PubMed Health⌕ Search

Biomedical subjects

Barry L Karger

Publications and source records attributed to Barry L Karger.

At least 19 recordsLinked to original sources

An unconventional pathway for reduction of CO2 to methane in CO-grown Methanosarcina acetivorans revealed by proteomics.

Methanosarcina acetivorans produces acetate, formate, and methane when cultured with CO as the growth substrate [Rother M, Metcalf WW (2004) Proc Natl Acad Sci USA 101:], which suggests novel features of CO metabolism. Here we present a genome-wide proteomic approach to identify and quantify proteins differentially abundant in response to growth on CO versus methanol or acetate. The results indicate that oxidation of CO to CO2 supplies electrons for reduction of CO2 to a methyl group by steps and enzymes of the pathway for CO2 reduction determined for other methane-producing species. However, proteomic and quantitative RT-PCR results suggest that reduction of the methyl group to methane involves novel methyltransferases and a coenzyme F420H2:heterodisulfide oxidoreductase system that generates a proton gradient for ATP synthesis not previously described for pathways reducing CO2 to methane. Biochemical assays support a role for the oxidoreductase, and transcriptional mapping identified an unusual operon structure encoding the oxidoreductase. The proteomic results further indicate that acetate is synthesized from the methyl group and CO by a reversal of initial steps in the pathway for conversion of acetate to methane that yields ATP by substrate level phosphorylation. The results indicate that M. acetivorans utilizes a pathway distinct from all known CO2 reduction pathways for methane formation that reflects an adaptation to the marine environment. Finally, the pathway supports the basis for a recently proposed primitive CO-dependent energy-conservation cycle that drove and directed the early evolution of life on Earth.

Acetates↗

Kinase activity of overexpressed HipA is required for growth arrest and multidrug tolerance in Escherichia coli.

Overexpression of the HipA protein of the HipBA toxin/antitoxin module leads to multidrug tolerance in Escherichia coli. HipA is a "toxin" that causes reversible dormancy, whereas HipB is an antitoxin that binds HipA and acts as a transcriptional repressor of the hipBA operon. Comparative sequence analysis shows that HipA is a member of the phosphatidylinositol 3/4-kinase superfamily. The kinase activity of HipA was examined. HipA was autophosphorylated in the presence of ATP in vitro, and the purified protein appeared to carry a single phosphate group on serine 150. Thus, HipA is a serine kinase that is at least partially phosphorylated in vivo. Overexpression of HipA caused inhibition of cell growth and increase in persister formation. Replacing conserved aspartate 309 in the conserved kinase active site or aspartate 332 in the Mg2+-binding site with glutamine produced mutant proteins that lost the ability to stop cellular growth upon overexpression. Replacing serine 150 with alanine yielded a similarly inactive protein. The mutant proteins were then examined for their ability to increase antibiotic tolerance. Cells overexpressing wild-type HipA were highly tolerant to cefotaxime, a cell wall synthesis inhibitor, to ofloxacin, a fluoroquinolone inhibitor of DNA gyrase, and to topoisomerase IV and were almost completely resistant to killing by mitomycin C, which forms DNA adducts. The mutant proteins did not protect cells from cefotaxime or ofloxacin and had an impaired ability to protect from mitomycin C. Taken together, these results suggest that the protein kinase activity of HipA is essential for persister formation.

Amino Acid Sequence↗

Dynamic profiling of the post-translational modifications and interaction partners of epidermal growth factor receptor signaling after stimulation by epidermal growth factor using Extended Range Proteomic Analysis (ERPA).

In a recent report, we introduced Extended Range Proteomic Analysis (ERPA), an intermediate approach between top-down and bottom-up proteomics, for the comprehensive characterization at the trace level (fmol level) of large and complex proteins. In this study, we extended ERPA to determine quantitatively the temporal changes that occur in the tyrosine kinase receptor, epidermal growth factor receptor (EGFR), upon stimulation. Specifically A 431 cells were stimulated with epidermal growth factor after which EGFR was immunoprecipitated at stimulation times of 0, 0.5, 2, and 10 min as well as 4 h. High sequence coverage was obtained (96%), and methods were developed for label-free quantitation of phosphorylation and glycosylation. A total of 13 phosphorylation sites were identified, and the estimated stoichiometry was determined over the stimulation time points, including Thr(P) and Ser(P) sites in addition to Tyr(P) sites. A total of 10 extracellular domain N-glycan sites were also identified, and major glycoforms at each site were quantitated. No change in the extent of glycosylation with stimulation was observed as expected. Finally potential binding partners to EGFR were identified based on changes in the amount of protein pulled down with EGFR as a function of time of stimulation. Many of the 19 proteins identified are known binding partners of EGFR. This work demonstrates that comprehensive characterization provides a powerful tool to aid in the study of important therapeutic targets. The detailed molecular information will prove useful in future studies in tissue.

