PubMed Health⌕ Search

Biomedical subjects

Bernard F Morrey

Publications and source records attributed to Bernard F Morrey.

At least 37 records · Page 2Linked to original sources

Distal humeral fractures treated with noncustom total elbow replacement.

BACKGROUND: The purpose of this study was to review the cases of patients with a distal humeral fracture that was treated with a noncustom total elbow arthroplasty. We hypothesized that, on the basis of the functional and clinical outcome, total elbow replacement is a reliable option for the treatment of elderly patients with a severe, comminuted fracture of the distal part of the humerus. METHODS: We retrospectively reviewed forty-nine acute distal humeral fractures in forty-eight patients who were treated with total elbow arthroplasty as the primary option. The average age of the patients was sixty-seven years. Forty-three fractures were followed for at least two years. According to the AO classification, five fractures were type A, five were type B, and thirty-three were type C. The average age of the forty-three patients was sixty-nine years and the average duration of follow-up was seven years. Fourteen patients died during the review period. Postoperative clinical function was assessed with use of the Mayo elbow performance score, and anteroposterior and lateral radiographs made at follow-up examinations were reviewed. RESULTS: At the latest follow-up examination, the average flexion arc was 24 degrees (range, 0 degrees to 75 degrees ) to 131 degrees (range, 100 degrees to 150 degrees ) and the Mayo elbow performance score averaged 93 of a possible 100 points. Heterotopic ossification was present to some extent in seven elbows, with radiographic abutment noted in two. Thirty-two (65%) of the forty-nine elbows had neither a complication nor any further surgery from the time of the index arthroplasty to the most recent follow-up evaluation. Fourteen elbows (29%) had a single complication, and most of them did not require further surgery. Ten additional procedures, including five revision arthroplasties, were required in nine elbows; five were related to soft tissue and five were related to the implant or bone. CONCLUSIONS: Complex distal humeral fractures should be assessed primarily for the reliability with which they can be reconstructed with osteosynthesis. When osteosynthesis is not considered to be feasible, especially in patients who are physiologically older and place lower demands on the joint, total elbow arthroplasty can be considered. This retrospective review supports a recommendation for total elbow arthroplasty for the treatment of an acute distal humeral fracture when strict inclusion criteria are observed.

Adult↗

Medial collateral ligament strain with partial posteromedial olecranon resection. A biomechanical study.

BACKGROUND: Partial resection of the posteromedial aspect of the olecranon in the treatment of valgus extension impingement osteophytosis is a well-described technique. It has been hypothesized that removal of the normal olecranon process, beyond the osteophytic margin, increases the strain in the anterior bundle of the medial collateral ligament. METHODS: We used an electromagnetic tracking device to investigate the strain in the anterior bundle of the medial collateral ligament as a function of increasing applied torque and posteromedial resections of the olecranon in seven cadaveric elbows. Applied torques under valgus stress consisted of hand weight, hand weight plus 1.75 Nm, and hand weight plus 3.5 Nm. Resections were conducted in sequential 3-mm increments, from 0 to 9 mm. We measured changes in the length of the anterior and posterior bands of the anterior bundle of the medial collateral ligament with strain gauges. The strains of the two bands were averaged, and the average was reported. RESULTS: The strain in the anterior bundle of the medial collateral ligament was found to increase with increasing flexion angle, valgus torque, and olecranon resection beyond 3 mm. In two elbows, the anterior bundle of the medial collateral ligament ruptured during testing following the 9-mm resection. There was a significant difference between the strain following the 6-mm resection and that following the 3-mm resection at 110 degrees of flexion with 3.5 Nm of added torque (p = 0.004). CONCLUSIONS: In this in vitro cadaver study, an increase in flexion angle, an increase in valgus torque, and resection of > or =6 mm led to an increase in strain in the anterior bundle of the medial collateral ligament. The non-uniform change in strain related to 3 mm of resection suggests that resections of the posteromedial aspect of the olecranon of >3 mm may jeopardize the function of the anterior bundle.

Aged↗

Total knee arthroplasty for neuropathic (Charcot) joints.

