Safety and efficacy of low-dose intravenous enoxaparin and GP IIb/IIIa inhibitor therapy during PCI.

The use of intravenous enoxaparin, a glyco-protein (GP) IIb/IIIa inhibitor, during percutaneous coronary intervention (PCI) has been shown to be safe and to possibly reduce in-hospital and 30-day major adverse cardiac events(MACE). NICE-4, a recent PCI observational study, evaluated a reduced dose of intravenous (IV) enoxaparin (0.75 mg/kg) with abciximab. However, prior PCI studies evaluating IV enoxaparin have not used percutaneous closure devices. The purpose of this study was to observe the safety and efficacy of a lower dose of IV enoxaparin (0.5 mg/kg) in conjunction with any GP IIb/IIIa inhibitor. The Angio-Seal femoral closure device was also employed as part of the treatment strategy. We administered 0.5 mg/kg IV enoxaparin and a GP IIIb/IIIa inhibitor to 75 eligible PCI patients. None received anticoagulation 24 hours prior to PCI; all received pre-procedural aspirin, post-procedural deployment of the Angio-Seal and clopidogrel therapy, and were discharged home within 36 hours. TIMI minor bleeding was 1.3%; there were no TIMI major bleeding events or major adverse cardiac events during in-hospital stay or at 30-day follow-up. Our small observational study shows that IV enoxaparin is safe and efficacious during PCI when given at a dose 33% lower than previously reported in conjunction with any GP IIb/IIIa inhibitor and Angio-Seal. However, large, randomized PCI trials are needed to confirm the clinical efficacy, safety and cost-effectiveness of lower doses of enoxaparin with GPIIb/IIIa inhibitors and vascular closure devices.

Aged↗

Left ventricular function in atrial fibrillation during overdrive pacing.

OBJECTIVE: Our purpose was to measure the effect of ventricular pacing in patients with atrial fibrillation (AF) on stroke volume and cardiac output. BACKGROUND: Unceasing variation in cycle length in AF decreases stroke volume and cardiac output. Because ventricular-inhibited pacing after atrioventricular node ablation has been reported to improve left ventricular performance, we tested the hypothesis that overdrive pacing would produce a similar benefit by regularizing cycle length. METHODS AND RESULTS: We studied 18 patients with chronic AF and permanent pacemakers. The aortic time velocity integral (TVI) was measured with continuous-wave Doppler and was used as a surrogate measure of stroke volume (stroke volume = TVI x aortic valve area, and aortic valve area is constant whether in AF or during pacing). For each patient, the linear relation between preceding cycle length and TVI in AF was used to estimate relative stroke volume (TVI compared within each patient) at a preceding cycle length of 666 ms in AF, and a similar comparison between AF and pacing was made at the minimum allowable pacing rate. Relative stroke volume in AF was then compared with relative stroke volume at both the fixed cycle (666 ms) and the minimum allowable rate. During pacing at 666 ms, relative stroke volume increased significantly by 18% (t = 2.8, P =.048), but there was no difference in cardiac output during pacing at the minimum possible rate and the corresponding preceding cycle length in AF. CONCLUSION: Our data suggest that regularization of ventricular rhythm by overdrive pacing in patients with AF only improves stroke volume (and by extension, cardiac output) at pacing rates at the outer limit of and above the normal physiologic range.

Adult↗