Amino Acid Sequence↗

New algorithm for 15N/14N quantitation with LC-ESI-MS using an LTQ-FT mass spectrometer.

A new algorithm (QN) for the (15)N /(14)N quantitation of relative protein abundances in complex proteomic samples is described. QN takes advantage of the high resolution, mass accuracy and throughput of the hybrid mass spectrometer LTQ-FT MS. Peptide quantitation is based on MS peak intensity (measured in the FT MS), while peptide identification is performed in the MS/MS mode (measured in the LTQ linear ion trap). Accuracy of the protein abundance is enhanced by a novel scoring procedure, allowing filtering of less reliable measurements of peptide abundances. The performance of QN is illustrated in the relative quantitative analysis of M. acetivorans C2A cultures grown with carbon monoxide vs methanol as substrate. Roughly 1,000 proteins were quantitated with an average CV of 9% for the protein abundance ratios. QN performs quantitation without manual intervention, does not require high processing power, and generates files compatible with the Guidelines for Proteomic Data Publication.

Algorithms↗

Electron transport in the pathway of acetate conversion to methane in the marine archaeon Methanosarcina acetivorans.

A liquid chromatography-hybrid linear ion trap-Fourier transform ion cyclotron resonance mass spectrometry approach was used to determine the differential abundance of proteins in acetate-grown cells compared to that of proteins in methanol-grown cells of the marine isolate Methanosarcina acetivorans metabolically labeled with 14N versus 15N. The 246 differentially abundant proteins in M. acetivorans were compared with the previously reported 240 differentially expressed genes of the freshwater isolate Methanosarcina mazei determined by transcriptional profiling of acetate-grown cells compared to methanol-grown cells. Profound differences were revealed for proteins involved in electron transport and energy conservation. Compared to methanol-grown cells, acetate-grown M. acetivorans synthesized greater amounts of subunits encoded in an eight-gene transcriptional unit homologous to operons encoding the ion-translocating Rnf electron transport complex previously characterized from the Bacteria domain. Combined with sequence and physiological analyses, these results suggest that M. acetivorans replaces the H2-evolving Ech hydrogenase complex of freshwater Methanosarcina species with the Rnf complex, which generates a transmembrane ion gradient for ATP synthesis. Compared to methanol-grown cells, acetate-grown M. acetivorans synthesized a greater abundance of proteins encoded in a seven-gene transcriptional unit annotated for the Mrp complex previously reported to function as a sodium/proton antiporter in the Bacteria domain. The differences reported here between M. acetivorans and M. mazei can be attributed to an adaptation of M. acetivorans to the marine environment.

Acetates↗

Enhanced characterization of complex proteomic samples using LC-MALDI MS/MS: exclusion of redundant peptides from MS/MS analysis in replicate runs.

Due to the complexity of proteome samples, only a portion of peptides and thus proteins can be identified in a single LC-MS/MS analysis in current shotgun proteomics methodologies. It has been shown that replicate runs can be used to improve the comprehensiveness of the proteome analysis; however, high-intensity peptides tend to be analyzed repeatedly in different runs, thus reducing the chance of identifying low-intensity peptides. In contrast to commonly used online ESI-MS, offline MALDI decouples the separation from MS acquisition, thus allowing in-depth selection for specific precursor ions. Accordingly, we extended a strategy for offline LC-MALDI MS/MS analysis using a precursor ion exclusion list consisting of all identified peptides in preceding runs. The exclusion list eliminated redundant MS/MS acquisitions in subsequent runs, thus reducing MALDI sample depletion and allowing identification of a larger number of peptide identifications in the cumulative dataset. In the analysis of the digest of an Escherichia coli lysate, the exclusion list strategy resulted in a 25% increase in the number of unique peptide identifications in the second run, in contrast to simply pooling MS/MS data from two replicate runs. To reduce the increased LC analysis time for repeat runs, a four-column multiplexed LC system was developed to carry out separation simultaneously. The multiplexed LC-MALDI MS provides a high-throughput platform to utilize the exclusion list strategy in proteome analysis.

