PubMed Health⌕ Search

Biomedical subjects

Barbara Ensoli

Publications and source records attributed to Barbara Ensoli.

56 records · Page 4Linked to original sources

Angiogenic effects of extracellular human immunodeficiency virus type 1 Tat protein and its role in the pathogenesis of AIDS-associated Kaposi's sarcoma.

The Tat protein of human immunodeficiency virus (HIV) type 1 is a transactivator of viral gene expression that is required for virus replication and spread. Moreover, Tat is released by acutely HIV-infected cells via a leaderless secretory pathway and in a biologically active form that exerts effects on both HIV-infected and uninfected cells from different organs and systems. This review focuses on the activities of extracellular Tat protein on endothelial cells, on angiogenesis, and on the pathogenesis of AIDS-associated angioproliferative diseases such as Kaposi's sarcoma. In particular, we discuss results from different groups indicating that Tat mimics the proangiogenic activities of extracellular matrix molecules and that it enhances the effects of angiogenic factors.

AIDS-Related Opportunistic Infections↗

Calibrated real-time PCR assay for quantitation of human herpesvirus 8 DNA in biological fluids.

Accurate laboratory tests for the diagnosis of active human herpesvirus 8 (HHV-8) infection are becoming essential to study the pathogenesis of HHV-8-associated tumors and for the clinical management of HHV-8-infected individuals. We have developed a highly sensitive, calibrated quantitative real-time PCR assay for the measurement of cell-free HHV-8 DNA in body fluids, based on the addition of a synthetic DNA calibrator prior to DNA extraction. The calibrator controls each sample for the presence of PCR inhibitors, determines a cutoff value of sensitivity for negative samples, and normalizes positive samples for the efficiency of DNA recovery. The assay shows a wide dynamic range of detection (between 1 and 10(6) viral genome equivalents/reaction) and a high degree of accuracy even in the presence of high amounts (up to 1 micro g) of human genomic DNA. Moreover, the assay has a very high sensitivity (lower detection limit, 10 genome equivalents/ml) and a high degree of reproducibility and repeatability with a coefficient of variation (CV) of <15 and 23%, respectively. Furthermore, the use of the calibrator improves the accuracy of quantitation and decreases the intersample variability (CV, 9 and 6%, respectively). The sensitivity and specificity of the assay were tested with a series of clinical specimens obtained from patients affected by various HHV-8-related diseases, as well as from a wide number of controls. In conclusion, our calibrated real-time PCR assay provides a reliable high-throughput method for quantitation of HHV-8 DNA in clinical and laboratory specimens.

AIDS-Related Opportunistic Infections↗