PubMed Health⌕ Search

Biomedical subjects

Bengt Wittgren

Publications and source records attributed to Bengt Wittgren.

At least 19 recordsLinked to original sources

Programmed cross flow asymmetrical flow field-flow fractionation for the size separation of pullulans and hydroxypropyl cellulose.

Different functions for the programming of the cross flow in asymmetrical flow field-flow fractionation were studied with the aim to find the flow conditions most suitable for the molar mass distribution analysis of high molecular weight polysaccharides. A mixture of four differently sized pullulans covering the molar mass range 5.8 x 10(3)-1.6 x 10(6) g mol(-1) were used as a model sample. Two types of programs were studied, linear and exponential decays, both with and without initial periods of a constant cross flow. For comparison, nonprogrammed runs, i.e. using constant cross flow, were studied. It was found that exponentially decaying cross flow gave the most uniform molar mass selectivity across the fractogram. The programmed cross flow was applied to the molar mass distribution analysis of a technical quality of hydroxypropyl cellulose.

Cellulose↗

Characterization of chemical substitution of hydroxypropyl cellulose using enzymatic degradation.

The distribution of substituents along the polymer backbone will have a strong influence on the properties of modified cellulose. Endoglucanases were used to degrade a series of hydroxypropyl cellulose (HPC) derivatives with a high degree of substitution. The HPCs were characterized with cloud-point analysis prior to degradation. The extent of enzymatic degradation was determined with size-exclusion chromatography with online multi-angle light scattering and refractive index detection and also with high-pH anion exchange chromatography with pulsed amperometric detection. To further characterize the formed products, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was employed for analysis of short-chained oligosaccharides. The different endoglucanases showed varying degradation capability depending on structure of the active site. The highly substituted HPCs had different susceptibility to degradation by the endoglucanases. The results show a difference in substituent distribution between HPCs, which would explain the differing cloud-point behaviors. Increased number of regions with low substitution could be correlated with lower polymer cloud point. The study shows the usefulness of enzymatic degradation to study the distribution of substituents in soluble biopolymer derivates.

Bacterial Proteins↗

NMR, cloud-point measurements and enzymatic depolymerization: complementary tools to investigate substituent patterns in modified celluloses.

The substituent patterns of some chemically modified celluloses were characterized as a function of their size distribution, using size-exclusion chromatography coupled to both nuclear magnetic resonance spectroscopy (NMR) and cloud-point measurements. Intact and enzymatically hydrolyzed methyl cellulose (MC) was fractionated according to size, and the level of substitution of the fractions was measured off-line using NMR. Clouding behavior was also measured as a function of size. Clear differences between hydrolyzed and nonhydrolyzed samples were observed using both techniques. For samples that had been selectively hydrolyzed using cellulose-degrading enzymes, NMR data showed a direct link between the degree of degradation and the level of substitution. Differences in the clouding behavior highlighted changes in substituent levels and substituent patterns across the size distribution. The techniques gave valuable and somewhat complementary information on the substituent distributions of the samples before and after enzymatic hydrolysis.

Bacillus↗

Substituent distribution and clouding behavior of hydroxypropyl methyl cellulose analyzed using enzymatic degradation.

The distribution of substituents along the polymer backbone will have a strong influence on the properties of modified cellulose. Endoglucanases were used to degrade three different batches of hydroxypropyl methyl cellulose (HPMC) derivatives with similar chemical properties. The phase separation of the HPMCs as a function of temperature, i.e., the clouding behavior, was analyzed prior to degradation. The total amount of unsubstituted glucose was determined using total acid hydrolysis followed by high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD). The products after enzymatic degradation were analyzed with size-exclusion chromatography with online multiangle light scattering and refractive index detection and also with reducing end determination. To further characterize the formed products, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was employed for analysis of short-chained oligosaccharides. The different endoglucanases showed varying degradation capability of HPMC derivatives, depending on structure of the active site. The investigated HPMCs had different susceptibility to degradation by the endoglucanases. The results showed a difference in substituent distribution between HPMC batches, which could explain the differing clouding behaviors. The batch with the lowest cloud point was shown to contain a higher number of non-degradable, highly substituted regions.