Amino Acid Sequence↗

High-speed, high-resolution monolithic capillary LC-MALDI MS using an off-line continuous deposition interface for proteomic analysis.

High-speed, high-resolution LC separations, using a poly(styrene-divinylbenzene) monolithic column, have been coupled to MALDI MS and MS/MS through an off-line continuous deposition interface. The LC eluent was mixed with alpha-cyano-4-hydroxycinnamic acid matrix solution and deposited on a MALDI plate that had been precoated with nitrocellulose. Deposition at subatmospheric pressure (80 Torr) formed a 250-microm-wide serpentine trace with uniform width and microcrystalline morphology. The deposited trace was then analyzed in the MS mode using a MALDI-TOF/TOF MS instrument. Continuous deposition allowed interrogation of the separation with a high data sampling rate in the chromatographic dimensions, thus preserving the high resolution of narrow peaks (3-5-s peak width at half-height) of the fast monolithic LC. No extracolumn band broadening due to the deposition process was observed. Over 2000 components were resolved in a 10-min linear gradient separation of the model sample, and 386 unique peptides were identified in the subsequent MS/MS analysis. The continuous deposition interface allows the coupling of high-resolution separations to MALDI MS without degradation in separation efficiency, thus enabling high-throughput proteome analysis.

Amino Acid Sequence↗

Coumarin tags for analysis of peptides by MALDI-TOF MS and MS/MS. 2. Alexa Fluor 350 tag for increased peptide and protein Identification by LC-MALDI-TOF/TOF MS.

The goal of this study was the development of N-terminal tags to improve peptide identification using high-throughput MALDI-TOF/TOF MS. Part 1 of the study was focused on the influence of derivatization on the intensities of MALDI-TOF MS signals of peptides. In part 2, various derivatization approaches for the improvement of peptide fragmentation efficiency in MALDI-TOF/TOF MS are explored. We demonstrate that permanent cation tags, while significantly improving signal intensity in the MS mode, lead to severe suppression of MS/MS fragmentation, making these tags unsuitable for high-throughput MALDI-TOF/TOF MS analysis. In the present work, it was found that labeling with Alexa Fluor 350, a coumarin tag containing a sulfo group, along with guanidation of epsilon-amino groups of Lys, could enhance unimolecular fragmentation of peptides with the formation of a high-intensity y-ion series, while the peptide intensities in the MS mode were not severely affected. LC-MALDI-TOF/TOF MS analysis of tryptic peptides from the SCX fractions of an E. coli lysate revealed improved peptide scores, a doubling of the total number of peptides, and a 30% increase in the number of proteins identified, as a result of labeling. Furthermore, by combining the data from native and labeled samples, confidence in correct identification was increased, as many proteins were identified by different peptides in the native and labeled data sets. Additionally, derivatization was found not to impair chromatographic behavior of peptides. All these factors suggest that labeling with Alexa Fluor 350 is a promising approach to the high-throughput LC-MALDI-TOF/TOF MS analysis of proteomic samples.

Acetates↗

Design of an automated multicapillary instrument with fraction collection for DNA mutation discovery by constant denaturant capillary electrophoresis (CDCE).

A fundamental goal ingenomics is the discovery of genetic variation that contributes to disease states or to differential drug responses. Single nucleotide polymorphism (SNP) detection has been the focus of much attention in the study of genetic variation over the last decade. These SNPs typically occur at a frequency greater than 1% in the human genome. Recently, low-frequency alleles are also being increasingly recognized as critical to obtain an improved understanding of the correlation between genetic variation and disease. Although many methods have been reported for the discovery and scoringof SNPs, sensitive, automated, and cost-effective methods and platforms for the discovery of low-frequency alleles are not yet readily available. We describe here an automated multicapillary instrument for high-throughput detection of low-frequency alleles from pooled samples using constant denaturant capillary electrophoresis. The instrument features high optical sensitivity (1 x 10(-12) M fluorescein detection limit), precise and stable temperature control (+/- 0.01degrees C), and automation for sample delivery, injection, matrix replacement, and fraction collection. The capillary array is divided into six groups of four capillaries, each of which can be independently set at any temperature ranging from room temperature to 90 degrees C. The key performance characteristics of the instrument are reported.

