Clinical implementation of MOSFET detectors for dosimetry in electron beams.

BACKGROUND AND PURPOSE: To determine the factors converting the reading of a MOSFET detector placed on the patient's skin without additional build-up to the dose at the depth of dose maximum (D(max)) and investigate their feasibility for in vivo dose measurements in electron beams. MATERIALS AND METHODS: Factors were determined to relate the reading of a MOSFET detector to D(max) for 4 - 15 MeV electron beams in reference conditions. The influence of variation in field size, SSD, angle and field shape on the MOSFET reading, obtained without additional build-up, was evaluated using 4, 8 and 15 MeV beams and compared to ionisation chamber data at the depth of dose maximum (z(max)). Patient entrance in vivo measurements included 40 patients, mostly treated for breast tumours. The MOSFET reading, converted to D(max), was compared to the dose prescribed at this depth. RESULTS: The factors to convert MOSFET reading to D(max) vary between 1.33 and 1.20 for the 4 and 15 MeV beams, respectively. The SSD correction factor is approximately 8% for a change in SSD from 95 to 100 cm, and 2% for each 5-cm increment above 100 cm SSD. A correction for fields having sides smaller than 6 cm and for irregular field shape is also recommended. For fields up to 20 x 20 cm(2) and for oblique incidence up to 45 degrees, a correction is not necessary. Patient measurements demonstrated deviations from the prescribed dose with a mean difference of -0.7% and a standard deviation of 2.9%. CONCLUSION: Performing dose measurements with MOSFET detectors placed on the patient's skin without additional build-up is a well suited technique for routine dose verification in electron beams, when applying the appropriate conversion and correction factors.

Breast Neoplasms↗

Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment.

PURPOSE: To quantify the effect of set-up errors and respiratory motion on dose distributions for non-small cell lung cancer (NSCLC) treatment. METHODS AND MATERIALS: Irradiations of 5 NSCLC patients were planned with 3 techniques, two (conformal radiation therapy (CRT) and intensity modulated radiation therapy (IMRT1)) with a homogeneous dose in the planning target volume (PTV) and a third (IMRT2) with dose heterogeneity. Set-up errors were simulated for gross target volume (GTV) and organs at risk (OARs). For the GTV, the respiration was also simulated with a periodical motion around a varying average. Two configurations were studied for the breathing motion, to describe the situations of free-breathing (FB) and respiration-correlated (RC) CT scans, each with 2 amplitudes (5 and 10 mm), thus resulting in 4 scenarios (FB_5, FB_10, RC_5 and RC_10). Five thousand treatment courses were simulated, producing probability distributions for the dosimetric parameters. RESULTS: For CRT and IMRT1, RC_5, RC_10 and FB_5 were associated with a small degradation of the GTV coverage. IMRT2 with FB_10 showed the largest deterioration of the GTV dosimetric indices, reaching 7% for Dmin at the 95% probability level. Removing the systematic error due to the periodic breathing motion was advantageous for a 10 mm respiration amplitude. The estimated probability of radiation pneumonitis and acute complication for the esophagus showed limited sensitivity to geometrical uncertainties. Dmax in the spinal cord and the parameters predicting the risk of late esophageal toxicity were associated to a probability up to 50% of violating the dose tolerances. CONCLUSIONS: Simulating the effect of geometrical uncertainties on the individual patient plan should become part of the standard pre-treatment verification procedure.

Carcinoma, Non-Small-Cell Lung↗

Intensity-modulated radiotherapy of breast cancer using direct aperture optimization.

BACKGROUND AND PURPOSE: To design a clinically reliable and efficient step-and-shoot IMRT delivery technique for the treatment of breast cancer using direct aperture optimization (DAO). Using DAO, segments are created and optimized within the same optimization process. PATIENTS AND METHODS: The DAO technique implemented in the Pinnacle treatment planning system, which is called direct machine parameter optimization (DMPO), was used to generate IMRT plans for twelve breast cancer patients. The prescribed dose was 50 Gy. Two DMPO plans were generated. The first approach uses DMPO only; the second technique combines DMPO with two predefined segments (DMPO(segm)), having shapes identical to the conventional tangential fields. The weight of these predefined segments is optimized simultaneously with DMPO. The DMPO plans were compared with normal two-step (TS) IMRT, creating segments after optimizing the intensity. RESULTS: Dose homogeneity within the target volume was 4.8+/-0.6, 4.3+/-0.5 and 3.8+/-0.5 Gy for the TS, DMPO and DMPO(segm) plans, respectively. Comparing the IMRT plans with an idealized dose distribution obtained using only beamlet optimization, the degradation of the dose distribution was less for the DMPO plans compared with the two-step IMRT approach. Furthermore, this degradation was similar for all patients, while for the two-step IMRT approach it was patient specific. CONCLUSIONS: An efficient step-and-shoot IMRT solution was developed for the treatment of breast cancer using DMPO combined with two predefined segments.