Cellulase↗

Interactions between sodium dodecyl sulphate and non-ionic cellulose derivatives studied by size exclusion chromatography with online multi-angle light scattering and refractometric detection.

The novel approach described allows to characterise the surfactant-polymer interaction under several sodium dodecyl sulphate (SDS) concentrations (0-20 mM) using size exclusion chromatography (SEC) with online multi-angle light scattering (MALS) and refractometric (RI) detection. Three different cellulose derivatives, hydroxypropyl cellulose (HPC), hydroxypropyl methyl cellulose (HPMC) and hydroxyethyl cellulose (HEC), have been studied in solution containing 10 mM NaCl and various concentrations of sodium dodecyl sulphate. It is shown that this approach is well suited for successful application of both Hummel-Dreyer and multi-component light scattering principles and yields reliable molecular masses of both the polymer complex and the polymer itself within the complex, the amount of surfactant bound into the complex as well as appropriate values of the refractive index increment (dn/dc)micro, of both the complex and the polymer in question. The more hydrophobic derivatives HPC and HPMC adsorbed significantly more SDS than HEC. The inter-chain interactions close to critical aggregation concentration (cac) were clearly seen for HPC and HPMC as an almost two-fold average increase in polymer molecular mass contained in the complex.

Cellulose↗

Molecular information on the dissolution of polydisperse polymers: Mixtures of long and short poly(ethylene oxide).

A systematic study of the dissolution of dry, polydisperse poly(ethylene oxide) (PEO) samples, obtained from mixtures of low-molecular-weight and high-molecular-weight PEO, was made. During the dissolution process, the individual release of the low- and high-molecular-weight fractions was monitored. The high-molecular-weight/low-molecular-weight ratio controls the release rate, and the fraction of high-molecular-weight polymers dominates the effect on the overall release rate in mixed PEO tablets. Both fractions are released at the same rate during the main part of the dissolution process; however, during the initial dissolution period a fractionation occurs. The release rate is not a unique function of the average molecular weight of the polymer, but also depends on the polydispersity. By contrast, the average dimension of a polymer coil, as given by the intrinsic viscosity, gives a good prediction of the release rate irrespective of the polydispersity or details of the molecular weight distribution.

Molecular Weight↗

Derivatization using dimethylamine for tandem mass spectrometric structure analysis of enzymatically and acidically depolymerized methyl cellulose.

Structure analysis of partially depolymerized methyl cellulose was performed by nanoelectrospray ionization tandem mass spectrometry (nano-ESI-MS/MS) and by matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS). Dimethylamine (DMA) was used for the first time as a reducing end derivatization reagent for oligosaccharides. This is an attractive reagent since it could be easily removed from the reaction mixture. Most important it also introduces a basic functional group that increased the sensitivity in both MALDI and nano-ESI. Depolymerization was made in two ways: one by the cellulose selective endoglucanase 5A from Bacillus agaradhaerens (Ba Cel5A) and the other by trifluoroacetic acid. The DMA derivatives formed both protonated and sodiated molecules in nano-ESI and MALDI. Tandem MS of protonated molecules yielded predominantly Y fragments from which the distribution of the substituents in the oligomers could be measured. Fragments obtained in tandem MS of sodiated molecules provided information regarding the positions of the substituents within the anhydroglucose units (AGUs). It was found that Ba Cel5A could cleave glucosidic bonds also if the AGU on the reducing side of the bond was fully methylated. The combination of DMA derivatization and tandem MS was demonstrated as a tool for the characterization of endoglucanase selectivity.

Cellulase↗

Distribution analysis of ultra-high molecular mass poly(ethylene oxide) containing silica particles by size-exclusion chromatography with dual light-scattering and refractometric detection.

