PubMed Health⌕ Search

Biomedical subjects

Benno Willke

Publications and source records attributed to Benno Willke.

4 recordsLinked to original sources

Measurement of a low-absorption sample of OH-reduced fused silica.

Low-absorption optics made of OH-reduced fused silica are a key technology for future gravitational wave detectors such as the Advanced LIGO. We developed a sensitive method to measure the absorption inside the beam splitter of the GEO 600, taking advantage of the effect of thermal lensing. Using this method, we derived a bulk absorption of less than 0.25 ppm/cm for a piece of Suprasil 311 SV at a wavelength of 1064 nm. To the best of our knowledge, this is the lowest value of light absorption inside fused silica reported so far in the literature.

Journal Article↗

Laser power stabilization for second-generation gravitational wave detectors.

We present results on the power stabilization of a Nd:YAG laser in the frequency band from 1 Hz to 100 kHz. High-power, low-noise photodetectors are used in a dc-coupled control loop to achieve relative power fluctuations down to 5 x 10(-9) Hz(-1/2) at 10 Hz and 3.5 x 10(-9) Hz(-1/2) up to several kHz, which is very close to the shot-noise limit for 80 mA of detected photocurrent on each detector. We investigated and eliminated several noise sources such as ground loops and beam pointing. The achieved stability level is close to the requirements for the Advanced LIGO gravitational wave detector.

Journal Article↗

Simultaneously suppressing frequency and intensity noise in a Nd:YAG nonplanar ring oscillator by means of the current-lock technique.

We show that frequency and intensity noise in a Nd:YAG laser are correlated to a high degree and can be traced to the same underlying cause, namely, power fluctuations of the pump source. Because of this correlation, simultaneous suppression of frequency and intensity noise by 30 dB is achieved by means of a single actuator, the pump power.

Journal Article↗

Automatic beam alignment for the mode-cleaner cavities of GEO 600.

The automatic alignment system for the two suspended, triangular mode-cleaner cavities of the gravitational wave detector GEO 600 has been in continuous operation since the spring of 2001. A total of 20 angular degrees of freedom are controlled by feedback loops with almost no manual alignment having been required since installation. Error signals for the eight most important degrees of freedom are obtained with the differential wave-front sensing technique. We describe the sensing system, the control topology, and the performance of the automatic alignment system. A continuous locking stretch of more than 120 h has been achieved.

Journal Article↗