Algorithms↗

Anatomy changes in radiotherapy detected using portal imaging.

BACKGROUND AND PURPOSE: Localisation images normally acquired to verify patient positioning also contain information about the patient's internal anatomy. The aim of this study was to investigate the anatomical changes observed in localisation images and examples of dosimetric consequences. PATIENTS AND METHODS: Localisation images were obtained weekly prior to radiotherapy with an electronic portal imaging device (EPID). A series of 'difference images' was created by subtracting the first localisation image from that of subsequent fractions. Images from 81 lung, 40 head and neck and 34 prostate cancer patients were classified according to the changes observed. Changes were considered relevant if the average pixel value over an area of at least 1cm(2) differed by more than 5%, to allow for variations in linac output and EPID signal. Two patients were selected to illustrate the dosimetric effects of relevant changes. Their plans were re-calculated with repeat CT scans acquired after 4 weeks of treatment and compared with the difference images of the corresponding days. RESULTS: Progressive changes were detected for 57% of lung and 37% of head and neck cancer patients studied. Random changes were observed in 37% of lung, 28% of head and neck and 82% of prostate cancer patients. For a lung case, an increase of 10.0% in EPID dose due to tumour shrinkage corresponded to an increase of 9.8% in mean lung dose. Gas pockets in the rectum region of the prostate case increased the EPID dose by 6.3%, and resulted in a decrease of the minimum dose to the planning target volume of 26.4%. CONCLUSIONS: Difference images are an efficient means of qualitatively detecting anatomical changes for various treatment sites in clinical practice. They can be used to identify changes for a particular patient, to indicate if the dose delivered to the patient would differ from planning and to detect if there is a need for re-planning.

Diagnostic Imaging↗

Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.

The use of electronic portal imaging devices (EPIDs) is a promising method for the dosimetric verification of external beam, megavoltage radiation therapy-both pretreatment and in vivo. In this study, a previously developed EPID back-projection algorithm was modified for IMRT techniques and applied to an amorphous silicon EPID. By using this back-projection algorithm, two-dimensional dose distributions inside a phantom or patient are reconstructed from portal images. The model requires the primary dose component at the position of the EPID. A parametrized description of the lateral scatter within the imager was obtained from measurements with an ionization chamber in a miniphantom. In addition to point dose measurements on the central axis of square fields of different size, we also used dose profiles of those fields as reference input data for our model. This yielded a better description of the lateral scatter within the EPID, which resulted in a higher accuracy in the back-projected, two-dimensional dose distributions. The accuracy of our approach was tested for pretreatment verification of a five-field IMRT plan for the treatment of prostate cancer. Each field had between six and eight segments and was evaluated by comparing the back-projected, two-dimensional EPID dose distribution with a film measurement inside a homogeneous slab phantom. For this purpose, the y-evaluation method was used with a dose-difference criterion of 2% of dose maximum and a distance-to-agreement criterion of 2 mm. Excellent agreement was found between EPID and film measurements for each field, both in the central part of the beam and in the penumbra and low-dose regions. It can be concluded that our modified algorithm is able to accurately predict the dose in the midplane of a homogeneous slab phantom. For pretreatment IMRT plan verification, EPID dosimetry is a reliable and potentially fast tool to check the absolute dose in two dimensions inside a phantom for individual IMRT fields. Film measurements inside a phantom can therefore be replaced by EPID measurements.

Algorithms↗

A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images.

