PubMed Health⌕ Search

Biomedical subjects

Beat Muller

Publications and source records attributed to Beat Muller.

4 recordsLinked to original sources

Using insulin pen needles up to five times does not affect needle tip shape nor increase pain intensity.

AIMS: Reusing insulin pen needles could help to reduce the increasing economic burden of diabetes. We tested the hypothesis that reusing insulin pen needles leads to needle tip deformity and increased pain. METHODS: Three blinded reviewers assessed 123 electron microscope pictures analyzing needle tip deformity of insulin pen needles used up to four times by diabetic subjects and up to five times by blinded non-diabetic volunteers. The estimated frequency of needle use was correlated to the actual number of needle use. Pain intensity and unpleasantness of each injection were measured by a visual analogue scale and their differences analyzed by Kruskal-Wallis analysis of variance. RESULTS: Unused needles could be differentiated visually from used needles. However, there was no correlation between the actual and guessed number of times a needle was used (r = 0.07, P = 0.2). Evaluating all 270 injections, neither pain intensity nor unpleasantness increased with repeated injections of the same needles in people with diabetes (P = 0.1 and 0.96) and in the volunteers (P = 0.63 and 0.92). CONCLUSIONS: Using pen needles four to five times does not lead to progressive needle tip deformity and does not increase pain intensity or unpleasantness, but could increase convenience and lead to substantial financial savings in Europe of around EUR 100 million/year.

Adult↗

On-site simultaneous determination of anions and cations in drainage water using a flow injection-capillary electrophoresis system with contactless conductivity detection.

Drainage water diverted from a farm pasture, which was heavily loaded with manure, was monitored during a rain event. Concurrent anion and cation determinations at intervals of 10 min could be achieved with a new capillary electrophoresis system employing dual injection at opposite ends of the separation capillary. The flow injection approach enabled automation of the sampling process. Interruption of the separation voltage was not necessary. Contactless conductivity detection with an electrolyte solution optimized for the purpose allowed the facile simultaneous detection of the inorganic ions Cl(-), NO(3)(-), SO(4)(2-), HPO(4)(2-), NO(2)(-), NH(4)(+), K(+), Ca(2+), Na(+) and Mg(2+) and the acquisition of temporal concentration profiles of these species. The detection limits achieved were between 20 and 200 [micro sign]g l(-1) for all ions and the repeatability of peak areas and peak heights was better than 1%. The quantitative results were verified by analysing individual samples later in the laboratory with photometry and ion chromatography and the average deviations were found to be between 4 and 12%. This contribution presents a further step in the development of capillary electrophoresis towards a fully automated, low maintenance field method.

Anions↗

Endocrine changes in critical illness.

The homeostatic corrections that have emerged in the course of human evolution to cope with catastrophic events involve a complex multisystem endeavor, of which the endocrine contribution is an integral component. Although the repertoire of endocrine changes has been probed in some detail, discerning the vulnerabilities and failure of this system is far more challenging. The ensuing endocrine topics illustrate some of the current issues reflecting attempts to gain an improved insight and clinical outcome for critical illness.

Adrenal Insufficiency↗