Model-based compensation for quantitative 123I brain SPECT imaging.

Previously we have developed a model-based method that can accurately estimate downscatter contamination from high-energy photons in 123I imaging. In this work we combined the model-based method with iterative reconstruction-based compensations for other image-degrading factors such as attenuation, scatter, the collimator-detector response function (CDRF) and partial volume effects to form a comprehensive method for performing quantitative 123I SPECT image reconstruction. In the model-based downscatter estimation method, photon scatter inside the object was modelled using the effective source scatter estimation (ESSE) technique, including contributions from all the photon emissions. The CDRFs, including the penetration and scatter components due to the high-energy 123I photons, were estimated using Monte Carlo (MC) simulations of point sources in air at various distances from the face of the collimator. The downscatter contamination was then compensated for during the iterative reconstruction by adding the estimated results to the projection steps. The model-based downscatter compensation (MBDC) was evaluated using MC simulated and experimentally acquired projection data. From the MC simulation, we found about 39% of the total counts in the energy window of 123I were attributed to the downscatter contamination, which reduced image contrast and caused a 1.5% to 10% overestimation of activities in various brain structures. Model-based estimates of the downscatter contamination were in good agreement with the simulated data. Compensation using MBDC removed the contamination and improved the image contrast and quantitative accuracy to that of the images obtained from 159 keV photons. The errors in absolute quantitation were reduced to within +/-3.5%. The striatal specific binding potential calculated based on the activity ratio to the background was also improved after MBDC. The errors were reduced from -4.5% to -10.93% without compensation to -0.55% to 4.87% after compensation. The model-based method provided accurate downscatter estimation and, when combined with iterative reconstruction-based compensations, accurate quantitation was obtained with minimal loss of precision.

Brain↗

Three-class ROC analysis--a decision theoretic approach under the ideal observer framework.

Receiver operating characteristic (ROC) analysis is well established in the evaluation of systems involving binary classification tasks. However, medical tests often require distinguishing among more than two diagnostic alternatives. The goal of this work was to develop an ROC analysis method for three-class classification tasks. Based on decision theory, we developed a method for three-class ROC analysis. In this method, the objects were classified by making the decision that provided the maximal utility relative to the other two. By making assumptions about the magnitudes of the relative utilities of incorrect decisions, we found a decision model that maximized the expected utility of the decisions when using log-likelihood ratios as decision variables. This decision model consists of a two-dimensional decision plane with log likelihood ratios as the axes and a decision structure that separates the plane into three regions. Moving the decision structure over the decision plane, which corresponds to moving the decision threshold in two-class ROC analysis, and computing the true class 1, 2, and 3 fractions defined a three-class ROC surface. We have shown that the resulting three-class ROC surface shares many features with the two-class ROC curve; i.e., using the log likelihood ratios as the decision variables results in maximal expected utility of the decisions, and the optimal operating point for a given diagnostic setting (set of relative utilities and disease prevalences) lies on the surface. The volume under the three-class surface (VUS) serves as a figure-of-merit to evaluate different data acquisition systems or image processing and reconstruction methods when the assumed utility constraints are relevant.

Algorithms↗

Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models.