The verification of intensity-modulated radiation therapy (IMRT) is necessary for adequate quality control of the treatment. Pretreatment verification may trace the possible differences between the planned dose and the actual dose delivered to the patient. To estimate the impact of differences between planned and delivered photon beams, a three-dimensional (3-D) dose verification method has been developed that reconstructs the dose inside a phantom. The pretreatment procedure is based on portal dose images measured with an electronic portal imaging device (EPID) of the separate beams, without the phantom in the beam and a 3-D dose calculation engine based on the Monte Carlo calculation. Measured gray scale portal images are converted into portal dose images. From these images the lateral scattered dose in the EPID is subtracted and the image is converted into energy fluence. Subsequently, a phase-space distribution is sampled from the energy fluence and a 3-D dose calculation in a phantom is started based on a Monte Carlo dose engine. The reconstruction model is compared to film and ionization chamber measurements for various field sizes. The reconstruction algorithm is also tested for an IMRT plan using 10 MV photons delivered to a phantom and measured using films at several depths in the phantom. Depth dose curves for both 6 and 10 MV photons are reconstructed with a maximum error generally smaller than 1% at depths larger than the buildup region, and smaller than 2% for the off-axis profiles, excluding the penumbra region. The absolute dose values are reconstructed to within 1.5% for square field sizes ranging from 5 to 20 cm width. For the IMRT plan, the dose was reconstructed and compared to the dose distribution with film using the gamma evaluation, with a 3% and 3 mm criterion. 99% of the pixels inside the irradiated field had a gamma value smaller than one. The absolute dose at the isocenter agreed to within 1% with the dose measured with an ionization chamber. It can be concluded that our new dose reconstruction algorithm is able to reconstruct the 3-D dose distribution in phantoms with a high accuracy. This result is obtained by combining portal dose images measured prior to treatment with an accurate dose calculation engine.

Algorithms↗

Dose heterogeneity in the target volume and intensity-modulated radiotherapy to escalate the dose in the treatment of non-small-cell lung cancer.

PURPOSE: To quantify the dose escalation achievable in the treatment of non-small-cell lung cancer (NSCLC) by allowing dose heterogeneity in the target volume or using intensity-modulated radiotherapy (IMRT), or both. METHODS AND MATERIALS: Computed tomography data and contours of 10 NSCLC patients with limited movements of the tumor and representing a broad spectrum of clinical cases were selected for this study. Four irradiation techniques were compared: two conformal (CRT) and two IMRT techniques, either prescribing a homogeneous dose in the planning target volume (PTV) (CRT(hom) and IMRT(hom)) or allowing dose heterogeneity (CRT(inhom) and IMRT(inhom)). The dose heterogeneity was allowed only toward high doses, i.e., the minimum dose in the target for CRT(inhom) and IMRT(inhom) could not be lower than for the corresponding homogeneous plan. The dose in the PTV was escalated (fraction size of 2.25 Gy) until either an organ at risk reached the maximum allowed dose or the mean PTV dose reached a maximum level set at 101.25 Gy. RESULTS: When small and convex tumors were irradiated, CRT(hom) could achieve the maximum dose of 101.25 Gy, whereas for bigger and/or concave PTVs the dose level achievable with CRT(hom) was significantly lower, in 1 case even below 60 Gy. The CRT(inhom) allowed on average a 6% dose escalation with respect to CRT(hom). The IMRT(hom) achieved in all except 1 case a mean PTV dose of at least 75 Gy. The gain in mean PTV dose of IMRT(hom) with respect to CRT(hom) ranged from 7.7 to 14.8 Gy and the IMRT(hom) plans were always more conformal than the corresponding CRT(hom) plans. The IMRT(inhom) provided an additional advantage over IMRT(hom) of at least 5 Gy. For all CRT plans the achievable dose was determined by the lung dose threshold, whereas for more than half of the IMRT plans the esophagus was the dose-limiting organ. The IMRT plans were deliverable with 10-12 segments per beam and did not produce an increase of lung volume irradiated at low doses (<20 Gy). CONCLUSIONS: The dose in NSCLC treatments can be escalated by loosening the constraints on maximum dose in the target volume or using IMRT, or both. For large and concave tumors, an average dose escalation of 6% and 17% was possible when dose heterogeneity and IMRT were applied alone. When they were combined, the average dose increase was as high as 35%. Intensity-modulated RT delivered in a static mode can produce homogeneous dose distributions in the target and does not lead to an increase of lung volume receiving (very) low doses, even down to 5 Gy.

Carcinoma, Non-Small-Cell Lung↗

The sensitivity of dose distributions for organ motion and set-up uncertainties in prostate IMRT.