The clinical and radiographic results of 40 modern design condylar total knee arthroplasties (TKAs) in 29 patients with a confirmed diagnosis of Charcot joint were reviewed. The followup averaged 7.9 years (range, 2-15 years) for clinical and 6.4 years (range, 2-15) for radiographic surveillance. There was a significant improvement in Knee Society pain and function scores and ROM after knee arthroplasty. Extensive bone fragmentation and bone defect was present in 38 knees (95%). Metal wedge augments (10 knees, eight patient), autologous bone grafting (17 knees, 13 patients), and bone allografts (two knees, two patients) were used to reinforce the bony defects. Ligamentous instability necessitated the use of long stem components in 27 knees and rotating hinge prostheses in five knees. There were six reoperations for periprosthetic fracture (two knees, two patients), aseptic loosening (two knees, two patients), instability (one knee, one patient), and deep infection (one knee, one patient). Total knee arthroplasty may be offered to a select group of patients with end-stage neuropathic arthropathy. The basic principles of knee arthroplasty in restoring limb alignment, reinforcing bony defects by bone grafting or augmented prostheses, careful ligamentous balancing, and appropriate selection of constrained prostheses particularly are important in these patients. The technical challenges encountered during TKA in patients with neuropathic arthropathy, particularly in those with significant deformities, can require skills, implant systems, and methods usually reserved for complex revision arthroplasty.

Adult↗

Insall Award paper. Primary TKA in patients with lymphedema.

Lymphedema is a relatively common disorder; wound and vascular complications after orthopaedic surgery are assumed, but not previously shown, to be higher in this population. We reviewed the outcome and complications of knee arthroplasty in patients with lymphedema, documented by physical examination at their preoperative medical assessment. This was a retrospective analysis of prospectively collected data compiled on all patients having knee arthroplasty at our institution. Eighty-three knee replacements were implanted in 63 patients. Patients were followed up for a minimum of 2 years, with a mean followup of 58 months (range, 24-228 months). No patients were lost to followup. We noted significant improvement in the Knee Society score from a preoperative mean of 47 points (range, 16-75 points) to a postoperative mean of 87 points (range, 53-100 points). The knee functional score also improved significantly from a preoperative mean of 36 points (range, 0-80 points), to a postoperative mean of 59 points (range, 0-100 points). The total complication rate was 31%, with 10 superficial wound infections (12%), six deep infections (7%), and three deep venous thromboses (3.6%). We concluded that although knee arthroplasty can be successful in reducing pain and improving function in patients with lymphedema, the complication rate is greater than that seen in patients without this diagnosis.

Aged↗

Validity of index of suspicion for pulmonary embolism after hip arthroplasty.

Pulmonary embolism after total hip arthroplasty is problematic, and intravenous heparin treatment in the absence of pulmonary embolism carries risk. Algorithms for treating pulmonary embolism often cite clinical index of suspicion as a basis for initiating intravenous heparin, but most information regarding variables to predict pulmonary embolism originate from studies of patients rather than only from patients who had arthroplasty. We studied the hypothesis that a more homogenous subpopulation, patients who had total hip arthroplasty, may have findings more accurately predictive of pulmonary embolism. One hundred fifty records of patients who had total hip arthroplasty who were suspected of having pulmonary embolism and who were evaluated for pulmonary embolism were assessed. Complaints, physical findings, heparinization status, and test results were analyzed with univariate and multivariate assessments to determine predictors of pulmonary embolism. No significant differences were found between patients with or without pulmonary embolism regarding subjective complaints, physical examination, blood gas results, electrocardiogram findings, radiographs of the chest, and imaging of the veins of the legs. All attempts to model these variables into an index of suspicion that accurately predicted pulmonary embolism were unsuccessful. We advise adherence to established treatment algorithms rather than clinical suspicion when deciding whether to initiate heparin therapy.

Aged↗

Surgical treatment of distal triceps ruptures.