Two different size-exclusion chromatography (SEC) systems, connected in-line either to a low-angle light scattering (LALS) or to a multiangle light scattering (MALS) detector, are employed for determination of molecular mass distributions (MMD) of poly(ethylene oxide) (PEO) samples having a weight average molecular mass up to eight millions. The detrimental effect of the presence of strongly scattering silica particles in the samples on the light scattering signal can be eliminated using a suitable sample dissolution procedure utilizing silica solubility in aqueous mobile phase. The selection of flow-rate and sample concentration have a large impact on the obtained results. Hydrodynamic retardation phenomena and nonlinearity effects are shown to introduce severe errors in the molecular mass distributions unless flow-rate and sample concentration are kept at sufficiently low levels. Self-compensating ability of the dual detection in flow-rate effects is shown to be the main advantage here. A good agreement between the results obtained using LALS and MALS detection is found provided that a carefully selected angular extrapolation procedure is used in the case of MALS data. Thus, using carefully selected experimental conditions, SEC with light-scattering (LS) and refractometric detection proved to be an efficient technique for MMD characterisation also of ultra-high molecular mass (UHM) PEO polymers.

Chromatography, Gel↗

Tuning the polymer release from hydrophilic matrix tablets by mixing short and long matrix polymers.

In this work a rotating disc method was developed for studying the dissolution process of "bimodal" polymer tablets, whose dissolution rates have been tuned by mixing low-molecular weight and high-molecular weight samples of poly(ethylene oxide) in various proportions. The tablets were prepared along different routes, by mixing the polymer fractions as powders or by mixing on a molecular level so that the effect of tablet heterogeneity could be assessed, but also by purifying the original powders so the effect of additives could be determined. When the mixed tablet was dominated by the low-molecular weight fraction, a faster dissolution was observed for the tablet mixed at the powder level. In those cases small gel pieces were released from the tablet during the whole dissolution process. As long as no gel piece erosion was observed, it did not matter if the two polymer fractions were blended on the molecular level or on the powder level, the steady-state dissolution rate was the same. The presence of small amounts of additives in the nonpurified commercial samples had no significant effect on the tablet dissolution within the uncertainty of the experiment.

Calorimetry, Differential Scanning↗

Improved matrix-assisted laser desorption/ionisation sample preparation of a partially depolymerised cellulose derivative by continuous spray deposition and interfacing with size-exclusion chromatography.

Continuous spray deposition (CSD) of aqueous solutions of partially depolymerised methyl cellulose was found to improve matrix-assisted laser desorption/ionisation (MALDI) sample preparation. One feature was that the sensitivity in MALDI time-of-flight mass spectrometry increased up to an order of magnitude compared with the standard sample preparation method. Another feature was that CSD provided targets for MALDI with homogeneously distributed analyte. This resulted in a more even signal intensity and a higher reproducibility than in the standard method. High-mass discrimination was more pronounced in CSD than in the standard method. Size-exclusion chromatography with aqueous eluent was coupled online to CSD onto matrix-precoated foils. The suitability for determination of the molar mass distribution of methyl cellulose was investigated.

Biopolymers↗

Analytical approaches to improved characterization of substitution in hydroxypropyl cellulose.

Chemical characterization of cellulose derivatives is of high importance as it provides information about the often inhomogeneous substitution that may seriously affect the properties of these polymers in various applications. A detailed mapping of the chemical structure of these derivatives requires several advanced techniques to be employed. In this study, the average substitution and the substitution heterogeneity in two hydroxypropyl cellulose (HPC) samples from different suppliers were studied by means of NMR spectroscopy, MALDI-TOF MS, and HPAEC-PAD. (1)H and (13)C NMR provided information on the molar substitution, a parameter that could be analyzed by MALDI-TOF MS as well. In addition, the latter technique was used for determination of the distribution of the number of hydroxypropyl groups per glucose unit present in the two polymers. The heterogeneity of the substitution was studied by determining the amount of unsubstituted glucose units in the HPC samples, which was accomplished by HPAEC-PAD analysis. The results obtained suggest that the two HPC samples differ in both hydroxypropoxy content and distribution of the hydroxypropyl groups. Further, the benefits and importance of employing several analytical methods when investigating the cellulose ether substitution are demonstrated, as each method provides different kinds of information on the chemical content.

Carbohydrate Sequence↗

Accuracy in multiangle light scattering measurements for molar mass and radius estimations. Model calculations and experiments.