BACKGROUND AND PURPOSE: To determine the effect of organ motion and set-up uncertainties on IMRT dose distributions for prostate. METHODS: For five patients, IMRT techniques were designed to irradiate the CTV (prostate plus seminal vesicles). Technique I delivered 78 Gy to PTV1 (CTV+10 mm margin). Technique II delivered 68 Gy to PTV1, and a 10 Gy boost to PTV2 (CTV+an anisotropic margin of 0 to 5 mm). Technique III delivered 68 Gy to PTV1 and simultaneously 78 Gy to PTV2. Uncertainties were simulated using population statistics of organ motion and set-up accuracy. The average TCP (TCPpop) of the CTV and average NTCP (NTCPpop) of the rectal wall were calculated. RESULTS: The planning TCP was a good predictor for TCPpop for Techniques I and II. Technique III was sensitive for geometrical uncertainties, reducing TCPpop by 0.8 to 2.4% compared to planning. NTCPpop was reduced for Technique III by a factor 2.6 compared to Technique I. For all plans, the planning NTCP was strongly correlated with NTCPpop. CONCLUSIONS: Dose distributions created with Techniques I and II are insensitive for geometrical uncertainties, while Technique III resulted in a reduction of TCPpop. This reduction can be compensated by a small dose escalation, while still resulting in an NTCPpop of the rectal wall that is lower or comparable to Technique I.

Humans↗

An inter-centre quality assurance network for IMRT verification: results of the ESTRO QUASIMODO project.

BACKGROUND AND PURPOSE: IMRT necessitates extension of existing inter-centre quality assurance programs due to its increased complexity. We assessed the feasibility of an inter-centre verification method for different IMRT techniques. MATERIALS AND METHODS: Eight European radiotherapy institutions of the QUASIMODO network, have designed an IMRT plan for a horseshoe-shaped PTV surrounding a cylindrical OAR in a simplified pelvic phantom. All centres applied common plan objectives but used their own equipment for planning and delivery. They verified the delivery of this plan according to a common protocol with radiographic film and ionisation chamber measurements. The irradiated films, the results of the ionisation chamber measurements and the computed dose distributions were sent to one analysis centre that compared the measured and computed dose distributions with the gamma method and composite dose-area histograms. RESULTS: 4% (relative to the prescribed dose) and 3mm (distance-to-agreement) were decided feasible gamma criteria. The composite dose-area histograms showed a maximum local deviation of 3.5% in the mean dose of the PTV and 5% in the OAR. Systematic differences could be identified, and in some cases explained. CONCLUSIONS: This multi-centre dosimetric verification study demonstrated both the feasibility of a multi-centre quality assurance network to evaluate any IMRT planning and delivery system combination, as well as the validity of the methodology involved.

Community Networks↗

IMRT treatment planning:- a comparative inter-system and inter-centre planning exercise of the ESTRO QUASIMODO group.

BACKGROUND AND PURPOSE: The purpose of this work was a comparison of realistic IMRT plans based on the same CT-image data set and a common predefined set of dose objectives for the planning target volume and the organs at risk. This work was part of the larger European QUASIMODO IMRT verification project. MATERIALS AND METHODS: Eleven IMRT plans were produced by nine different European groups, each applying a representative set of clinically used IMRT treatment planning systems. The plans produced were to be deliverable in a clinically acceptable treatment time with the local technical equipment. All plans were characterized using a set of different quality measures such as dose-volume histograms, number of monitor units and treatment time. RESULTS: Only one plan was able to fulfil all dose objectives strictly; six plans failed some of the objectives but were still considered to be clinically acceptable; four plans were not able to reach the objectives. Additional quality scores such as the number of monitor units and treatment time showed large variations, which mainly depend on the delivery technique. CONCLUSION: The presented planning study showed that with nearly all presently available IMRT planning and delivery systems comparable dose distributions could be achieved if the planning goals are clearly defined in advance.

Anthropometry↗

Simplified intensity-modulated radiotherapy using pre-defined segments to reduce cardiac complications in left-sided breast cancer.