BACKGROUND: Distal triceps tendon ruptures occur rarely, and the diagnosis is often missed when the injury is acute. The literature provides little guidance regarding treatment or the outcome of treatment of these injuries. The goal of this report was to present our experience with the diagnosis, timing and technique of surgical treatment, and outcome of treatment of distal triceps tendon ruptures in twenty-two patients. None of the ruptures followed joint replacement. METHODS: Twenty-three procedures were performed in twenty-two patients with an average age of forty-seven years. The average duration of follow-up was ninety-three months (range, seven to 264 months). Data were obtained by a retrospective review of records and radiographs before and after surgery. Also, thirteen patients returned for follow-up and were examined clinically. Six additional patients responded to a telephone questionnaire. One patient was lost to follow-up, and two had died. Formal biomechanical evaluation of isokinetic strength and isokinetic work was performed in eight patients, at an average of eighty-eight months after surgery. Isokinetic strength data were available from the charts of two additional patients. RESULTS: Ten of the triceps tendon ruptures were initially misdiagnosed. At the time of diagnosis, triceps weakness with a decreased active range of motion was found in most patients, and a palpable defect in the tendon was noted after sixteen ruptures. Operative findings revealed a complete tendon rupture in eight cases and partial injuries in fifteen. Fourteen primary repairs and nine reconstructions of various types were performed. Three of the primary repairs were followed by rerupture. At the time of follow-up, the range of elbow motion averaged 10 degrees to 136 degrees. All but two elbows had a functional range of motion; however, the lack of a functional range in the two elbows was probably due to posttraumatic arthritis and not to the triceps tendon rupture. Triceps strength was noted to be 4/5 or 5/5 on manual testing in all examined subjects. Isokinetic testing of ten patients showed that peak strength was, on the average, 82% of that of the untreated extremity. Testing showed the average endurance of the involved extremity to be 99% of that of the uninvolved arm. The results after repair and reconstruction were comparable, but the patients' recovery was slower after reconstruction. CONCLUSIONS: The diagnosis of distal triceps tendon rupture is often missed when the injury is acute because of swelling and pain. Primary repair of the ruptured tendon is always possible when it is performed within three weeks after the injury. When the diagnosis is in doubt immediately after an injury, the patient should be followed closely and should be reexamined after the swelling and pain have diminished so that treatment can be instituted before the end of this three-week period. Reconstruction of the tendon is a much more complex, challenging procedure, and the postoperative recovery is slower. Thus, we believe that early surgical repair, within three weeks after the injury, is the treatment of choice for distal triceps tendon ruptures. of evidence.

Adult↗

Patellar component resection arthroplasty for the severely compromised patella.

When severe bone loss precludes reimplantation of a new patellar component during revision knee arthroplasty, the treatment options include patellar bone grafting, patellar component resection arthroplasty, and patellectomy. The purpose of this study was to evaluate the clinical and functional results of patellar component resection arthroplasty for the severely compromised patella for which insertion of another patellar component was not possible. Thirty-five knees (31 patients) were treated with patellar component resection arthroplasty for aseptic patellar component failure associated with severely compromised patellar bone stock. Followup averaged 7.9 years (range, 2-18 years). There was a significant improvement in Knee Society pain and function scores. Pain relief was more dramatic than functional improvement. The range of motion also improved significantly and in particular preoperative extensor lag was resolved in the majority of patients. Patients treated with isolated patellar resection arthroplasty were more likely to have continuing pain and require reoperation compared with patients who had concomitant revision of the tibial and femoral components. Correct positioning and the stability of tibial and femoral components should be tested carefully at the time of patellar resection arthroplasty and considered for revision if malpositioned either axially or rotationally.

Adult↗

Importance of a radial head component in Sorbie unlinked total elbow arthroplasty.