Multiangle light scattering (MALS) is a well-established technique used to determine the size of macromolecules and particles. In this study, different extrapolation procedures used in MALS were investigated with regard to accuracy and robustness in the obtained molar mass and rms radius. Three different mathematical transformations of the light scattering function referred to as the Debye, Zimm, and Berry methods for constructing the Debye plot were investigated for two idealized polymer shapes, homogeneous spheres and random coils, with radii from 25 to 250 nm. The effect of the angular interval used for the extrapolation was investigated, as was the robustness of the different transformations toward errors in the measured light scattering intensity at low angles. For an rms radius less than 50 nm, the relative error in molar mass due to extrapolation was less than 1% independent of the method used. For larger radii, the error increased and the extrapolation procedure became more critical. For random coil polymers, the Berry method was superior in terms of accuracy and robustness. For spheres, the Debye method was superior. The Zimm method was inferior to the others. The different extrapolation methods were evaluated and compared on experimental data from a size exclusion chromatography-MALS analysis of an ultrahigh molar mass poly(ethylene oxide) (PEO). The PEO data qualitatively verified the calculations and stressed the importance of optimizing the extrapolation procedure after careful evaluation of the experimental data. A discussion of how to detect erroneous data in an experimental Debye plot is given.

Journal Article↗

Molar mass characterization of cationic methyl methacrylate-ethyl acrylate copolymers using size-exclusion chromatography with online multi-angle light scattering and refractometric detection.

Size-exclusion chromatography (SEC) combined with online multi-angle light scattering (MALS) and refractometric (RI) detection has been employed for the molar mass characterisation of water-insoluble cationic methyl methacrylate-ethyl acrylate copolymers (Eudragit RS and RL). Due to their positive charge, cationic polymers are particularly difficult to separate on a SEC column, in worst cases being completely adsorbed on the oppositely charged packing material. This work has examined how a careful addition of salt (LiCl) to the copolymer solution in ethanol decreases the electrostatic interactions, clearly seen as a decrease in elution volume from the SEC column as well as an improved recovery. At a certain level of ionic strength, typically about 50 mM, the copolymer recovery from the SEC column reached 100% and molar mass distributions corresponding to the complete sample could be obtained. The combined MALS/RI detection gives the opportunity to measure the absolute molar mass independent of recovery and retention. Thus, in this study, it turned out to be a favourable tool for tracing the changes in elution behaviour of the charged copolymer as the ionic strength was increased.

Acrylates↗

Development of a size exclusion chromatography method for the determination of molar mass for poloxamers.

An aqueous size exclusion chromatography (SEC) method for determination of the molar mass of poloxamers 188 and 407 has been developed as an alternative to the pharmacopoeia methods. During the development work two different columns and several different eluent compositions were investigated. With a PL-aquagel-OH column, non-exclusion behaviour was obtained. A TSKgel column gave good separation of both poloxamers. The best separation was obtained with an eluent consisting of sodium chloride (0.01 M)-methanol (90:10, v/v) on the TSKgel column. The method was shown to be linear within the elution time of the two poloxamers and to have acceptable precision. The results from the SEC method was compared to results obtained using SEC with online multi angle light scattering detection (MALS) and to results obtained with matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS).

Chromatography, Gel↗

Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry of partially depolymerised carboxymethyl cellulose.

Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) of partially depolymerised carboxymethyl cellulose (CMC) have been investigated. The depolymerisation was either enzymatic or acidic. Fractions of enzymatically depolymerised CMC were collected from size-exclusion chromatography (SEC) and further investigated by MALDI-TOFMS. 2,5-Dihydroxybenzoic acid was used as matrix, dissolved in H(2)O due to the poor solubility of CMC in suitable organic solvents. The samples were dried by two methods, in ambient atmosphere and at reduced pressure. Under reduced pressure the sample spot homogeneity increased. This drying method, however, produced additional adduct peaks in the mass spectra originating from ion exchange on the CMC oligomers. Analysis of CMC could be performed in both negative and positive ion modes. Mass discrimination and variation in ionisation efficiency were demonstrated by comparing mass spectra with SEC data. Measurements of the degree of substitution (DS) were performed on three CMCs with different DS values, which were depolymerised in trifluoroacetic acid. The three CMCs were easily distinguished from one another, but the obtained DS values deviated from the values supplied by the manufacturer.