BACKGROUND AND PURPOSE: Left-sided breast cancer patients pose a difficult clinical challenge when significant heart and contralateral breast irradiation are present, particularly with tangential uniform beams. The aims of the study are: (1) to design and evaluate a simplified intensity-modulated radiotherapy (IMRT) (SI) solution using pre-defined segments, (2) to compare the SI technique with a conformal (CN) and a full fluence IMRT (FI) approach using two sets of beam orientations, clinical (-C) and optimal (-O), and (3) to quantify the benefits of treatment technique and beam orientation. PATIENTS AND METHODS: Nine left-sided breast cancer patients with a maximum heart distance of at least 2.0 cm were planned using three different techniques and two different beam orientations. All three techniques were planned using clinical orientations (i.e. CN-C, FI-C and SI-C). Two techniques were planned using more optimal orientations (i.e. FI-O and SI-O). Dose-volume histograms and radiobiologic modelling are used for plan evaluation. RESULTS: The average mean planning target volume (PTV) doses are 91.6+/-4.5, 98.4+/-6.3, 102.0+/-8.7, 100.0+/-5.9 and 103.9+/-8.3% for the CN-C, FI-C, SI-C, FI-O and SI-O plans, respectively. The average normal tissue complication probabilities for late excess cardiac mortality are 2.1+/-0.6, 0.2+/-0.1, 0.2+/-0.1, 0.1+/-0.0 and 0.1+/-0.0%, respectively. For a given beam orientation, FI plans are the best and CN plans are the worst. The dose distributions for the SI-C and FI-C plans are almost identical with significant heart sparing but at a cost of some target underdosage. The dose distributions are better conformed around the PTV with more optimal beam orientations, resulting in better sparing of adjacent organs at risk. FI-C plans are inferior to SI-O plans. CONCLUSIONS: For clinical uniform two-beam orientations, significant heart sparing is possible with the addition of intensity modulation but at the expense of worsening target coverage. Simplified IMRT can, for all intents, be substituted for full IMRT with clinical beam orientations. Applying more optimal non-uniform beam orientations improves PTV coverage while maintaining significant heart sparing but increases the PTV dose heterogeneity.

Breast↗

Sensitivity of treatment plan optimisation for prostate cancer using the equivalent uniform dose (EUD) with respect to the rectal wall volume parameter.

BACKGROUND AND PURPOSE: To analyse the sensitivity of plan optimisation of prostate cancer treatments with respect to changes in the volume parameter (n), when the EUD is used to control the dose in the rectal wall. PATIENTS AND METHODS: A series of plans was defined, by varying n over a range between 0.08 and 1, and testing different cost functions and beam arrangements. In all cases, the aim was to minimise the EUD in the rectal wall, while ensuring specific dose coverage of the PTV, and limiting the dose in the other OARs. The results were evaluated in terms of 3-D dose distribution and with respect to the current clinical knowledge about late rectal toxicity after irradiation. RESULTS: Different values of n lead to very similar dose distributions over the PTV (differences in mean dose < 1 Gy, differences in dose given to 99% of the volume < 1%). For the rectal wall, the following observations were made: (a) all cumulative DVH curves crossed each other around 60 Gy; (b) the rectal wall volume receiving doses between 30 and 45 Gy could change by 45 and 30%, respectively, depending on the value of n; (c) for doses higher than 70Gy the differences were typically within 5%. Different values of n also affected the position of isodose surfaces. The distance between the 70 and the 30 Gy isodose curves changed in the AP direction by a factor of 3 when n decreased from 1 to 0.08. High values of n were associated with less dose conformity and a larger volume (at least 20%) of normal tissues receiving 50 Gy or more. All DVHs for the rectal wall were below published dose toxicity thresholds except when the prescribed dose was escalated up to 86 Gy. CONCLUSIONS: In most cases, the solutions associated with n values up to 0.25 produced similar dose distribution in the rectal wall for doses above 45 Gy, complying with the dose-toxicity thresholds we analysed. The choice of a specific value of n in the optimisation requires an analysis of its effects on the dose distribution for the rectal wall, but also on other aspects, such as the value of the dose to the non-involved normal tissues.

Aged↗

Determining optimal two-beam axial orientations for heart sparing in left-sided breast cancer patients.