Antigens, CD↗

Increased identification of peptides by enhanced data processing of high-resolution MALDI TOF/TOF mass spectra prior to database searching.

This paper presents application of sequential enhanced data processing procedures to high-resolution tandem mass spectra for identification of peptides using the Mascot database search algorithm. A strategy for (1) selection of fragment ion peaks from MS/MS spectra, (2) utilization of improved mass accuracy of the precursor ions, and (3) wavelet denoising of the mass spectra prior to fragment ion selection have been developed. The number of peptide identifications obtained using the enhanced processing was then compared with that obtained using software provided by the instrument manufacturer. Approximately 9000 MS/MS spectra acquired by the Applied Biosystems 4700 TOF/TOF MS instrument were used as a model data set. After application of the new processing, an increase of 33% unique peptides and 22% protein identifications with at least two unique peptides were found. The influence of the processing on the percentage of false positives, estimated by searching against a randomized database, was estimated to increase false positive identifications from 2.7 to 3.9%, which was still below the 5% error rate specified in the Mascot search. These data processing approaches increase the amount of information that can be extracted from LC-MS analysis without the necessity of additional experiments.

Algorithms↗

Coumarin tags for improved analysis of peptides by MALDI-TOF MS and MS/MS. 1. Enhancement in MALDI MS signal intensities.

The goal of this study was the development of N-terminal tags to improve peptide identification using high-throughput MALDI-TOF MS and MS/MS. The proposed tags, commercially available fluorescent derivatives of coumarin, can be advantageous for peptide analysis in both MS and MS/MS modes. This paper, part 1, will focus on the influence of derivatization on the intensities of MALDI-TOF MS signals of peptides. Labeling peptides with tags containing the coumarin core was found to enhance the intensities of peptide peaks (in some cases over 40-fold) in MALDI-TOF MS using CHCA and 2,5-DHAP matrixes. The signal enhancement was found to be peptide- and matrix-dependent, being the most pronounced for hydrophilic peptides. No correlation was found between the UV absorptivity of the tags at the excitation wavelengths typical for UV-MALDI and the magnitude of the signal enhancement. Interestingly, peptides labeled with Alexa Fluor 350, a coumarin derivative containing a sulfo group (i.e., bearing strong negative charge), showed a 5-15-fold increase in intensity of MALDI MS signal in the positive ion mode, relative to the underivatized peptides, when 2,5-DHAP was used as the matrix. The Alexa Fluor 350 tag yielded a significantly higher signal relative to that for the CAF tag, likely due to the increased hydrophobicity of the coumarin structure. With 2,5-DHB, a decrease of MALDI MS signal was observed for all coumarin-labeled peptides, again relative to the unlabeled species. These findings support the hypothesis that derivatization with coumarin, a relatively hydrophobic structure, improves incorporation of hydrophilic peptides into hydrophobic MALDI matrixes, such as CHCA and 2,5-DHAP.

Amino Acid Sequence↗

A new and sensitive on-line liquid chromatography/mass spectrometric approach for top-down protein analysis: the comprehensive analysis of human growth hormone in an E. coli lysate using a hybrid linear ion trap/Fourier transform ion cyclotron resonance mass spectrometer.

