields.

We present an integral imaging method to enhance the depth of a three-dimensional image by displaying it throughout real and virtual image fields. When the product of depth and resolution square of the displayed three-dimensional image is used as a figure of merit in integral imaging systems, our method can maximize this merit especially when three-dimensional images with large depth of focus are displayed. The feasibility of our method is experimentally demonstrated by generation of elemental images by a computer.

Journal Article↗

Enhanced three-dimensional integral imaging system by use of double display devices.

We propose an enhanced three-dimensional (3D) integral imaging system using multiple display devices. Experimental results with double devices prove the improvement in the image depth for a given image quality. We present experiments on an enhanced 3D integral imaging system using double display devices, in which two 3D subimages that cover different depth ranges are separately generated in each device, and then they are combined with a beam splitter to reconstruct the whole 3D image with an enhanced depth of view. In a similar manner, the double-device system can also be used to obtain a wider viewing angle by combining two images with different viewing angle ranges. We discuss the possibility of 3D integral imaging systems using multiple display devices as extensions of the system with double display devices.

Journal Article↗

Improvement of viewing angle in integral imaging by use of moving lenslet arrays with low fill factor.

Lenslet arrays with a low fill factor can improve the viewing angle in integral imaging. However, the viewing resolution is degraded by low fill-factor lenslets because the spatial sampling rate of the ray information is reduced. We show that both the viewing resolution and the viewing angle of integral imaging can be improved by adopting a moving array-lenslet technique.

Journal Article↗

Secure optical data storage with random phase key codes by use of a configuration of a joint transform correlator.

A secure optical storage based on a configuration of a joint transform correlator by use of a photorefractive material is presented. A key code designed through the use of an optimized algorithm so that its Fourier transform has a uniform amplitude distribution and a uniformly random phase distribution is introduced. Original two-dimensional data and the key code are placed side-by-side at the input plane. Both of them are stored in a photorefractive material as a joint power spectrum. The retrieval of the original data can be achieved with the same key code. We can record multiple two-dimensional data in the same crystal by angular multiplexing and/or key code multiplexing.

Journal Article↗

Watermarking of three-dimensional objects by digital holography.

We present an optical method for information watermarking of three-dimensional (3D) objects by digital holography. A hidden image is embedded by double phase encoding in a phase-shift digital hologram of the 3D object. We decode the watermarked hologram to reconstruct the hidden image and the 3D object. We use either the entire hologram or a part of it to decode the hidden image. Experiments are presented to illustrate the ability to recover both the 3D object and the decoded hidden image. Digital holograms of the 3D object are obtained by optical experiments. The watermarking process, 3D object reconstruction, and hidden image recovery are performed digitally. To the best of our knowledge, this is the first report of 3D object watermarking by use of a phase encoding technique and digital holography.

Journal Article↗

Real-time three-dimensional object reconstruction by use of a phase-encoded digital hologram.

A three-dimensional (3D) object reconstruction technique that uses only phase information of a phase-shifting digital hologram and a phase-only spatial-light modulator is proposed. It is well known that a digital hologram can store both amplitude and phase information of an optical electric field and can reconstruct the original 3D object in a computer. We demonstrate that it is possible to reconstruct optically 3D objects using only phase information of the optical field calculated from phase-shifting digital holograms. The use of phase-only information enables us to reduce the amount of data in the digital hologram and reconstruct optically the 3D objects using a liquid-crystal spatial light modulator without optical power loss. Numerical evaluation of the reconstructed 3D object is presented.

Journal Article↗

Information hiding technique with double phase encoding.

We propose a technique for information hiding using double phase encoding. The proposed method uses a weighted double phase-encoded hidden image added to a host image referred to as the transmitted image. We develop an analytical presentation for the system performance using the statistical properties of double phase encoding. The peak signal-to-noise-ratio metric is used as a measure for the degradation in the quality of the host image and the recovered hidden image. We test, analytically, the distortion of the hidden image that is due to the host image and the effect of occlusion of the pixels of the transmitted image (that is, the host image containing the hidden image). Moreover, we discuss the effect of using only the real part of the transmitted image to recover the hidden image. Computer simulations are presented to test the system performance against these types of distortion. The simulations illustrate the system ability to recover the hidden image under distortions and the robustness of the hidden image against removal trials.

Journal Article↗

Digital three-dimensional image correlation by use of computer-reconstructed integral imaging.