BACKGROUND AND PURPOSE: The optimal intensity fluence profile of a beam depends on the profiles of other beams but most optimizations assume fixed beam orientations, a priori. Breast cancer radiotherapy attempts to cover the target and to spare critical structures such as the heart and lungs. The study aims are (1) to determine and document the optimal two-beam orientation that best spares the heart for left-sided breast cancer patients and (2) to investigate the influence of the treatment technique (i.e., conformal versus intensity modulation) on the optimal objective cost function. MATERIAL AND METHODS: Ten left-sided breast cancer patients were planned using a conformal (3DCRT) and a simplified intensity modulated (sIMRT) technique using predefined segments and different two-beam orientations. Optimal segment weights were determined exhaustively for all axial two-beam combinations, in 5 degree increments, by minimizing a quadratic objective cost function. The resulting objective cost function was analyzed with respect to target geometry and treatment technique. RESULTS: The sIMRT plans are generally less sensitive to beam orientation compared to 3DCRT plans. Optimal two-beam orientations for 3DCRT and sIMRT plans exist and they correspond to a hinge angle of approximately 188 degrees and 160 degrees or 210 degrees (the latter is bimodal), respectively. CONCLUSIONS: The optimization software is a useful tool that can test many different beam combinations and estimate their associated objective cost values. Afterwards, the most promising beam orientations could be re-optimized under the TPS to fine-tune and verify the dose distributions. Optimal uniform two-beam orientations for the breast consist of opposing tangential medial and lateral beams. Optimal nonuniform two-beam orientations for left-sided breast cancers are bimodal, containing hinge angles around 160 degrees and 210 degrees. Nonuniform beam techniques are less sensitive to beam orientation compared to uniform beam techniques and result in significantly improved heart sparing but at a cost of slightly compromised planning target volume coverage.

Breast↗

Comparison between manual and automatic segment generation in step-and-shoot IMRT of prostate cancer.

PURPOSE: To compare two methods to generate treatment plans for intensity-modulated radiotherapy (IMRT) of prostate cancer, delivered in a step-and-shoot mode. The first method uses fluence optimization (inverse planning) followed by conversion of the fluence weight map into a limited number of segments. In the second method, segments are manually assigned using a class solution (forward planning), followed by computer optimization of the segment weights. METHODS: Treatment plans for IMRT, utilizing a simultaneous integrated boost, were created. Plans comprise a five-field technique to deliver 78 Gy to the prostate plus seminal vesicles. Five patients were evaluated. Optimization objectives of both planning approaches concerned dose coverage of the target volumes and the dose distribution in the rectal wall. The two methods were evaluated by comparing dose distributions, the complexity of the resulting plan and the time expenditure to generate and to deliver the plan. RESULTS: For both planning approaches 99% of the target volumes received 95% of the prescribed dose, which complies with our planning objectives. Inverse planning resulted in more conformal dose distributions than forward planning (conformity index: 1.37 versus 1.51). Inverse planning reduced the dose to the rectal wall compared to a manually designed plan, albeit to a small extent. The theoretical probability of severe rectal proctitis and/or stenosis was reduced on average by 1.9% with inverse planning. Maximal sparing of the rectal wall was achieved with inverse planning for a patient whose target volume was partly wrapped around the rectum. The number of segments generated with inverse planning ranged between 33 and 52, and between 9 and 13 segments for manually created segments. CONCLUSION: Dose coverage of the planning target volumes is adequate for both approaches of planning. Inverse planning results in slightly better dose distributions with respect to the rectal wall compared to manual planning, at the cost of an increase of the number of segments by a factor of 3.

Humans↗

A comparison of forward and inverse treatment planning for intensity-modulated radiotherapy of head and neck cancer.

BACKGROUND AND PURPOSE: To compare intensity-modulated treatment plans of patients with head and neck cancer generated by forward and inverse planning. MATERIALS AND METHODS: Ten intensity-modulated treatment plans, planned and treated with a step&shoot technique using a forward planning approach, were retrospectively re-planned with an inverse planning algorithm. For this purpose, two strategies were applied. First, inverse planning was performed with the same beam directions as forward planning. In addition, nine equidistant, coplanar incidences were used. The main objective of the optimisation process was the sparing of the parotid glands beside an adequate treatment of the planning target volume (PTV). Inverse planning was performed both with pencil beam and Monte Carlo dose computation to investigate the influence of dose computation on the result of the optimisation. RESULTS: In most cases, both inverse planning strategies managed to improve the treatment plans distinctly due to a better target coverage, a better sparing of the parotid glands or both. A reduction of the mean dose by 3-11Gy for at least one of the parotid glands could be achieved for most of the patients. For three patients, inverse planning allowed to spare a parotid gland that had to be sacrificed by forward planning. Inverse planning increased the number of segments compared to forward planning by a factor of about 3; from 9-15 to 27-46. No significant differences for PTV and parotid glands between both inverse planning approaches were found. Also, the use of Monte Carlo instead of pencil beam dose computation did not influence the results significantly. CONCLUSION: The results demonstrate the potential of inverse planning to improve intensity-modulated treatment plans for head and neck cases compared to forward planning while retaining clinical utility in terms of treatment time and quality assurance.