The four-dimensional (4-D) NURBS-based cardiac-torso (NCAT) phantom, which provides a realistic model of the normal human anatomy and cardiac and respiratory motions, is used in medical imaging research to evaluate and improve imaging devices and techniques, especially dynamic cardiac applications. One limitation of the phantom is that it lacks the ability to accurately simulate altered functions of the heart that result from cardiac pathologies such as coronary artery disease (CAD). The goal of this work was to enhance the 4-D NCAT phantom by incorporating a physiologically based, finite-element (FE) mechanical model of the left ventricle (LV) to simulate both normal and abnormal cardiac motions. The geometry of the FE mechanical model was based on gated high-resolution X-ray multislice computed tomography (MSCT) data of a healthy male subject. The myocardial wall was represented as a transversely isotropic hyperelastic material, with the fiber angle varying from -90 degrees at the epicardial surface, through 0 degrees at the midwall, to 90 degrees at the endocardial surface. A time-varying elastance model was used to simulate fiber contraction, and physiological intraventricular systolic pressure-time curves were applied to simulate the cardiac motion over the entire cardiac cycle. To demonstrate the ability of the FE mechanical model to accurately simulate the normal cardiac motion as well as the abnormal motions indicative of CAD, a normal case and two pathologic cases were simulated and analyzed. In the first pathologic model, a subendocardial anterior ischemic region was defined. A second model was created with a transmural ischemic region defined in the same location. The FE-based deformations were incorporated into the 4-D NCAT cardiac model through the control points that define the cardiac structures in the phantom which were set to move according to the predictions of the mechanical model. A simulation study was performed using the FE-NCAT combination to investigate how the differences in contractile function between the subendocardial and transmural infarcts manifest themselves in myocardial Single photon emission computed tomography (SPECT) images. The normal FE model produced strain distributions that were consistent with those reported in the literature and a motion consistent with that defined in the normal 4-D NCAT beating heart model based on tagged magnetic resonance imaging (MRI) data. The addition of a subendocardial ischemic region changed the average transmural circumferential strain from a contractile value of -0.09 to a tensile value of 0.02. The addition of a transmural ischemic region changed average circumferential strain to a value of 0.13, which is consistent with data reported in the literature. Model results demonstrated differences in contractile function between subendocardial and transmural infarcts and how these differences in function are documented in simulated myocardial SPECT images produced using the 4-D NCAT phantom. Compared with the original NCAT beating heart model, the FE mechanical model produced a more accurate simulation for the cardiac motion abnormalities. Such a model, when incorporated into the 4-D NCAT phantom, has great potential for use in cardiac imaging research. With its enhanced physiologically based cardiac model, the 4-D NCAT phantom can be used to simulate realistic, predictive imaging data of a patient population with varying whole-body anatomy and with varying healthy and diseased states of the heart that will provide a known truth from which to evaluate and improve existing and emerging 4-D imaging techniques used in the diagnosis of cardiac disease.

Algorithms↗

Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.

UNLABELLED: We evaluated the performance characteristics of the eXplore VISTA dual-ring small-animal PET scanner, a stationary, ring-type, depth-of-interaction (DOI) correcting system designed to simultaneously maximize sensitivity, resolution, and resolution uniformity over a field of view sufficient to image rodent-sized animals. METHODS: We measured the intrinsic spatial resolution response of the VISTA detector modules, spatial and volume resolution throughout a representative portion of the field of view, and imaged several common resolution phantoms to provide a qualitative picture of resolution performance. We obtained an axial sensitivity profile and measured central point source sensitivity, scatter fractions and noise equivalent count (NEC) rates for rat- and mouse-sized objects using different energy windows, and count rate linearity. In addition, we measured the energy and timing resolution of both of the crystal layers (cerium-doped gadolinium orthosilicate and cerium-doped lutetium-yttrium orthosilicate) that give VISTA machines a DOI compensation capability. We examined the effectiveness of this DOI compensation by comparing spatial resolution measurements with and without the DOI correction enabled. Finally, several animal studies were included to illustrate system performance in the field. RESULTS: Spatial and volume resolutions averaged approximately 1.4 mm and 2.9 mm(3), respectively (with 3-dimensional Fourier rebinning and 2-dimensional filtered backprojection image reconstructions and an energy window of 250-700 keV), along the central axis of the scanner, and the spatial resolution was better than 1.7 mm and 2.1 mm at 1 and 2 cm off the central axis, respectively. Central point source sensitivity measured approximately 4% with peak NEC rates of 126.8 kcps at 455 kBq/mL and 77.1 kcps at 141 kBq/mL for mouse- and rat-sized uniform, cylindric phantoms, respectively. The radial spatial resolution at 2.8 cm off axis with DOI compensation was 2.5 mm but degraded (by 56%) to 3.9 mm without DOI compensation (as would be the case with a geometrically identical scanner without DOI correction capability). CONCLUSION: These results indicate that the VISTA small-animal PET scanner is well suited to imaging rodent-sized animals. The combination of high spatial resolution, resolution uniformity, sensitivity, and count rate performance, made possible in part by the novel use of phoswich detector modules, confers significant technical advantages over machines with similar geometry but without DOI correction capability.

