Temperature and gas-phase composition measurements in supersonic flows using tunable diode laser absorption spectroscopy: the effect of condensation on the boundary-layer thickness.

We used a tunable diode laser absorption spectrometer and a static-pressure probe to follow changes in temperature, vapor-phase concentration of D2O, and static pressure during condensation in a supersonic nozzle. Using the measured static-pressure ratio p/p0 and the mass fraction of the condensate g as inputs to the diabatic flow equations, we determined the area ratio (A/A*)wet and the corresponding centerline temperature of the flow during condensation. From (A/A*)wet we determined the boundary-layer displacement thickness during condensation (delta#)wet. We found that (delta#)wet first increases relative to the value of delta# in a dry expansion (delta#)Dry before becoming distinctly smaller than (delta#)Dry downstream of the condensation region. After correcting the temperature gradient across the boundary layers, the temperature determined from p/p0 and g agreed with the temperature determined by the laser-absorption measurements within our experimental error (+/-2 K), except when condensation occurred too close to the throat. The agreement between the two temperature measurements let us draw the following two conclusions. First, the differences in the temperature and mole fraction of D2O determined by the two experimental techniques, first observed in our previous study [P. Paci, Y. Zvinevich, S. Tanimura, B. E. Wyslouzil, M. Zahniser, J. Shorter, D. Nelson, and B. McManus, J. Chem. Phys. 121, 9964 (2004)], can be explained sufficiently by changes in delta# caused by the condensation of D2O, except when the phase transition occurs too close to the throat. Second, the extrapolation of the equation, which expresses the temperature dependence of the heat of vaporization of bulk D2O liquid, is a good estimate of the heat of condensation of supercooled D2O down to 210 K.

Journal Article↗

Spatially resolved gas phase composition measurements in supersonic flows using tunable diode laser absorption spectroscopy.

We used a tunable diode laser absorption spectrometer to follow the condensation of D(2)O in a supersonic Laval nozzle. We measured both the concentration of the condensible vapor and the spectroscopic temperature as a function of position and compared the results to those inferred from static pressure measurements. Upstream and in the early stages of condensation, the quantitative agreement between the different experimental techniques is good. Far downstream, the spectroscopic results predict a lower gas phase concentration, a higher condensate mass fraction, and a higher temperature than the pressure measurements. The difference between the two measurement techniques is consistent with a slight compression of the boundary layers along the nozzle walls during condensation.

Journal Article↗

High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors.

A compact, fast response, mid-infrared absorption spectrometer using thermoelectrically (TE) cooled pulsed quantum cascade (QC) lasers and TE detectors has been developed to demonstrate the applicability of QC lasers for high precision measurements of nitrous oxide and methane in the earth's atmosphere. Reduced pressure extractive sampling with a 56 m path length, 0.5 l volume, multiple pass absorption cell allows a time response of <0.1s which is suitable for eddy correlation flux measurements for these gases. Precision of 0.3 ppb (rms, 1s averaging time) or 0.1% of the ambient concentration for N(2)O (4 ppb or 0.2% of ambient for CH(4)), has been demonstrated using QC lasers at 4.5 microm (7.9 microm for CH(4)), corresponding to an absorbance precision of 4 x 10(-5) Hz(-1/2) (8 x 10(-5) Hz(-1/2) for CH(4)). Stabilization of the temperature of the optical bench and the pulse electronics results in a minimum Allan variance corresponding to 0.06 ppb for N(2)O with an averaging time of 100 s (0.7 ppb with an averaging time of 200 s for CH(4)). The instrument is capable of long-term, unattended, continuous operation without cryogenic cooling of either laser or detector.

Air↗