Head and Neck Neoplasms↗

Importance of accurate dose calculations outside segment edges in intensity modulated radiotherapy treatment planning.

BACKGROUND AND PURPOSE: To assess the effect of differences in the calculation of the dose outside segment edges on the overall dose distribution and the optimisation process of intensity modulated radiation therapy (IMRT) treatment plans. PATIENTS AND METHODS: Accuracy of dose calculations of two treatment planning systems (TPS1 and TPS2) was assessed, to ensure that they are both suitable for IMRT treatment planning according to published guidelines. Successively, 10 treatment plans for patients with prostate and head and neck tumours were calculated in both systems. The calculations were compared in selected points as well as in combination with volumetric parameters concerning the planning target volume (PTV) and organs at risk. RESULTS: For both planning systems, the calculations agree within 2.0% or 3 mm with the measurements in the high-dose region for single and multiple segment dose distributions. The accuracy of the dose calculation is within the tolerances proposed by recent recommendations. Below 35% of the prescribed dose, TPS1 overestimates and TPS2 underestimates the measured dose values, TPS2 being closer to the experimental data. The differences between TPS1 and TPS2 in the calculation of the dose outside segments explain the differences (up to 50% of the local value) found in point dose comparisons. For the prostate plans, the discrepancies between the TPS do not translate into differences in PTV coverage, normal tissue complication probability (NTCP) values and results of the plan optimisation process. The dose-volume histograms (DVH) of the rectal wall differ below 60 Gy, thus affecting the plan optimisation if a cost function would operate in this dose region. For the head and neck cases, the two systems give different evaluations of the DVH points for the PTV (up to 22% differences in target coverage) and the parotid mean dose (1.0-3.0 Gy). Also the results of the optimisation are influenced by the choice of the dose calculation algorithm. CONCLUSIONS: In IMRT, the accuracy of the dose calculation outside segment edges is important for the determination of the dose to both organs at risks and target volumes and for a correct outcome of the optimisation process. This aspect should therefore be of major concern in the commissioning of a TPS intended for use in IMRT. Fulfilment of the accuracy criteria valid for conformal radiotherapy is not sufficient. Three-dimensional evaluation of the dose distribution is needed in order to assess the impact of dose calculation accuracy outside the segment edges on the total dose delivered to patients treated with IMRT.

Head and Neck Neoplasms↗

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue.

BACKGROUND AND PURPOSE: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. MATERIALS AND METHODS: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-path length (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, dose-volume histograms (DVHs), the mean lung dose (MLD) and the percentage of lung receiving >20 Gy (V20). Published dose-effect relations for local perfusion changes and radiation pneumonitis were re-evaluated. RESULTS: Evaluation of isodoses showed a consistent overestimation of the dose at the lung/tumor boundary by the EPL algorithm of about 10%. This overprediction of dose was also reflected in a consistent shift of the EPL DVHs for the lungs towards higher doses. The MLD, as determined by the EPL and CS algorithm, differed on average by 17+/-4.5% (+/-1SD). For V20, the average difference was 12+/-5.7% (+/-1SD). For both parameters, a strong correlation was found between the EPL and CS algorithms yielding a straightforward conversion procedure. Re-evaluation of the dose-effect relations showed that lung complications occur at a 12-14% lower dose. The values of the TD(50) parameter for local perfusion reduction and radiation pneumonitis changed from 60.5 and 34.1 Gy to 51.1 and 29.2 Gy, respectively. CONCLUSIONS: A simple tissue inhomogeneity-correction algorithm like the EPL overestimates the dose to normal lung tissue. Dosimetric parameters for lung injury (e.g. MLD, V20) computed using both algorithms are strongly correlated making an easy conversion feasible. Dose-effect relations should be refitted when more accurate dose data is available.

Algorithms↗

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63.

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for radiation oncology patients with high-Z hip prostheses.

Advisory Committees↗