Algorithms↗

Dynamic imaging of allogeneic mesenchymal stem cells trafficking to myocardial infarction.

BACKGROUND: Recent results from animal studies suggest that stem cells may be able to home to sites of myocardial injury to assist in tissue regeneration. However, the histological interpretation of postmortem tissue, on which many of these studies are based, has recently been widely debated. METHODS AND RESULTS: With the use of the high sensitivity of a combined single-photon emission CT (SPECT)/CT scanner, the in vivo trafficking of allogeneic mesenchymal stem cells (MSCs) colabeled with a radiotracer and MR contrast agent to acute myocardial infarction was dynamically determined. Redistribution of the labeled MSCs after intravenous injection from initial localization in the lungs to nontarget organs such as the liver, kidney, and spleen was observed within 24 to 48 hours after injection. Focal and diffuse uptake of MSCs in the infarcted myocardium was already visible in SPECT/CT images in the first 24 hours after injection and persisted until 7 days after injection and was validated by tissue counts of radioactivity. In contrast, MRI was unable to demonstrate targeted cardiac localization of MSCs in part because of the lower sensitivity of MRI. CONCLUSIONS: Noninvasive radionuclide imaging is well suited to dynamically track the biodistribution and trafficking of mesenchymal stem cells to both target and nontarget organs.

Animals↗

Partial volume effect compensation for quantitative brain SPECT imaging.

Partial volume (PV) effects degrade the quantitative accuracy of SPECT brain images. In this paper, we extended a PV compensation (PVC) method originally developed for brain PET, the geometric transfer matrix (GTM) method, to brain SPECT using iterative reconstruction-based compensations. In the GTM method a linear transform between the true regional activities and the measured results was assumed. Elements of the GTM were calculated by projecting and reconstructing maps with uniform regions representing different structures. However, with iterative reconstruction methods, especially when reconstruction-based compensation for detector response was applied, we found that it was important to treat the region maps as a perturbation to the reconstructed image in the estimation of the GTM. This modified method, termed perturbation-based GTM (pGTM) was evaluated using Monte Carlo (MC) simulated and experimentally acquired data. Results showed great improvement of the quantitative accuracy in brain SPECT imaging. For MC simulated data, PVC using pGTM reduced the underestimation of striatal activities from 30% to less than 1.2%. For experimental data, PVC using pGTM reduced the underestimation of striatal activities from 36% to less than 7.8%. The underestimation of the striatum to background activity ratio was also improved from 31% to 2.7%.

Algorithms↗

Effect of attenuation correction on lesion detection using a hybrid PET system.