The effects of a radial head component on total elbow arthroplasty kinematics and stability were evaluated using an anatomic design unlinked total elbow prosthesis. An electromagnetic tracking device recorded motion and varus and valgus displacements under various conditions in 10 cadaveric elbows. The motion patterns of the intact elbows and the Sorbie-Questor total elbow prostheses with a radial head component were similar, as both tended to have a valgus position in extension, varus at midflexion, and more valgus toward full flexion. Under conditions of simulated muscle loading, the maximum valgus and varus laxity of the elbow prosthesis was, on average, 8.6 degrees +/- 4.0 degrees greater than normal. Without the radial head component, however, significant kinematic disturbances and instabilities were seen. The varus and valgus displacements were 13.3 degrees +/- 5.5 degrees greater than the intact elbows. One total elbow arthroplasty without a radial head dislocated during testing. Increasing the muscle loading across the elbow significantly enhanced dynamic stability of the total elbow arthroplasties, especially in the extension half of elbow motion where instability is greatest. However, this dynamic enhancement of stability was seen only in those elbows in which the radial head component had been implanted. The radial head component is an important stabilizer, particularly in extension for this prosthesis, and possibly for other unlinked total elbow prostheses. Although instability of unlinked prostheses depends on the prosthetic design, the use of a radial head replacement may be an important factor in preventing such instability. Perhaps even more importantly, a radial head component balances the load distribution across the articulation, which could decrease stress on the ulnohumeral articulation and therefore possibly reduce polyethylene wear, osteolysis, and loosening.

Aged↗

Surgical techniques for reconstruction of chronic insufficiency of the triceps. Rotation flap using anconeus and tendo achillis allograft.

Seven patients with chronic insufficiency of the triceps were treated by either a rotation flap using anconeus (4) or an allograft of tendo Achillis (3). The latter procedure was selected for patients with a large defect in whom the anconeus muscle had been devitalised. Five disruptions were in patients who had previously undergone an elbow replacement. The patients were assessed for subjective satisfaction, pain, range of movement and strength, and the results were graded using the Mayo Elbow Performance Score (MEPS). The mean follow-up was for 33 months (9 to 63). One rotation flap failed six months after operation. At the most recent follow-up, the remaining six patients had no or slight pain, restoration of a functional arc of movement and normal or slightly decreased power of extension. All six were satisfied with the outcome and were able to resume their daily activities with no limitations other than those imposed by the previous elbow replacement. The final MEPS was 100 points in five patients and 75 in one.

Achilles Tendon↗

The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty.

BACKGROUND: Despite improvements in the design and manufacturing of the components used in total knee arthroplasty, wear of the polyethylene bearing remains a potential source of failure. One theoretical advantage of modular tibial implants is that, when the components are well fixed, patients with wear or instability of the tibial insert can be treated with isolated polyethylene exchange. The aim of this study was to assess the results of isolated tibial insert exchange during revision surgery in a relatively large, consecutive group of patients. METHODS: From 1985 through 1997, we performed fifty-six isolated tibial insert exchanges in fifty-five patients (twenty-nine men [one man had bilateral revision] and twenty-six women; mean age, sixty-six years) primarily because of wear or instability. Patients with loosening of any of the components, a history of infection, severe stiffness of the knee, recognized malposition of any component, or problems with the extensor mechanism were excluded. Twelve knees had had one, two, or three prior revisions. The duration of follow-up averaged 8.3 years (range, 1.6 to 16.2 years) after the index arthroplasty and 4.6 years (range, two to fourteen years) after the revision. RESULTS: The mean Knee Society knee and function scores improved from 56 and 50.9 points prior to the revision to 76 and 59 points at the time of final follopcow-up. Fourteen (25%) of the fifty-six knees subsequently required rerevision at a mean of only three years (range, 0.5 to 6.8 years) after the tibial insert exchange. The cumulative survival rate at 5.5 years was 63.5% (95% confidence interval, 14.4%, with nineteen patients remaining at risk). Of the twenty-seven knees with preoperative instability, eight were rerevised and another four were considered failures because of severe pain. Of the twenty-four knees that were treated with the index revision because of wear of the insert, five were rerevised. In addition, one extremity in this group was amputated above the knee as a result of chronic osteomyelitis of the ankle concomitant with chronic pain at the site of the total knee arthroplasty and another two inserts were considered failures because of severe pain. CONCLUSIONS: Isolated tibial insert exchange led to a surprisingly high rate of early failure. Tibial insert exchange as an isolated method of total knee revision should therefore be undertaken with caution even in circumstances for which the modular insert was designed and believed to be of greatest value.

Adult↗

Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components.