A sensitive, integrated top-down liquid chromatography/mass spectrometry (LC/MS) approach, suitable for the near complete characterization of specific proteins in complex protein mixtures, such as inclusion bodies of an E. coli lysate, has been successfully developed using a hybrid linear ion trap/Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. In particular, human growth hormone (hGH) (200 fmol) was analyzed with high sequence coverage (>95%), including the sites of disulfide linkages. The high mass accuracy and resolution of the FTICR mass spectrometer was used to reveal high charge state ions of hGH (22 kDa). The highly charged intact protein ions (such as the 17+ species) were captured and fragmented in the linear ion trap cell. The fragment ions from MS/MS spectra were then successfully analyzed in the FTICR cell in an on-line LC/MS run. Peptide fragments from the N-terminal and C-terminal regions, as well as large interior fragments, were captured and identified. The results allowed the unambiguous assignment of disulfide bonds Cys53-Cys165 and Cys182-Cys189, indicative of proper folding of hGH. The disulfide bond assignments were also confirmed by analysis of the tryptic digest of a sample of hGH purified from inclusion bodies. On-line LC/MS with the linear ion trap/FTICR yields high mass accuracy in both the MS and MS/MS modes (within 2 ppm with external calibration). The approach should prove useful in biotechnology applications to characterize correctly folded proteins, both in the early protein expression and the later processed stages, using only a single automated on-line LC/MS top-down method.

Amino Acid Sequence↗

A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain.

A new denoising and peak picking algorithm (MEND, matched filtration with experimental noise determination) for analysis of LC-MS data is described. The algorithm minimizes both random and chemical noise in order to determine MS peaks corresponding to sample components. Noise characteristics in the data set are experimentally determined and used for efficient denoising. MEND is shown to enable low-intensity peaks to be detected, thus providing additional useful information for sample analysis. The process of denoising, performed in the chromatographic time domain, does not distort peak shapes in the m/z domain, allowing accurate determination of MS peak centroids, including low-intensity peaks. MEND has been applied to denoising of LC-MALDI-TOF-MS and LC-ESI-TOF-MS data for tryptic digests of protein mixtures. MEND is shown to suppress chemical and random noise and baseline fluctuations, as well as filter out false peaks originating from the matrix (MALDI) or mobile phase (ESI). In addition, MEND is shown to be effective for protein expression analysis by allowing selection of a large number of differentially expressed ICAT pairs, due to increased signal-to-noise ratio and mass accuracy.

Algorithms↗

Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-microm-i.d. polystyrene-divinylbenzene monolithic capillary columns.

This work explores the use of 20-microm-i.d. polymeric polystyrene-divinylbenzene monolithic nanocapillary columns for the LC-ESI-MS analysis of tryptic digest peptide mixtures. In contrast to the packing of microparticles, capillary columns were prepared, without the need of high pressure, in fused-silica capillaries, by thermally induced in situ copolymerization of styrene and divinylbenzene. The polymerization conditions and mobile-phase composition were optimized for chromatographic performance leading to efficiencies over 100000 plates/m for peptide separations. High mass sensitivity (approximately 10 amol of peptides) in the MS and MS/MS modes using an ion trap MS was found, a factor of up to 20-fold improvement over 75-microm-i.d. nanocolumns. A wide linear dynamic range (approximately 4 orders of magnitude) was achieved, and good run-to-run and column-to-column reproducibility of isocratic and gradient elution separations were found. As samples, both model proteins and tissue extracts were employed. Gradient nano-LC-MS analysis of a proteolytic digest of a tissue extract, equivalent to a sample size of approximately 1000 cells injected, is presented.

Amino Acid Sequence↗

Microfluidic device for capillary electrochromatography-mass spectrometry.

A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.

Electrophoresis, Capillary↗

High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.

High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.

Electrophoresis, Capillary↗

Application of high-resolution capillary array electrophoresis with automated fraction collection for GeneCalling trade mark analysis of the yeast genomic DNA.

Capillary array instrument was applied to transcript profiling of the yeast genomic DNA using GeneCalling trade mark chemistry. The instrument integrated a 12-capillary array for DNA separation with a replaceable sieving matrix, laser-induced fluorescence detection and an automated microfraction collector. The DNA fractions, exiting the separation capillaries, were continuously deposited in a 1536-well collection plate made of agarose gel. DNA fragments recovered from selected fractions were cloned and then sequenced. Over 80% of theoretically predicted fragments could be recovered in the collected fractions, cloned and sequenced with an average redundancy of threefold. Excellent correlation of the experimentally obtained sequences with the theoretically predicted gene fragments demonstrated the suitability of capillary array electrophoresis for micropreparative recovery of DNA fragments. This approach, useful especially for rapid DNA expression profiling of unknown genes for nonsequenced organisms, demonstrates the practical capability of the prototype multicapillary fraction collector.

Automation↗