PubMed Health⌕ Search

Biomedical subjects

Belkis Valdman

Publications and source records attributed to Belkis Valdman.

3 recordsLinked to original sources

A sequential enzymatic microreactor system for ethanol detection of gasohol mixtures.

A sequential enzymatic double microreactor system with dilution line was developed for quantifying ethanol from gasohol mixtures, using a colorimetric detection method, as a new proposal to the single micro reactor system used in previous work. Alcohol oxidase (AOD) and horseradish peroxidase (HRP) immobilized on glass beads, one in each microreactor, were used with phenol and 4-aminophenazone and the red-colored product was detected with a spectrophotometer at 555 nm. Good results were obtained with the immobilization technique used for both AOD and HRP enzymes, with best retention efficiencies of 95.3 +/- 2.3% and 63.2 +/- 7.0%, respectively. The two microreactors were used to analyze extracted ethanol from gasohol blends in the range 1-30 % v/v (10.0-238.9 g ethanol/L), with and without an on-line dilution sampling line. A calibration curve was obtained in the range 0.0034-0.087 g ethanol/L working with the on-line dilution integrated to the biosensor FIA system proposed. The diluted sample concentrations were also determined by gas chromatography (GC) and high-pressure liquid chromatography (HPLC) methods and the results compared with the proposed sequential system measurements. The effect of the number of analysis performed with the same system was also investigated.

Alcohol Oxidoreductases↗

Development and application of an integrated system for monitoring ethanol content of fuels.

An automated flow injection analysis (FIA) system for quantifying ethanol was developed using alcohol oxidase, horseradish peroxidase, 4-amino-phenazone, and phenol. A colorimetric detection method was developed using two different methods of analysis, with free and immobilized enzymes. The system with free enzymes permitted analysis of standard ethanol solution in a range of 0.05-1.0 g of ethanol/L without external dilution, a sampling frequency of 15 analyses/h, and relative SD of 3.5%. A new system was designed consisting of a microreactor with a 0.91-mL internal volume filled with alcohol oxidase immobilized on glass beads and an addition of free peroxidase, adapted in an FIA line, for continued reuse. This integrated biosensor-FIA system is being used for quality control of biofuels, gasohol, and hydrated ethanol. The FIA system integrated with the microreactor showed a calibration curve in the range of 0.05-1.5 g of ethanol/L, and good results were obtained compared with the ethanol content measured by high-performance liquid chromatography and gas chromatography standard methods.

Alcohol Oxidoreductases↗

Model based soft-sensor for on-line determination of substrate.

A software sensor for on-line determination of substrate was developed based on a model for fed-batch alcoholic fermentation process and on-line measured signals of ethanol, biomass, and feed flow. The ethanol and biomass signals were obtained using a colorimetric biosensor and an optical sensor developed in previous works that permitted determination of ethanol at a concentration of 0-40 g/L and biomass of 0-60 g/L. The volume in the fermentor could be continuously calculated using the total measured signal of the feed flow. The results obtained show that the model used is adequate for the proposed software sensor and determines continuously the substrate concentration with efficiency and security during the fermentation process.

Alcohols↗