BACKGROUND: Charnley total hip arthroplasty has been demonstrated to provide good clinical results and a high rate of implant survivorship for twenty years and longer. Most long-term series are not large enough to stratify the many demographic factors that influence implant survivorship. The purpose of this study was to analyze the effects of demographic factors and diagnoses on the long-term survivorship of the acetabular and femoral components used in Charnley total hip arthroplasty. METHODS: Two thousand primary Charnley total hip arthroplasties (1689 patients) were performed at one institution from 1969 to 1971. Patients were contacted at five-year intervals after the arthroplasty. Twenty-five years after the surgery, 1228 patients had died and 461 patients were living. Hips that had not had a reoperation, revision or removal of a component for any reason, or revision or removal for aseptic loosening were considered to have survived. Survivorship data were calculated with use of the method of Kaplan and Meier. Patients were stratified by age, gender, and underlying diagnosis to determine the influence of these factors on implant survivorship. RESULTS: The twenty-five year rates of survivorship free of reoperation, free of revision or removal of the implant for any reason, and free of revision or removal for aseptic loosening were 77.5%, 80.9% and 86.5%, respectively. The twenty-five-year survivorship free of revision for aseptic loosening was poorer for each decade earlier in life at which the procedure was performed; this survivorship ranged from 68.7% for patients who were less than forty years of age to 100% for patients who were eighty years of age or older. Men had a twofold higher rate of revision for aseptic loosening than did women. CONCLUSIONS: Age, gender, and underlying diagnosis all affected the likelihood of long-term survivorship of the acetabular and femoral components used in Charnley total hip arthroplasty.

Acetabulum↗

Operative treatment of elbow contracture in patients twenty-one years of age or younger.

BACKGROUND: Elbow contracture is a recognized sequela of traumatic and developmental elbow disorders, but little information is available regarding the surgical treatment of elbow stiffness in the pediatric population. METHODS: Thirty-seven patients who had had open surgical release of an elbow contracture at a mean age of sixteen years (range, ten to twenty years) were retrospectively studied after a mean duration of follow-up of fifteen months (range, six to forty-four months). The elbow contracture was posttraumatic in twenty-eight patients. The operation consisted of a capsular release with removal of osseous impediments to motion as necessary. No patient had muscle or tendon-lengthening. RESULTS: The total arc of motion improved from a mean of 66 preoperatively to a mean of 94 postoperatively; however, only twenty-eight patients (76%) had an improvement of 10 and only seventeen (46%) achieved a functional arc of motion of 100 (from 30 to 130 ). Two patients lost motion after surgery. These results are less favorable than the results of previous studies of both pediatric and adult patients. Patients in whom the contracture had been caused by a simple dislocation of the elbow or an extra-articular fracture tended to have better results than those in whom the contracture was due to other causes. CONCLUSIONS: The results of surgical treatment of elbow stiffness in pediatric patients are less favorable and less predictable than those in adult patients.

Adolescent↗

Proximal radial resection for posttraumatic radioulnar synostosis: a new technique to improve forearm rotation.

BACKGROUND: Heterotopic ossification about the elbow joint can lead to considerable functional disability, including the loss of forearm rotation. Many procedures have been described for the treatment of proximal radioulnar synostosis. Varying degrees of success have been achieved with regard to the improvement of the flexion arc, but less success has been reported in terms of the restoration of forearm rotation. The success of treatment is associated with the extent of heterotopic ossification, soft-tissue scarring, and anatomical distortion. A new and simple technique to address the unresectable proximal radioulnar synostosis is described. METHODS: Seven patients were managed with a partial proximal radial resection distal to the synostosis and were followed for an average of eighty months (range, twenty-four to 144 months). RESULTS: Forearm rotation improved from an average fixed pronation of 5 degrees to an average arc of 98 degrees (range, 40 degrees to 175 degrees ). The average functional score improved from 57 points preoperatively to 81 points at the time of the final review. Complications included reankylosis at the site of the resection and ulnar-nerve sensory neurapraxia in one patient each. CONCLUSIONS: Resection of a 1-cm-thick section of the proximal part of the radial shaft provides a safe and reliable method of improving forearm rotation in patients with heterotopic ossification of the elbow. A single technical factor that seems to positively influence the result is the application of bone wax at the resection site. This simple procedure is ideally suited for patients who have a proximal radioulnar synostosis that (1) is too extensive to allow a safe and discrete resection, (2) involves the articular surface, and (3) is associated with an anatomical deformity.