Artifacts↗

Sample preparation effects in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry of partially depolymerised methyl cellulose.

Methyl cellulose (MC) was partially depolymerised and the oligomers thus obtained were studied by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The depolymerisation was either enzymatic or acidic. Fractions of enzymatically depolymerised MC were collected from size-exclusion chromatography and subjected to a sample preparation investigation. Several MALDI matrices and solvents were evaluated. The results showed that the solvent choice had a significant effect on the measured degree of substitution (DS). Aprotic solvents produced higher DS values, which was most likely due to poor solubility of species with low DS. The obtained signal intensity, however, did not correlate with the solubility but seemed to be more dependent on certain matrix/solvent combinations. All the matrices attempted produced mass spectra with sufficient signal intensity for accurate peak area calculation. The choice of matrix did not have any significant effect on the measured DS. Sample spots obtained from organic solvents had a more homogeneous distribution of the analyte and smaller crystals than those obtained from water. This increased both the reproducibility and peak resolution and in addition the analysis time was shorter. DS measurements were performed on two acidically depolymerised MCs with different nominal DS values. It was easy to distinguish between the two MCs, and the measured DS values agreed well with the values supplied by the manufacturers.

Biopolymers↗

Molecular mass distribution analysis of ethyl(hydroxyethyl)cellulose by size-exclusion chromatography with dual light-scattering and refractometric detection.

Dual low-angle light scattering and refractometric detection coupled to size-exclusion chromatography provided proof for the presence of a low amount of stable aggregates/particles in ethyl(hydroxyethyl)cellulose. Unlike the correct size-exclusion chromatographic behavior of the parent polysaccharide itself, the aggregates exhibit variable size-dependent weak retention as a function of flow-rate and of ionic strength of the aqueous mobile phase. Therefore, determination of the molecular mass of non-aggregated polymer is possible in aqueous mobile phase containing 0.1 M NaCl under conditions at which aggregates are completely adsorbed on the column packing irrespective of the flow-rate used. Flow-rate and ionic strength-dependent variations of aggregate behavior as well as model size-exclusion experiments with latex particles indicate that they partly carry a minute charge and have a compact structure. Their weak retention under the separation conditions used suggests a difference in their surface chemistry when compared with the dissolved polymer coils which exhibit a correct size-exclusion behavior.

Cellulose↗

Enzymatic degradation of carboxymethyl cellulose hydrolyzed by the endoglucanases Cel5A, Cel7B, and Cel45A from Humicola insolens and Cel7B, Cel12A and Cel45Acore from Trichoderma reesei.

Enzymatic hydrolysis of carboxymethyl cellulose (CMC) has been studied with purified endoglucanases Hi Cel5A (EG II), Hi Cel7B (EG I), and Hi Cel45A (EG V) from Humicola insolens, and Tr Cel7B (EG I), Tr Cel12A (EG III), and Tr Cel45Acore (EG V) from Trichoderma reesei. The CMC, with a degree of substitution (DS) of 0.7, was hydrolyzed with a single enzyme until no further hydrolysis was observed. The hydrolysates were analyzed for production of substituted and non-substituted oligosaccharides with size exclusion chromatography (SEC) and with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF-MS). Production of reducing ends and of nonsubstituted oligosaccharides was determined as well. The two most effective endoglucanases for CMC hydrolysis were Hi Cel5A and Tr Cel7B. These enzymes degraded CMC to lower molar mass fragments compared with the other endoglucanases. The products had the highest DS determined by MALDI-TOF-MS. Thus, Hi Cel5A and Tr Cel7B were less inhibited by the substituents than the other endoglucanases. The endoglucanase with clearly the lowest activity on CMC was Tr Cel45Acore. It produced less than half of the amount of reducing ends compared to Tr Cel7B; furthermore, the products had significantly lower DS. By MALDI-TOF-MS, oligosaccharides with different degree of polymerization (DP) and with different number of substituents could be separated and identified. The average oligosaccharide DS as function of DP could be measured for each enzyme after hydrolysis. The combination of techniques for analysis of product formation gave information on average length of unsubstituted blocks of CMC.

Ascomycota↗