OBJECTIVE: The purpose of this study was to investigate the effect of attenuation correction (AC) on lesion detection for a hybrid PET system. MATERIAL AND METHOD: Experimental list-mode data were acquired from hot spheres inside a uniform cylindrical phantom with an elliptical cross-section using a Siemens E. CAM+ dual-camera hybrid PET system. Spheres with inner diameters of 0.8- and 1-cm and the cylindrical phantom were filled with F-18 to simulate lesions with lesion-to-background (L/B) ratios of 14:1 and 8:1, respectively, found in clinical PET studies. The list-mode data of each sphere size were regrouped into sinograms with peak-to-peak energy window settings at 30% and 20% for the 0.8- and 1-cm diameter lesion, respectively. They were then rebinned using the single slice rebinning method. Attenuation correction was applied assuming uniform attenuation. The sinograms with and without AC were reconstructed using 5 iterations of OS-EM algorithm with 8 angles/ subset and postfiltered with a Butterworth filter with n = 5 and fc = 0.52 cycles/cm. Human observer performance study and localization receiver operating characteristic (LROC) analysis were used to evaluate the reconstructed images for maximum lesion detection. Average areas under the LROC curves (A(LROC)) across 8 observers obtained with and without AC were determined. The null hypothesis that there was no difference between with AC and without AC was tested using a two-tailed t-test with 95% confidence interval. RESULTS: The results indicated that for the 0. 8-cm lesion with 14:1 L/B ratio, the A(LROC) decreases from 0.66 to 0.62 when AC is applied as compared to without AC andfrom 0.69 to 0.63 for the 1.0-cm lesion with 8:1 L/ B ratio, but no statistical significant difference (p > 0. 05). CONCLUSION: The authors conclude that for a phantom with hot lesions embedded in a uniform background, AC decreases lesion detectability compared to without AC using a hybrid PET system for small lesion sizes.

Humans↗

New devices for imaging in nuclear medicine.

Pinhole gamma camera imaging offers the ability to obtain high resolution images from single gamma ray emitting radiotracers playing a reasonable tradeoff between very small field of view (FoV) and sensitivity. On the other hand the total spatial resolution of a pinhole imaging device is predominantly affected by the detector intrinsic spatial resolution for reduced magnification factors. To design very compact pinhole SPET scanners with very high intrinsic spatial resolution, authors investigated a miniature gamma camera based on the newly developed Hamamatsu H8500 flat panel photomultiplier. The PSPMT was coupled to the following scintillation arrays: CsI(Tl) array with 0.2-mm, 1-mm, 1.4-mm pixel size and NaI (Tl) with 1-mm pixel size. The imaging performances were evaluated by 57Co spot and flood irradiations. NaI(Tl) array shows a better pixel identification for 1 mm pixel size, proving to be a good candidate to make a large area photodetector based on multi PSPMTs closely packed. Although CsI(Tl) array had the smallest pixel size, the low light output limited the best intrinsic spatial resolution to about 0.5 mm.

Gamma Cameras↗

Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

In this paper, we apply the channelized Hotelling observer (CHO) using a defect detection task to the optimization and evaluation of three-dimensional iterative reconstruction-based compensation methods for myocardial perfusion single-photon emission computed tomography (SPECT). We used a population of 24 mathematical cardiac-torso phantoms that realistically model the activity and attenuation distribution in three classes of patients: females, and males with flat diaphragms and raised diaphragms. Projection data were generated and subsequently reconstructed using methods based on the ordered subsets-expectation maximization (OSEM) algorithm. The methods evaluated included compensation for attenuation, detector response blurring, and scatter in various combinations. We applied the CHO to optimize the number of iterations for OSEM and the cutoff frequency and order of a three-dimensional postreconstruction Butterworth filter. Using the optimal parameters, we then compared the compensation methods. The index of comparison in these studies was the area under the receiver operating characteristics curve (AUC) for the CHO. We found that attenuation compensation with either detector response or scatter compensation gave statistically significant increases in the AUC compared to attenuation compensation alone. The greatest increase in the AUC occurred when all three compensations were applied. These results indicate that compensation for detector response and scatter, in addition to attenuation compensation, will improve defect detectability in myocardial SPECT images.

Algorithms↗

Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study.

