PubMed Health⌕ Search

Biomedical subjects

Becky L Massey

Publications and source records attributed to Becky L Massey.

4 recordsLinked to original sources

Stapedectomy in congenital stapes fixation: are hearing outcomes poorer?

OBJECTIVE: To evaluate outcomes of stapedectomy surgery for congenital stapes fixation. STUDY DESIGN: Retrospective chart review. METHODS: The charts of 463 stapedectomies performed by 1 surgeon from 1996 to 2003 were reviewed. Patients with a history of childhood hearing loss and operative findings consistent with congenital fixation of the stapes were included. Patients with a history of trauma or chronic otitis media and those with otosclerosis were excluded. Thirty-six patients underwent stapedectomy for congenital fixation. Revision cases and those with inadequate postoperative bone or air conduction data were excluded. Inclusion criteria were met for 25 patients. Operative findings and hearing outcomes were evaluated. RESULTS: The study group was comprised of 25 stapedectomies. Closure of the air-bone gap to less than 10 dB was achieved in 48% of cases, and 80% had closure within 20 dB. A gap of more than 30 dB remained in 3 cases. There were 2 cases of sensorineural hearing loss with worsening of the bone conduction thresholds by 15 dB and 30 dB. There were no instances of perilymph gusher. In addition to an excluded case that was not reconstructed because of facial nerve position, 3 of the included patients were found to have a dehiscent facial nerve at surgery. There were no facial nerve injuries, and fixation of the malleus or incus was not found in any of the included patients. When hearing outcomes were compared with our results for otosclerosis over the same time period, rates of closure to within 10 dB and 20 dB were significantly worse in the congenital group. CONCLUSION: Closure of the air-bone gap in this population differs from our results in stapedectomy done for otosclerosis. This difference likely reflects subtle anatomic variations in the congenital group that affect the effectiveness of the prosthesis. Despite the difference in results, stapedectomy for congenital fixation remains an effective method to achieve significant hearing improvement in the majority of patients. EBM RATING: B-3b.

Adolescent↗

Avoiding pitfalls in surgery of the neck, parapharyngeal space, and infratemporal fossa.

The region of the upper neck, parapharyngeal space, and infratemporal fossa contains many vital structures in a confined area. Access is often limited, making surgical treatment challenging. Preoperative assessment is critical in determining the optimal surgical approach. In spite of improvements in preoperative evaluation and surgical techniques, sequelae from surgical therapy are sometimes unavoidable. Awareness of the potential problems is necessary to counsel patients appropriately regarding treatment options and all potential risks.

Carotid Body Tumor↗

Stapedectomy outcomes: titanium versus teflon wire prosthesis.

OBJECTIVE: To compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis. STUDY DESIGN: Retrospective chart review. METHODS: Titanium and Teflon wire stapes prostheses were compared with regard to effectiveness in closing the air-bone gap. The charts of 461 stapedectomies performed by one surgeon from 1996 to 2001 were reviewed. Patients who underwent stapedectomy for reasons other than otosclerosis, revision cases, and those with inadequate preoperative or postoperative bone-conduction threshold data were excluded. Small fenestra technique using either laser or drill was used for all patients. Inclusion criteria were met by 218 patients. Patients were then grouped according to type of prosthesis used, and hearing outcomes were compared. Measured outcomes were four frequency air-bone gap closure, pure-tone threshold, and rate of sensorineural hearing loss (SNHL). RESULTS: The study group was comprised of 35 titanium and 183 Teflon wire prostheses. Closure of the air-bone gap to less than 10 dB was achieved in 86% of the patients with Teflon prosthesis compared with 71% of those with titanium prostheses. The groups were equivalent in regard to site of otosclerotic disease as well as technique, laser or drill, used to create the fenestra. Rate of SNHL was low for both groups and not significantly different. CONCLUSIONS: Both prostheses provided comparable results, although the Teflon platinum wire prosthesis was slightly superior. The smaller numbers in the titanium group may confound these results. The design of the titanium prosthesis provides a crimp that is circumferential around the incus, and that prosthesis was selected in cases with a narrow incus. The selection bias may also influence the results seen in this study.

Adolescent↗

Resorption rate and biocompatibility characteristics of two polyester ventilation tubes in a guinea pig model.

OBJECTIVES: Determine the resorption rate and biocompatibility characteristics of 2 polyester ventilation tubes, and to determine whether soap and water exposure accelerates polyester tube degradation. STUDY DESIGN AND SETTING: 50/50 poly (D, L-lactide-co-glycolide; PLGA-50) and poly (L-lactide; PLA) polymers were placed into the tympanic membranes of Hartley pigmented guinea pigs. Integrity of the tubes was determined by weekly otoscopic examination. Biocompatibility was assessed by comparing auditory brainstem response (ABR) thresholds and by examining tympanic membrane changes following tube resorption. Shah minigrommet ventilation tubes were used as controls. In the second portion of this study, implanted PLGA-50 and PLA tubes were exposed weekly to a mixture of soap and water (1:5) until complete resorption was observed. Biocompatibility was assessed by periodic ABR testing and tympanic membrane examination. RESULTS: The PLA tubes remained in the tympanic membrane for a longer period (63.2 +/- 19.3 days) than the PLGA-50 (18.8 +/- 8.1 days). The tympanic membrane and resorbable tube interface demonstrated equivalent findings for auditory thresholds and tissue histopathology at the implant site compared to nonresorbable controls. The resorption behavior was not altered by exposure to soap and water. Tympanic membranes of all animals following tube degradation and soap water exposure were intact with minimal scarring and no signs of persistent foreign body response. The histological analysis showed that implantation of resorbable tubes was not accompanied by secondary infection with otorrhea through the tube, did not result in a permanent perforation or dislocation of the tube into the middle ear cavity, and was not followed by excess tympanosclerosis or localized or diffuse membrane atrophy. CONCLUSIONS AND SIGNIFICANCE: Resorbable polyester pressure equalization tubes demonstrate predictable resorption behavior and similar biocompatibility characteristics when compared with nonresorbable Shah minigrommet ventilation tubes. Exposure to soap water does not accelerate polyester tube degradation nor change the host tissue response during the indwelling period or after complete resorption. The data suggests that resorbable ventilation tubes are substantially equivalent to other FDA-approved tympanostomy devices with regard to safety and biocompatibility in the guinea pig model examined and may provide improved clinical performance by combining this approach with sustained release technology. EBM RATING: B-2.

Animals↗