PubMed Health⌕ Search

Biomedical subjects

Bernard Filoche

Publications and source records attributed to Bernard Filoche.

12 recordsLinked to original sources

Acute hepatitis C during the third trimester of pregnancy.

A pregnant woman presented at 32 weeks of amenorrhea with jaundice secondary to acute hepatitis C. Spontaneous delivery took place 3 days later. The infant's serum tested negative for C viral RNA 6 months after delivery. Treatment with high doses of interferon-alpha for a period of 4 weeks was begun 4 days after delivery. Although a virological response was noted at the end of the treatment, the hepatitis relapsed and progressed toward chronicity. Case reports of acute hepatitis C during pregnancy are very rare, as the methods used for the follow-up of pregnant women render the diagnosis of asymptomatic forms difficult. In one case, the acute hepatitis C was severe. The occurrence of acute hepatitis C during pregnancy seems to increase the risk of premature delivery, but not that of vertical transmission. Given the frequency of side effects, it seems preferable not to begin interferon treatment until after delivery.

Acute Disease↗

Does the "Suspected Blood Indicator" improve the detection of bleeding lesions by capsule endoscopy?

BACKGROUND: The "Suspected Blood Indicator" (SBI), a feature included in the software for interpretation of capsule endoscopy (CE), is designed to facilitate detection of bleeding lesions in the small bowel. This study evaluated the sensitivity and the specificity of the SBI in patients who underwent CE for obscure GI bleeding (OGIB). METHODS: CE recordings from patients with OGIB recruited in 7 centers were read by experts blinded to the red SBI tags. They classified lesions of interest as bleeding or as having a potential for bleeding that was high (P2), low (P1), or absent (P0). The SBI tags then were marked by a another investigator. Concordance was acknowledged when frames selected by the expert reader, and those tagged by the SBI had the same time code. RESULTS: A total of 156 recordings were evaluated. In 83, there was either no lesion (n = 71) or a P0 lesion (n = 12); these CE recordings were regarded as normal. Among the 73 abnormal recordings, 114 P2 and 92 P1 lesions were identified. A total of 154 red tags were analyzed. Sensitivity, specificity, and positive and negative predictive values of SBI were 37%, 59%, 50%, and 46%, respectively, for detection of the presence of a P2 or P1 lesion in front of a red tag. CONCLUSIONS: SBI-based detection of intestinal lesions with the potential for bleeding is of limited clinical value in practice and does not reduce the time required for interpretation of CE.

Endoscopes, Gastrointestinal↗

[Crohn's disease associated with interferon and ribavirin treatment for chronic hepatitis C].

Digestive side effects associated with interferon and ribavirin in the treatment of chronic hepatitis C seem to be non specific. So far, inflammatory bowel diseases have only been rarely described in this context. We report two cases of Crohn's disease which occurred a few months after interferon and ribavirin treatment for chronic hepatitis C. The first case was a 43 year old man treated for 7 months with a interferon and ribavirin combination for chronic hepatitis C who experienced colitis related to Crohn's disease, with the occurrence of articular and cutaneous manifestations. The second case was a 43 year old women treated for 8 months with a pegylated interferon and ribavirin combination for chronic hepatitis C who developed Crohn's disease with right ileo-colic topography and severe evolution requiring an ileo-coecal resection because of the failure of medical treatment. The alpha interferon used for its antiviral action against hepatitis C virus, has complex immuno-modulation effects which could reveal latent Crohn's disease.

Adult↗

Interference between pacemaker and video capsule endoscopy.

The wireless capsule video endoscopy is useful in patients with occult blood loss, but is contraindicated in patients with cardiac pacemaker (PM). No case of interference has been published. We report the case of a patient with a PM implanted in the abdominal wall. After capsule ingestion, cardiac monitoring showed no modification of the PM compartment (VOO, unipolar mode) but the capsule recording reveal more than 3 hours of loss of image. The wireless capsule endoscopy is safe in patients with PMs in VOO mode. Nevertheless important interference was noted in the recording when the capsule was near the PM.

Aged↗

[An inter-laboratory study of anti-HCV antibody detection in saliva samples].

AIM: The purpose of this study was to evaluate the efficacy of anti-hepatitis C virus (HCV) antibody detection in the saliva samples of 108 drug users in an inter-laboratory study. METHODS: Between January and June 2001, 108 subjects in Lille, Metz and Lens received a test to detect anti-HCV antibodies in their saliva. Two consecutive saliva samples were taken in each subject (Salivette system, Sarstedt). An HCV serology (Axsym HCV 3.0, Abbott) was also performed and serum HCV RNA detection by Amplicor HCV 2.0 (Roche) was performed when HCV serology was positive. Sixty three patients had a negative HCV serology, 45 had a positive HCV serology, and 31 of these had positive HCV RNA as well. Tests for the detection of the anti HCV antibody in saliva samples were performed as a blind study in both the Lille and the Thionville laboratories. RESULTS: The sensitivity of saliva anti-HCV antibody tests was respectively 71% (32/45) and 78% (35/45) in Lille and Thionville. In the event of positive HCV viremia, the sensitivity was respectively 90% (28/31) and 93% (29/31). The specificity was respectively 97% (61/63) and 98.5% (62/63). Results from the two laboratories agreed for 101 saliva tests while discrepancies were found in 7 (Kappa Concordance Coefficient: 0.85). CONCLUSIONS: This study confirms, in a large, unselected population sample, that anti-HCV antibody detection tests in saliva allow the detection of 90% of viremic HCV-antibody-positive patients with excellent specificity. The simplicity and reproductibility of this technique makes it a precious tool for epidemiological studies.

Hepatitis C Antibodies↗

[Value of endoscopic ultrasonography and somatostatin receptor scintigraphy in the preoperative localization of insulinomas and gastrinomas. Experience of 54 cases].

AIM: The classic morphological techniques for the localization of insulinomas and gastrinomas are of limited value. Endoscopic ultrasonography and somatostatin receptor scintigraphy have shown high sensitivity for the detection of gastroenteropancreatic endocrine tumors. The aim of the study was to evaluate the sensitivity of endoscopic ultrasonography and that of somatostatin receptor scintigraphy in the localization of insulinomas and gastrinomas. PATIENTS AND METHODS: This retrospective study concerned 54 patients with insulinoma (n=29) or gastrinoma (n=26) operated on between March 1991 and March 2000 and who had at least one among the two tested examinations. Forty-two patients had scintigraphy (17 with insulinoma, 25 with gastrinoma), 47 had endoscopic ultrasonography (28 with insulinoma, 17 with gastrinoma). One of the ten patients with MEN 1 had both tumors. All diagnosis were confirmed by histologic examination. RESULTS: The sensitivity of scintigraphy for the localization of insulinomas was 47%. There was one false positive. Sensitivity of endoscopic ultrasonography for insulinomas was 85%. The sensitivity of scintigraphy in the detection of gastrinomas was 65% for the tumors in the duodenopancreatic area, 20% for the tumors in the pancreatic tail and 71% for metastasis. The sensitivity of endoscopic ultrasonography was 46% for duodenal tumors, 75% for pancreatic tumors and 57% for lymph node metastasis. The combination of both localization studies increased sensitivity to 94%. CONCLUSION: Endoscopic ultrasonography and somatostatin receptor scintigraphy are the gold standard for localization of gastrinomas. Association of both examinations increases the sensitivity. Scintigraphy for the detection of insulinomas should be performed when endoscopic ultrasonography is negative.

Adolescent↗