We use integral images of a three-dimensional (3D) scene to estimate the longitudinal depth of multiple objects present in the scene. With this information, we digitally reconstruct the objects in three dimensions and compute 3D correlations of input objects. We investigate the use of nonlinear techniques for 3D correlations. We present experimental results for 3D reconstruction and correlation of 3D objects. We demonstrate that it is possible to perform 3D segmentation of 3D objects in a scene. We finally present experiments to demonstrate that the 3D correlation is more discriminant than the two-dimensional correlation.

Journal Article↗

Viewing-angle enhancement of speckle-reduced volume holographic three-dimensional display by use of integral imaging.

In a conventional integral imaging system the viewing angle is limited by the f-number of the microlens. To overcome this limitation we employ a phase-conjugate beam to read out elemental images, which are stored in photorefractive volume holographic storage, while the rotating diffuser reduces the speckle noise. In the proposed system the viewing angle can be enhanced over the f-number limitation. Experimental results and discussions of viewing parameters are presented.

Journal Article↗

Theoretical analysis for three-dimensional integral imaging systems with double devices.

By adoption of double-device systems, integral imaging can be enhanced in image depth, viewing angle, or image size. Theoretical analyses are done for the double-image-plane integral imaging systems. Both ray optics analysis and wave optics analysis confirm that the double-device integral imaging systems can pick up and display images at two separate image planes. The analysis results are also valuable in the understanding of the conventional integral imaging systems for image positions off the central depth plane.

Journal Article↗

Real-time all-optical three-dimensional integral imaging projector.

We present an all-optical three-dimensional integral imaging projector. An optically addressed spatial-light modulator is used, which potentially provides better image resolution than the conventional CCD and liquid-crystal display pair. We present experimental results using a liquid-crystal light valve.

Journal Article↗

Compression of digital holograms for three-dimensional object reconstruction and recognition.

We present the results of applying lossless and lossy data compression to a three-dimensional object reconstruction and recognition technique based on phase-shift digital holography. We find that the best lossless (Lempel-Ziv, Lempel-Ziv-Welch, Huffman, Burrows-Wheeler) compression rates can be expected when the digital hologram is stored in an intermediate coding of separate data streams for real and imaginary components. The lossy techniques are based on subsampling, quantization, and discrete Fourier transformation. For various degrees of speckle reduction, we quantify the number of Fourier coefficients that can be removed from the hologram domain, and the lowest level of quantization achievable, without incurring significant loss in correlation performance or significant error in the reconstructed object domain.

Journal Article↗

Speckle-reduced three-dimensional volume holographic display by use of integral imaging.

We propose a method to implement a speckle-reduced coherent three-dimensional (3D) display system by a combination of integral imaging and photorefractive volume holographic storage. The 3D real object is imaged through the microlens array and stored in the photorefractive crystal. During the reconstruction process a phase conjugate reading beam is used to minimize aberration, and a rotating diffuser located on the imaging plane of the lens array is employed to reduce the speckle noise. The speckle-reduced 3D image with a wide viewing angle can be reconstructed by use of the proposed system. Experimental results are presented and optical parameters of the proposed system are discussed in detail.

Journal Article↗

Distortion tolerant image recognition receiver by use of a multiple-hypothesis method.

A multiple-hypothesis method is used to detect a target or a reference signal in the presence of additive noise with unknown statistics. The receiver is designed to detect the target and to be tolerant of the variations in rotation and illumination of the target. A multiple-hypothesis test with unknown-noise parameters is used to locate the target position. The proposed method does not use any specific distortion-invariant-filtering technique, but it relies on a multiple-hypothesis approach. Maximum-likelihood estimates of the illumination constant and the unknown noise parameters are obtained. Computer simulations are presented to evaluate the performance of the receiver for various distorted noisy true-class targets with varying illumination and false-class objects.

Journal Article↗

Optimum nonlinear composite filter for distortion-tolerant pattern recognition.

We describe a nonlinear distortion-tolerant filter for pattern recognition that is optimum in terms of tolerance to input noise and discrimination capability. This filter was derived by minimization of the output energy that is due to the overlapping additive noise and the input scene, and the output of the filter meets the design constraints obtained from the training data set. The performance of this filter was tested with an input scene containing one of the training data sets, a nontraining true target, and a false object in the presence of overlapping additive noise and nonoverlapping background noise. We carried out Monte Carlo runs to measure the statistical performance of the filter and obtained receiver operating characteristics curves to show the detection capabilities of the filter.

Journal Article↗