UNLABELLED: Attenuation, photon scatter, and distance-dependent collimator-detector response are major degrading factors in myocardial SPECT images. The current study investigated whether compensation for these factors improves perfusion defect detectability, and compared the results for human observers with a previous study using a mathematical observer. METHODS: Four methods were investigated: attenuation compensation (AC); attenuation and detector response compensation; attenuation and scatter compensation; and attenuation, detector response, and scatter compensation (ADSC). For ADSC, 4 three-dimensional postreconstruction Butterworth filter cutoff frequencies were investigated for a pixel size of 0.62 cm: 0.12, 0.14, 0.16, and 0.22 pixel(-1). Five observers read images reconstructed using the 4 compensation methods. Receiver operating characteristics (ROC) analysis was used to determine the area under the ROC curve in each treatment studied. RESULTS: Reconstruction methods that incorporated scatter and detector response compensation had higher indices of detectability than AC alone. Over the range studied, a filter cutoff frequency of 0.14 pixel(-1) was optimal. A comparison of human observer results with an earlier channelized Hotelling observer study performed with the same images showed excellent agreement in trend and ranking of defect detectability. CONCLUSION: Compensation for detector response and scatter improves defect detectability compared with AC alone, although detectability may depend on phantom population choice and noise level. An optimal filter cutoff was found that is lower than what is typically used in a clinical setting. The channelized Hotelling observer is a good predictor of human observer performance and may reduce the need for tedious, time-consuming studies with human observers.

Area Under Curve↗

Development of a 4-D digital mouse phantom for molecular imaging research.

PURPOSE: We develop a realistic and flexible 4-D digital mouse phantom and investigate its usefulness in molecular imaging research. METHODS: Organ shapes were modeled with non-uniform rational B-spline (NURBS) surfaces based on high-resolution 3-D magnetic resonance microscopy (MRM) data. Cardiac and respiratory motions were modeled based on gated magnetic resonance imaging (MRI) data obtained from normal mice. Pilot simulation studies in single-photon emission computed tomography (SPECT) and X-ray computed tomography (CT) were performed to demonstrate the utility of the phantom. RESULTS: NURBS are an efficient and flexible way to accurately model the anatomy and cardiac and respiratory motions for a realistic 4-D digital mouse phantom. The phantom is capable of producing realistic molecular imaging data from which imaging devices and techniques can be evaluated. CONCLUSION: The phantom provides a unique and useful tool in molecular imaging research. It can be used in the development of new imaging instrumentation, image acquisition strategies, and image processing and reconstruction methods.

Animals↗

Comparison of 180 degrees and 360 degrees acquisition for myocardial perfusion SPECT with compensation for attenuation, detector response, and scatter: Monte Carlo and mathematical observer results.

BACKGROUND: The optimal projection data acquisition strategy for myocardial perfusion (MP) single photon emission computed tomography (SPECT) remains controversial. METHODS: We compared MP SPECT using 180 degrees and 360 degrees projection data obtained with the same acquisition time, reconstructed either with filtered back projection (FBP) or the iterative ordered-subsets expectation maximization (OS-EM) algorithm with various combinations of attenuation, detector response, and scatter compensation using mathematical observers and a myocardial defect detection task. We used Monte Carlo-simulated projection data from a population of 3-dimensional nurbs-based cardiac-torso (NCAT) phantoms with ranges of variability in patient anatomy, organ uptake, defect location, defect size, and noise level based on clinical data. Projection data from 180 degrees and 360 degrees acquisitions were generated by assuming the same acquisition time. After iterative or FBP reconstruction, standard postprocessing methods were applied. For each acquisition and reconstruction method, we optimized the number of iterations and cut-off frequency of the Butterworth filter using the Channelized Hotelling Observer methodology. The optimum set of parameters was that which gave the maximum area under the curve. RESULTS: For both acquisition protocols, OS-EM with compensations provided better performance than FBP or OS-EM without compensation. For FBP, the optimized 180 degrees acquisition provided a statistically significant increase in AUC as compared with optimized 360 degrees acquisition. For OS-EM, the AUCs for 180 degrees were slightly larger than for 360 degrees acquisitions when comparing images reconstructed with the same compensations. However, the differences were smaller and not statistically significant. CONCLUSION: With optimized reconstruction and filtering parameters, 180 degrees acquisition provided a statistically significant improvement over 360 degrees acquisition for FBP reconstruction. However, for OS-EM the differences were small and not statistically significant.

Algorithms↗