Adult↗

Reconstruction of chronic ruptures of the distal biceps tendon with use of an achilles tendon allograft.

BACKGROUND: Chronic ruptures of the distal biceps tendon are uncommon and are complicated by the retraction and poor quality of the muscle and tendon. Surgical procedures that have been described for the treatment of this injury are limited by the quality and availability of the structures used for augmentation. The purpose of the present study was to describe the surgical technique for reconstruction of the tendon with an Achilles tendon allograft and to report our preliminary experience with this procedure. METHODS: An Achilles tendon allograft was used to reconstruct a chronic rupture of the distal biceps tendon in four patients. The patients were evaluated with regard to subjective satisfaction, pain, range of motion, and strength in flexion and supination. The results were graded with use of the Mayo elbow performance score. RESULTS: After an average duration of follow-up of 2.8 years (range, 2.0 to 3.7 years), all four patients had a satisfactory subjective result, a full range of motion, and an excellent Mayo elbow performance score. The strength of flexion and supination was comparable with that on the contralateral side in two patients and was slightly decreased in the other two. CONCLUSIONS: Reconstruction of chronic disruptions of the distal biceps tendon with an Achilles tendon allograft appears to offer a satisfactory technical solution for this challenging problem and has provided satisfactory clinical results to date.

Achilles Tendon↗

Late dislocation after total hip arthroplasty.

BACKGROUND: Some patients have a dislocation for the first time many years after a total hip arthroplasty, but little is known about the risk factors and outcomes associated with late dislocation. The purposes of this study were (1) to determine the prevalence of late dislocation after total hip arthroplasty, (2) to characterize demographic and other factors associated with such late dislocations, and (3) to report the outcomes of such late dislocations. METHODS: Between 1969 and 1995, 19,680 primary total hip arthroplasties were performed in 15,964 patients at our institution. According to a prospective surveillance protocol, the patients were followed routinely at regular intervals and were specifically queried at each time-point about whether (and, if so, when) the hip had dislocated. First dislocations that occurred five years or more after the operation were defined as late dislocations. RESULTS: Five hundred and thirteen (2.6%) of the 19,680 hips dislocated. Of the 513 hips, 165 (0.8% of the entire cohort; 32% of the dislocated hips) first dislocated five or more years after the primary arthroplasty. The median time until the occurrence of these late dislocations was 11.3 years (range, five to 24.9 years) after the operation. Late dislocation was more frequent than early dislocation in women (p = 0.03), and late dislocation was associated with a younger age at the time of the primary total hip arthroplasty (median, sixty-three years) than was early dislocation (median, sixty-seven years) (p = 0.02). Clinical factors associated with late dislocation included previous subluxations without dislocation in twenty patients, a substantial episode of trauma in eleven patients, and onset of marked cognitive or motor neurologic impairment in eleven patients. Radiographically, the late dislocation occurred in association with polyethylene wear of >2 mm in eighteen hips, with implant loosening with migration or a change in position in eight, and with initial malposition of the acetabular implant (anteversion of <0 degrees or >30 degrees or abduction of >55 degrees) in thirty. Late dislocation recurred in ninety (55%) of the 165 hips and was treated with a reoperation in fifty-five hips (33% of the hips with late dislocation; 61% of the hips with recurrent dislocation). CONCLUSIONS: Late dislocation is more common than was previously thought. Several separate processes, some distinct from those associated with early dislocation, can lead to late dislocation. Late dislocation can occur in association with a long-standing problem with the prosthesis that manifests late (such as malposition of the implant or recurrent subluxation), it can occur in association with a new problem (such as neurologic decline, an episode of trauma, or polyethylene wear), or it can occur in association with any combination of these factors. The likelihood of the first late dislocation recurring is high.

