PubMed Health⌕ Search

Biomedical subjects

Benjamin E Bierbaum

Publications and source records attributed to Benjamin E Bierbaum.

7 recordsLinked to original sources

Effect of preoperative exercise on measures of functional status in men and women undergoing total hip and knee arthroplasty.

OBJECTIVE: To evaluate the effect of a short preoperative exercise intervention on the functional status, pain, and muscle strength of patients before and after total joint arthroplasty. METHODS: A total of 108 men and women scheduled for total hip arthroplasty (THA) or total knee arthroplasty (TKA) were randomized to a 6-week exercise or education (control) intervention immediately prior to surgery. We assessed outcomes through questionnaires and performance measures. Analyses examined differences between groups over the preoperative and immediate postoperative periods and at 8 and 26 weeks postsurgery. RESULTS: Among THA patients, the exercise intervention was associated with improvements in preoperative Western Ontario and McMaster Universities Osteoarthritis Index function score (improvement of 2.2 in exercisers versus decline of 3.9 in controls; P = 0.02) and Short Form 36 physical function score (decline of 0.4 in exercisers versus decline of 14.3 in controls; P = 0.003). No significant differences were seen in TKA patients. Exercise participation increased muscle strength preoperatively (18% in THA patients and 20% in TKA patients), whereas the control patients had essentially no change in strength (P > 0.05 for exercise versus education in both THA and TKA groups). Exercise participation prior to total joint arthroplasty substantially reduced the risk of discharge to a rehabilitation facility in THA and TKA patients (adjusted odds ratio 0.27, 95% confidence interval 0.074-0.998). The intervention had no effects on outcomes 8 and 26 weeks postoperatively. CONCLUSION: A 6-week presurgical exercise program can safely improve preoperative functional status and muscle strength levels in persons undergoing THA. Additionally, exercise participation prior to total joint arthroplasty dramatically reduces the odds of inpatient rehabilitation.

Aged↗

The role played by cell-substrate interactions in the pathogenesis of osteoclast-mediated peri-implant osteolysis.

Prosthetic wear debris-induced peri-implant osteolysis is a major cause of aseptic loosening after total joint replacement. In this condition, wear particles released from the implant components induce a granulomatous inflammatory reaction at the interface between implant and adjacent bone, leading to progressive bone resorption and loss of fixation. The present study was undertaken to characterize definitively the phenotype of osteoclast-like cells associated with regions of peri-implant focal bone resorption and to compare the phenotypic features of these cells with those of mononucleated and multinucleated cells associated with polyethylene wear particles. Peri-implant tissues were obtained from patients undergoing hip revision surgery for aseptic loosening after total joint replacement. Cells were examined for the expression of several markers associated with the osteoclast phenotype using immunohistochemistry, histochemistry, and/or in situ hybridization. CD68 protein, a marker expressed by multiple macrophage lineage cell types, was detected in mononucleated and multinucleated cells associated with polyethylene particles and the bone surface. Cathepsin K and tartrate-resistant acid phosphatase were expressed highly in both mononucleated and multinucleated cells associated with the bone surface. Levels of expression were much lower in cells associated with polyethylene particles. High levels of beta3 integrin protein were detected in cells in contact with bone. Multinucleated cells associated with polyethylene particles exhibited faint positive staining. Calcitonin receptor mRNA expression was detected solely in multinucleated cells present in resorption lacunae on the bone surface and was absent in cells associated with polyethylene particles. Our findings provide further evidence that cells expressing the full repertoire of osteoclast phenotypic markers are involved in the pathogenesis of peri-implant osteolysis after total joint replacement. They also demonstrate that foreign body giant cells, although believed to be phenotypically and functionally distinct from osteoclasts, express many osteoclast-associated genes and gene products. However, the levels and patterns of expression of these genes in the two cell types differ. We speculate that, in addition to the role of cytokines and growth factors, the substrate with which these cells interact plays a critical role in their differential phenotypic and functional properties.

Acid Phosphatase↗

A mouse model of human breast cancer metastasis to human bone.

Currently, an in vivo model of human breast cancer metastasizing from the orthotopic site to bone does not exist, making it difficult to study the many steps of skeletal metastasis. Moreover, models used to identify the mechanisms by which breast cancer metastasizes to bone are limited to intracardiac injection, which seeds the cancer cells directly into the circulation, thus bypassing the early steps in the metastatic process. Such models do not reflect the full process of metastasis occurring in patients. We have developed an animal model of breast cancer metastasis in which the breast cancer cells and the bone target of osteotropic metastasis are both of human origin. The engrafted human bone is functional, based on finding human IgG in the mouse bloodstream, human B cells in the mouse spleen, and normal bone histology. Furthermore, orthotopic injection of a specific human breast cancer cell line, SUM1315 (derived from a metastatic nodule in a patient), later resulted in both bone and lung metastases. In the case of bone, metastasis was to the human implant and not the mouse skeleton, indicating a species-specific osteotropism. This model replicates the events observed in patients with breast cancer skeletal metastases and serves as a useful and relevant model for studying the disease.

Animals↗

Five-year experience with Crossfire highly cross-linked polyethylene.

UNLABELLED: Our purpose was to compare the clinical wear performance of highly cross-linked (Crossfire) polyethylene with conventional (N2Vac) polyethylene total hip bearings. We implanted 56 hips (47 patients) with Crossfire acetabular bearing liners and compared their wear performance with 53 conventional polyethylene inserts. Wear and clinical data were collected retrospectively at a minimum 4-year and average 5-year followup. The linear femoral head penetration rate measured from plain radiographs was 0.055 mm/year +/- 0.022 mm/year for the Crossfire polyethylene and 0.138 mm/year +/- 0.073 mm/year for the control, a reduction of 60% for the Crossfire components. Calculated annual wear was 0.036 mm/year for the Crossfire components and 0.131 mm/year for the controls, a reduction of 72%. Radiographic review at most recent followup showed a reduction in erosive osteolytic lesions of the proximal femur for the Crossfire components compared with controls, also suggesting a reduction in debris release for the Crossfire components. Complications leading to revision were not seen in the Crossfire or control groups. These clinical findings suggest that this particular highly cross-linked polyethylene can provide wear reduction and an alternate bearing surface for active patient populations. LEVEL OF EVIDENCE: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.

Aged↗

Ceramic-on-ceramic bearings in total hip arthroplasty.

The ideal bearing surface for total hip arthroplasty still is being sought. This bearing would be durable, cost-effective, easy to implant, inert, and produce minimal wear debris. Ceramic-on-ceramic bearings have continued to evolve and have enjoyed success in many European centers throughout the past 3 decades. A limited number of early reports from the United States discouraged widespread acceptance and use of ceramic-on-ceramic total hip arthroplasty. Once critically analyzed most of the failures from the early reports are attributable to design and material specific flaws. Vast improvements have been made in ceramic manufacturing leading to even more superior wear characteristics and higher burst strengths. The case for alumina-on-alumina ceramic bearings is becoming stronger as data accumulate clinically and in vitro. In a multicenter, prospective and randomized study, an alumina-on-alumina ceramic bearing is compared with a cobalt chrome-on-polyethylene bearing. After as many as 48 months there has been no significant difference in clinical performance between the two study groups. No ceramic head fracture or ceramic bearing failure has occurred. Therefore, this new alumina-on-alumina ceramic bearing is a safe option for total hip arthroplasty and may provide a more durable prosthesis especially in young and active patients.

Aluminum Oxide↗