Adolescent↗

Ulnohumeral arthroplasty for primary degenerative arthritis of the elbow: long-term outcome and complications.

BACKGROUND: Primary degenerative arthritis of the elbow is an uncommon disorder that recently has been more clearly recognized. The purpose of this study was to analyze the long-term results and complications of ulnohumeral arthroplasty as treatment of primary osteoarthritis of the elbow and to document any tendency for recurrence of the arthritis after the procedure. METHODS: The results of ulnohumeral arthroplasties performed at our institution, between 1986 and 1996, in forty-six elbows (forty-five patients) with primary osteoarthritis were reviewed at an average of eighty months (range, twenty-four to 164 months) after the operation. There were forty-four men and one woman with a mean age of forty-eight years. All patients complained of pain with terminal elbow extension. The pain was associated with locking in fourteen elbows and with ulnar nerve symptoms in twelve. The surgical procedure involved fenestration of the olecranon fossa and excision of olecranon and coronoid osteophytes in all patients, with removal of loose bodies in thirty-six elbows. A capsular release was performed in nineteen elbows, and an ulnar nerve transposition or neurolysis was done in eight. Preoperative and follow-up assessment included evaluation of elbow pain and range of motion with the Mayo Elbow Performance Score. RESULTS: The mean arc of flexion-extension improved from 79 degrees (range, 10 degrees to 135 degrees) preoperatively to 101 degrees (range, 45 degrees to 135 degrees) at the time of follow-up (p < 0.05). At the last follow-up examination, thirty-five elbows (76%) were not painful or were only mildly painful and eleven were moderately or severely painful. According to the Mayo Elbow Performance Score, the result was excellent for twenty-six elbows, good for eight, fair for four, and poor for eight. Thirteen of the forty-five patients reported some degree of ulnar nerve symptoms postoperatively, and six of them required another operation to decompress or translocate the nerve. Two other patients underwent additional surgery because of persistent symptoms. CONCLUSIONS: The data from this study show that ulnohumeral arthroplasty can yield satisfactory long-term pain relief and an increase in the range of motion. Patients with severe preoperative limitation of elbow extension of >60 degrees and flexion of <100 degrees and those who undergo manipulation under anesthesia in the early postoperative period to increase motion are at risk for the development of ulnar nerve dysfunction postoperatively. One should consider prophylactic ulnar nerve decompression or mobilization under these circumstances.

Adult↗

Periprosthetic humeral fractures after total elbow arthroplasty: treatment with implant revision and strut allograft augmentation.

BACKGROUND: Periprosthetic fractures are among the most challenging complications of elbow arthroplasty, and published information about the outcome of treatment is limited. The purpose of the present study was to determine the results of implant revision and strut allograft augmentation for the treatment of humeral periprosthetic fractures that occur around a loose humeral component. METHODS: Between 1991 and 1999, eleven periprosthetic fractures that occurred around a loose humeral component were treated with cortical strut allograft augmentation and revision arthroplasty with use of a Coonrad-Morrey semiconstrained implant. Six fractures occurred after a primary arthroplasty, and five occurred after a revision arthroplasty. Two parallel strut grafts were used for fracture fixation in most cases. Patients were followed for an average of three years (range, nine months to 7.8 years) and were evaluated clinically and radiographically. RESULTS: Clinical and radiographic fracture union was obtained in ten of the eleven patients. One patient required revision surgery because of aseptic loosening of the humeral component seven years and nine months after fracture union; there were no other implant failures. Complications included one additional nondisplaced humeral periprosthetic fracture after surgery that failed to heal with closed treatment, one olecranon fracture, one permanent ulnar nerve injury, and one case of triceps insufficiency. At the time of the most recent follow-up, seven of the eight patients with an intact reconstruction had a functional arc of motion and no or slight pain and one had limited motion and moderate pain. CONCLUSIONS: Periprosthetic humeral fractures that are associated with a loose humeral component can be effectively treated with revision elbow arthroplasty and strut allograft augmentation. The technique is associated with a high rate of fracture union, implant survival, and satisfactory clinical results. However, the complication rate is substantial.

Adult↗